{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RG9001-0AG00","brand":"Siemens","brandSlug":"siemens","productSlug":"3RG9001-0AG00","canonicalUrl":"https://aoctrl.com/siemens/3RG9001-0AG00","factsUrl":"https://aoctrl.com/api/mcp/products/3RG9001-0AG00","rawCanonicalId":null},"summary":{"shortDescription":"Siemens AS-Interface user module, 4 digital inputs, PNP, IP67, M12 screw terminals, 20-30 VDC.","salesMarkdown":"## What the 4 DI means for an AS-i drop The Siemens 3RG9001-0AG00 is a 4-input AS-Interface user module — four PNP digital inputs, zero outputs, drawing up to 250 mA from the AS-i bus. The 20-30 VDC input range and 10 V high-level threshold mean it accepts standard 24 V sensor signals without a separate field supply. With the AS-i protocol on the bus, the module ID code is 0, so the master identifies it as a standard 4-input slave. ## IP67 field deployment and wiring Rated IP67, the module is built for direct machine-mount installation — no enclosure needed on the line. The four M12 screw-terminated sockets (D0–D3) accept 2- or 3-wire sensors. Mounts via standard rail or wall-mount using the coupling module; dimensions are 45 x 80 x 27 mm (W/H/D). ## Lifecycle status — phased out, sourced per RFQ This module is a phased-out product — EOL hot status per Siemens.","metaTitle":"Siemens 3RG9001-0AG00 AS-i User Module, 4 DI, IP67","metaDescription":"Siemens 3RG9001-0AG00 AS-Interface user module, 4 digital inputs, PNP, IP67, M12 connections. Phased-out product — sourced to order against an RFQ. 20-30 VDC.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLC I/O & Expansion Modules"],"specifications":{"Type":"4 inputs","Depth":"27mm","Width":"45mm","title":"3RG9001-0AG00","Height":"80mm","Socket":"input (D0)","ID code":"0","Socket 2":"input (D1)","Socket 3":"input (D2)","Socket 4":"input (D3)","Connection":"using contact pins on FK or Pg coupling module","description":"AS Interface user module IP67 Phased-out product!!! For further information, please contact our sales department digital, 4 DI 4x 1 input, max. 200 mA PNP 4 x M12 socket","Input Voltage":"20 ... 30V","Input circuit":"PNP","During Storage":"-40 ... +85°C","display of I/Os":"yellow LED","lifecycle_stage":"eol_hot","During Operation":"-25 ... +85°C","Fastening Method":"standard rail mounting/wall mounting using coupling module","I/O configuration":"0","Number I/O sockets":"4","protection class IP":"IP67","Design Of The Product":"digital I/O modules for operation in the field, IP67 - user modules","For Signal <1> Minimum":"5mA","With Signal <0> Maximum":"1.5mA","Design Of The Slave Type":"standard slave","Number Of Digital Inputs":"4","Number Of Digital Outputs":"0","Type Of Connection Technology":"2- and 3-wire technology","Inputs switching level High min":"10V","display of AS-Interface/diagnostics":"green LED","AS interface total current input max":"250mA","Type Of Voltage Of The Input Voltages":"DC","reference code according to EN 61346-2":"K","Inputs sensor supply using AS-Interface":"short-circuit and overload resistant","Design Of The Pin Assignment Of The Inputs":"standard assignement","Property Of The Output Short-Circuit Proof":"No","Design Of The Pin Assignment Of The Outputs":"standard assignement","protocol is supported AS-Interface protocol":"Yes","Type Of Electrical Connection Of The Inputs And Outputs":"M12 screw-type terminals","operating voltage according to AS-Interface spezification":"26.5 ... 31.6V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d613544f924cd3e29bdb53a44fadaf6a.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=410554&mlfb=3RG9001-0AG00"},"ai":{"faq":[{"question":"Is the Siemens 3RG9001-0AG00 still available?","answer":"The 3RG9001-0AG00 is a phased-out product."},{"question":"What are the specifications of 3RG9001-0AG00?","answer":"The 3RG9001-0AG00 is a 4-input AS-Interface user module with PNP inputs, 20-30 VDC operating voltage, IP67 rating, and M12 screw-type connections. It draws up to 250 mA from the AS-i bus and has an ID code of 0."},{"question":"Where can I buy 3RG9001-0AG00?","answer":"The 3RG9001-0AG00 is a phased-out product. Submit an RFQ — we source it through independent distribution and confirm availability and pricing at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RG9001-0AG00","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RG9001-0AG00 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}