{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RG9004-0DA00","brand":"Siemens","brandSlug":"siemens","productSlug":"3RG9004-0DA00","canonicalUrl":"https://aoctrl.com/siemens/3RG9004-0DA00","factsUrl":"https://aoctrl.com/api/mcp/products/3RG9004-0DA00","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3RG9004-0DA00, AS-Interface F90 module, 4 digital inputs / 4 solid-state outputs, IP20, 35 mm DIN-rail mount, end-of-life.","salesMarkdown":"## What the 4-in/4-out split means on a live line The 3RG9004-0DA00 is a 4-input / 4-output AS-Interface F90 module — a standard slave (ID/ID2 code 0/F) that fits a 35 mm DIN rail inside an IP20 control cabinet. The four PNP inputs (switching level high min 10 V) connect to 2- or 3-wire sensors; the four solid-state outputs sink a combined 6 A total, but each output circuit needs its own 20–30 V DC auxiliary supply (PELV, Class III) via the Combicon plug connector. The AS-Interface cable itself powers the module logic and sensor supply (short-circuit and overload resistant), but the output power comes from that separate 24 V feed — a common trip point for integrators who assume the bus handles everything. ## Current budget and the external supply catch The module draws up to 270 mA from the AS-Interface bus for its own logic and sensor feed. The 6 A total output current comes entirely from the external 24 V DC supply — if that supply is missing or undersized, the outputs sit dead regardless of the bus state. Each output is short-circuit protected and has built-in induction protection, so a downstream solenoid or contactor coil does not need a separate flyback diode. The input side draws 5 mA minimum at signal <1> and max 1.5 mA at signal <0>. The sensor supply from the AS-Interface is short-circuit and overload resistant, which means a shorted sensor lead does not take down the whole module — just that channel. ## End-of-life status and sourcing path This module is end-of-life (EOL).","metaTitle":"Siemens 3RG9004-0DA00 AS-Interface Module, 4 In/4 Out, EOL","metaDescription":"Siemens 3RG9004-0DA00 AS-Interface module, 4 digital inputs / 4 outputs, IP20, DIN-rail. End-of-life status; sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Digital Output Modules"],"specifications":{"D0":"IN1/OUT1","D1":"IN2/OUT2","D2":"IN3/OUT3","D3":"IN4/OUT4","Type":"4 inputs / 4 outputs","Depth":"37mm","Width":"90mm","title":"3RG9004-0DA00","Height":"75mm","Note 1":"An external additional supply (AUX POWER) of 20 to 30 V DC is required for the supply of the output circuits. The additional supply must comply with VDE 0106 (PELV), protection class III.","Watchdog":"built-in","Addressing":"possible using integrated addressing socket","ID/ID2 code":"0/F","description":"AS-Interface module F90, digital 4 DI/4 DQ, IP20 4 x inputs for 3-wire sensor 4 x output, 2 A, 24 V DC maximal 6 A for all outputs Connection via Combicon Width 90 mm Combicon connector set 3RX9810-0AA00 must be ordered.","Input circuit":"PNP transistor","During Storage":"-40 ... +85°C","display of I/Os":"yellow LEDs","lifecycle_stage":"eol_hot","During Operation":"-25 ... +70°C","Fastening Method":"35 mm standard rail mounting","I/O configuration":"7","Connection Sensors":"2- and 3-conductor technology","protection class IP":"IP20","Induction Protection":"built-in","Design Of The Product":"F90 module - I/O modules for operation in the control cabinet, IP20","For Signal <1> Minimum":"5mA","Short-Ciruit Protection":"built-in","With Signal <0> Maximum":"1.5mA","Design Of The Slave Type":"standard slave","Number Of Digital Inputs":"4","Type Of Switching Output":"solid state","switching level High min":"10V","Number Of Digital Outputs":"4","Type Of Connection Technology":"2- and 3-conductor PNP transistor","sensor supply using AS-Interface":"short-circuit and overload resistant","Type Of Voltage Of Output Voltages":"DC","display of AS-Interface/diagnostics":"green/red dual LED","AS interface total current input max":"270mA","Outputs total current of all outputs":"6A","Outputs external power supply 24 V DC":"using Combicon plug connector","Type Of Voltage Of The Input Voltages":"DC","Type Of Voltage Supply For Power Supply":"using AS-Interface","Property Of The Output Short-Circuit Proof":"Yes","Type Of Electrical Connection Of The Inputs And Outputs":"combicon connection","operating voltage according to AS-Interface spezification":"26.5 ... 31.6V","Output Current At Digital Output For Signal <1> Rated Value":"2A","Property Of The Sensor Supply Short-Circuit And Overload Resistant":"Yes","ampacity of the sensor supply for all inputs at ambient temperature 40 °C":"200mA"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/39fef249c0fec9a8ff58b2e078cf46fd.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1999&mlfb=3RG9004-0DA00"},"ai":{"faq":[{"question":"Is 3RG9004-0DA00 obsolete?","answer":"Yes, the Siemens 3RG9004-0DA00 is end-of-life (EOL). No official replacement order code has been published. Sourcing is through independent distribution on a quoted-to-order basis."},{"question":"Does 3RG9004-0DA00 require an auxiliary power supply?","answer":"Yes. The output circuits require an external 20–30 V DC auxiliary supply (PELV, Class III) connected via the Combicon plug connector. The AS-Interface bus powers the module logic and sensor supply, but not the outputs."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RG9004-0DA00","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RG9004-0DA00 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}