{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RH1122-2BN40","brand":"Siemens","brandSlug":"siemens","productSlug":"3RH1122-2BN40","canonicalUrl":"https://aoctrl.com/siemens/3RH1122-2BN40","factsUrl":"https://aoctrl.com/api/mcp/products/3RH1122-2BN40","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS auxiliary contactor, size S00, 3RH1122-2BN40, 10 A AC-12 rated, 250 V, screw and snap-on mounting, IP20 front.","salesMarkdown":"The Siemens SIRIUS 3RH1122-2BN40 is a size S00 auxiliary contactor rated for 10 A at AC-12 duty (resistive load) up to 250 V. That AC-12 rating means it's built for switching resistive loads like heaters or control transformers — not motor starts. The coil holds at 3.2 W DC, making it compatible with standard 24 VDC PLC outputs without a separate power supply. The 45 mm width (three 17.5 mm modules) fits standard panel layouts. IP20 on the front is standard for enclosed panels; no washdown rating here. ## Ratings and switching capacity Rated operational current varies by voltage: 10 A at 24 V, 6 A at 230 V, 3 A at 400 V, 2 A at 500 V, 1 A at 690 V. The DC switching curve drops faster: 1 A at 110 V, 0.27 A at 220 V.","metaTitle":"Siemens SIRIUS 3RH1122-2BN40 Auxiliary Contactor, Size S00,","metaDescription":"Siemens SIRIUS 3RH1122-2BN40 auxiliary contactor, size S00, rated 10 A AC-12 at 250 V. Active production. Screw and snap-on mounting. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"45 mm","Height":"60 mm","Rated Value":"250 V","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Leading Contact":"0","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","During Transport":"-55 ... +80 °C","Fastening Method":"screw and snap-on mounting","Full-Scale Value":"1.1","Shock Resistance":"10g / 5 ms and 5g / 10 ms","Delayed Switching":"0","Lagging Switching":"0","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Product Brand Name":"SIRIUS","Contact Reliability":"one incorrect switching operation of 100 million switching operations (17 V, 1 mA)","Degree Of Pollution":"3","Product Designation":"Auxiliary contactor","at 24 V rated value":"10 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.27 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 500 V rated value":"2 A","at 690 V rated value":"1 A","Instantaneous Contact":"2","For Auxiliary Contacts":"0","Make-Before-Break Switching":"0","Substance Prohibitance (Date)":"07/01/2006","protection class IP on the front":"IP20","Product Extension Auxiliary Switch":"Yes","closing power of magnet coil at DC":"3.2 W","holding power of magnet coil at DC":"3.2 W","Surge Voltage Resistance Rated Value":"6 kV","operational current at AC-12 maximum":"10 A","for AWG cables for auxiliary contacts":"2x (24 ... 14)","reference code according to IEC 81346-2":"K","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Touch Protection Against Electrical Shock":"finger-safe","with low demand rate according to SN 31920":"40 %","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","Of Auxiliary Contacts Instantaneous Contact":"0","with high demand rate according to SN 31920":"75 %","number of NC contacts for auxiliary contacts":"2","number of NO contacts for auxiliary contacts":"2","Type Of Voltage Of The Control Supply Voltage":"DC","Identification Number And Letter For Switching Elements":"22 E","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Required Spacing With Side-By-Side Mounting At The Side":"0 mm","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Type Of Electrical Connection For Auxiliary And Control Circuit":"Cage Clamp terminals","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000","Design Of The Fuse Link For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=179064&mlfb=3RH1122-2BN40","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RH1122-2BN40/alternatives.json"},"ai":{"faq":[{"question":"What is the closest functional alternative to 3RH1122-2BN40?","answer":"The 3RH2122-1BW40 is a size S00 auxiliary contactor in the same SIRIUS family. The key difference is the coil voltage: the 3RH1122-2BN40 uses a 24 VDC coil (3.2 W holding), while the 3RH2122-1BW40 may use a different coil voltage — check your control voltage before substituting. Physical footprint and mounting are the same, so it drops into the same panel without rewiring."},{"question":"Where can I buy 3RH1122-2BN40?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What compliance documentation does 3RH1122-2BN40 carry?","answer":"RoHS compliant per the July 1, 2006 directive. The SIRIUS series typically carries UL, CSA, and CE approvals; specific certification marks are listed in the manufacturer's datasheet."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RH1122-2BN40","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RH1122-2BN40 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}