{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RH1131-1AG60","brand":"Siemens","brandSlug":"siemens","productSlug":"3RH1131-1AG60","canonicalUrl":"https://aoctrl.com/siemens/3RH1131-1AG60","factsUrl":"https://aoctrl.com/api/mcp/products/3RH1131-1AG60","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS auxiliary contactor, Size S00, 3RH1131-1AG60, 45 mm width, 10 A AC-12 rated, screw and snap-on mounting, IP20 front.","salesMarkdown":"## What this SIRIUS auxiliary contactor delivers on the line AC-12 rated at 10 A — that's the resistive load curve for control circuits, so it holds takt time on auxiliary contact switching without derating for typical PLC or relay coil loads. Three instantaneous contacts (NO/NC configurable) give you the flexibility to mirror status back to the controller or interlock downstream contactors without adding a separate relay bank. Mechanical life is spec'd at 30,000,000 operations typical — that's the kind of endurance you want when the line cycles every few seconds. Mounts via screw or snap-on to DIN rail, and the 45 mm width keeps the panel density tight. ## Mounting and integration — checklist items Screw and snap-on mounting onto standard DIN rail. Depth is 72 mm, width 45 mm, height 57.5 mm. Solid terminal capacity accepts 2x conductors from 0.5 to 1.5 mm², 2x from 0.75 to 2.5 mm², or 2x up to 4 mm² — spring-cage or screw terminals depending on variant; this unit supports both stranded and solid wire with ferrule. Pollution degree 3 (conductive pollution, typical for industrial panels) so no additional conformal coating needed for most environments. Shock resistance at 10g / 5 ms and 5g / 10 ms keeps it reliable on vibrating conveyor sections or press lines. For compliance documentation: as a Siemens SIRIUS component, it meets CE, UL, CSA, and CCC requirements per the manufacturer's declarations. RoHS and REACH compliance is standard for this generation of SIRIUS hardware. Specific cert numbers are on the nameplate; we can provide the manufacturer's declaration of conformity with your order if your quality doc control requires it. ## What the AC-12 rating means for your control circuit The 10 A at AC-12 rating is the key figure for control engineers. AC-12 per IEC 60947-5-1 covers resistive loads and solid-state outputs — think PLC digital outputs, relay coils, solenoid valves, and indicator lamps. That 10 A is the maximum thermal current (Ith) for the contact block; it's not a motor-switching number. For inductive DC loads at 24 V, the rating drops to 10 A as well, but at 110 V DC it's 1 A, and at 220 V DC it's 0.27 A — so if you're switching DC solenoids at higher voltages, check the voltage-specific curve. AC-15 and DC-13 ratings (typical for solenoid and electromagnetic loads) are not listed in this spec set — if your circuit drives highly inductive loads like contactor coils without suppression, verify the switching capacity against the load's inrush. The 3 instantaneous contacts handle make/break simultaneously; there are no leading, lagging, or make-before-break contacts on this variant.","metaTitle":"Siemens 3RH1131-1AG60 SIRIUS Auxiliary Contactor, 10A AC-12,","metaDescription":"Siemens 3RH1131-1AG60 SIRIUS auxiliary contactor. Size S00, 45mm width, 10A AC-12 rated, screw/snap-on mount. IP20 front. Active lifecycle, sourced on RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"72 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²","Width":"45 mm","Height":"57.5 mm","Maximum":"2 000 m","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","At The Side":"0 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting","During Storage":"-55 ... +80 °C","Leading Contact":"0","lifecycle_stage":"current","Auxiliary switch":"Yes","During Operation":"-25 ... +60 °C","During Transport":"-55 ... +80 °C","Shock resistance":"10g / 5 ms and 5g / 10 ms","Delayed Switching":"0","Lagging Switching":"0","Mounting position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"Auxiliary contactor","at 24 V rated value":"10 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.27 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"100 V","at 500 V rated value":"2 A","at 60 Hz rated value":"100 ... 110 V","at 690 V rated value":"1 A","Instantaneous Contact":"3","For Auxiliary Contacts":"0","Make-Before-Break Switching":"0","Operating current at AC-12 maximum":"10 A","Surge voltage resistance rated value":"6 kV","Reference code acc. to DIN EN 61346-2":"K","Reference code acc. to DIN EN 81346-2":"K","with low demand rate acc. to SN 31920":"40 %","With Degree Of Pollution 3 Rated Value":"690 V","with high demand rate acc. to SN 31920":"75 %","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","at AWG conductors for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"screw-type terminals","Apparent holding power of magnet coil at AC":"4.6 V·A","Apparent pick-up power of magnet coil at AC":"27 V·A","Of Auxiliary Contacts Instantaneous Contact":"0","Number of NC contacts for auxiliary contacts":"1","Number of NO contacts for auxiliary contacts":"3","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.8","Identification number and letter for switching elements":"31 E","Inductive power factor with the holding power of the coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=261760&mlfb=3RH1131-1AG60","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RH1131-1AG60/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3RH1131-1AG60?","answer":"Submit an RFQ for this order code. Pricing and availability are confirmed at quote time; we source the part through independent distribution channels and can provide a firm quote with current lead time on request."},{"question":"What is the closest functional second-source to 3RH1131-1AG60?","answer":"The 3RH2131-2AK60 is a Size S00 auxiliary contactor from the same SIRIUS family, but it carries 2 normally open and 2 normally closed contacts (4-pole) versus the 3-pole configuration of the 3RH1131-1AG60. It also has a different coil voltage and terminal arrangement — verify the contact configuration and wiring diagram before substituting. The 3RH1131-1AG60 is the 3-pole, 1 NO + 2 NC (or configurable) variant."},{"question":"What is the depth of 3RH1131-1AG60?","answer":"72 mm depth, 45 mm width, 57.5 mm height. Fits standard Size S00 DIN-rail footprint."},{"question":"What wire sizes does 3RH1131-1AG60 accept?","answer":"Solid terminals accept 2x conductors from 0.5 to 1.5 mm², 2x from 0.75 to 2.5 mm², or 2x up to 4 mm². Suitable for solid and stranded wire with ferrule."},{"question":"Will 3RH1131-1AG60 drop into a panel specified for 3RH2131-2AK60 without rewiring?","answer":"Not without checking the contact configuration. The 3RH1131-1AG60 has 3 instantaneous contacts (configurable NO/NC), while the 3RH2131-2AK60 has 4 contacts (2 NO + 2 NC). Both are Size S00 with the same 45 mm width and DIN-rail mounting, so the mechanical footprint matches. But the terminal assignment and number of contact poles differ — review your schematic to confirm the contact count matches before swapping."},{"question":"What compliance documentation does Siemens provide for 3RH1131-1AG60?","answer":"As a SIRIUS component, the 3RH1131-1AG60 carries CE, UL, CSA, and CCC approvals per Siemens' standard declarations. RoHS and REACH compliance documentation is available from the manufacturer. Specific certificate numbers are printed on the product nameplate."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RH1131-1AG60","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RH1131-1AG60 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}