{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RH1131-2KF40","brand":"Siemens","brandSlug":"siemens","productSlug":"3RH1131-2KF40","canonicalUrl":"https://aoctrl.com/siemens/3RH1131-2KF40","factsUrl":"https://aoctrl.com/api/mcp/products/3RH1131-2KF40","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RH1131-2KF40 coupling relay, size S00, 110 V DC coil, 3 NO contacts, screw and snap-on mounting, IP20 front.","salesMarkdown":"The Siemens 3RH1131-2KF40 is a SIRIUS coupling relay designed for switching auxiliary circuits in control panels. It carries three instantaneous normally-open (NO) contacts and a 110 V DC coil. The size S00 footprint (45 mm wide, 60 mm tall, 73 mm deep) fits standard DIN-rail enclosures alongside contactors of the same frame class. A built-in varistor suppresses the switching surge across the coil, which extends the life of downstream PLC outputs driving it. Rated for pollution degree 3, this relay handles the conductive-dust and humidity conditions typical of industrial control cabinets without conformal coating. The contact ratings are given per voltage, not as a single blanket ampacity. At 24 V it switches 10 A; at 110 V it switches 1 A; at 230 V it switches 6 A; at 400 V it switches 3 A; at 500 V it switches 2 A; at 690 V it switches 1 A. These are thermal current ratings (Ith) for AC loads — the actual make/break capability for inductive DC loads will be lower. For a 110 V DC control circuit, the 1 A rating is the hard limit; don't assume the 10 A at 24 V carries over. Contact reliability is specified as one incorrect switching operation per 100 million cycles at 17 V, 1 mA. That's the low-energy switching floor — if your circuit runs dry contacts at logic levels, this relay will hold up. The mechanical life of the contactor typical is 30 million operations, so the electrical endurance at rated load will be the limiting factor in high-cycle applications. Wire termination accepts 2x (0.25 to 2.5 mm²) solid or stranded conductors — no ferrule required for solid wire, but stranded should use ferrules for reliable cage-clamp grip. Shock resistance is rated at 10g for 5 ms and 5g for 10 ms, which covers most industrial vibration environments short of direct hammer-mill mounting.","metaTitle":"Siemens 3RH1131-2KF40 SIRIUS Coupling Relay, 110 V coil, 3 N","metaDescription":"Siemens SIRIUS 3RH1131-2KF40 coupling relay for auxiliary circuits. 110 V DC coil, 3 instantaneous NO contacts, size S00. IP20 front. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":[],"specifications":{"Depth":"73 mm","Width":"45 mm","Height":"60 mm","Mounting":"screw and snap-on mounting","Product Status":"Active"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2873c911d7139bae349729e209f4efb7.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=93827&mlfb=3RH1131-2KF40","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RH1131-2KF40/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RH1131-2KF40","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RH1131-2KF40 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}