{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RH1140-1AV00","brand":"Siemens","brandSlug":"siemens","productSlug":"3RH1140-1AV00","canonicalUrl":"https://aoctrl.com/siemens/3RH1140-1AV00","factsUrl":"https://aoctrl.com/api/mcp/products/3RH1140-1AV00","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS auxiliary contactor, 3RH1140-1AV00, size S00, 4 NO instantaneous contacts, 10 A AC-12 rated, screw and snap-on mounting, IP20 front.","salesMarkdown":"The headline rating is 10 A at AC-12 (resistive loads at 24 V), which is the maximum continuous current the contacts can carry in that duty class. For inductive switching at higher voltages, the rated current drops: 6 A at 230 V, 3 A at 400 V, 1 A at 690 V — so the actual load determines whether this contactor holds up. The 4 NO configuration means it can switch four independent control circuits simultaneously, typical for signaling, interlocking, or extending the auxiliary contacts of a larger power contactor. The solid wire capacity accepts 2x 0.5–1.5 mm², 2x 0.75–2.5 mm², or 2x 4 mm² — enough for most control wiring without needing ferrules, though ferruled stranded is also fine.","metaTitle":"Siemens 3RH1140-1AV00 SIRIUS Auxiliary Contactor, 4 NO, S00,","metaDescription":"Siemens 3RH1140-1AV00 SIRIUS auxiliary contactor, size S00, 4 NO instantaneous contacts, 10 A AC-12, screw/snap-on mounting, IP20 front. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"72 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²","Width":"45 mm","Height":"57.5 mm","Maximum":"2 000 m","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","At The Side":"0 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting","During Storage":"-55 ... +80 °C","Leading Contact":"0","lifecycle_stage":"current","Auxiliary switch":"Yes","During Operation":"-25 ... +60 °C","During Transport":"-55 ... +80 °C","Shock resistance":"10g / 5 ms and 5g / 10 ms","Delayed Switching":"0","Lagging Switching":"0","Mounting position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"Auxiliary contactor","at 24 V rated value":"10 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.27 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"400 V","at 500 V rated value":"2 A","at 60 Hz rated value":"400 V","at 690 V rated value":"1 A","Instantaneous Contact":"4","For Auxiliary Contacts":"0","Make-Before-Break Switching":"0","Operating current at AC-12 maximum":"10 A","Surge voltage resistance rated value":"6 kV","Reference code acc. to DIN EN 61346-2":"K","Reference code acc. to DIN EN 81346-2":"K","with low demand rate acc. to SN 31920":"40 %","With Degree Of Pollution 3 Rated Value":"690 V","with high demand rate acc. to SN 31920":"75 %","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","at AWG conductors for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"screw-type terminals","Apparent holding power of magnet coil at AC":"4.6 V·A","Apparent pick-up power of magnet coil at AC":"27 V·A","Of Auxiliary Contacts Instantaneous Contact":"0","Number of NC contacts for auxiliary contacts":"0","Number of NO contacts for auxiliary contacts":"4","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.8","Identification number and letter for switching elements":"40 E","Inductive power factor with the holding power of the coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$25.08","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=485358&mlfb=3RH1140-1AV00","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RH1140-1AV00/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RH1140-1AV00 and how do I get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time."},{"question":"What is the contact configuration of 3RH1140-1AV00?","answer":"It has 4 normally-open (NO) instantaneous contacts. There are no delayed, lagging, or make-before-break contacts."},{"question":"What is the rated operational current at AC-12?","answer":"The maximum operating current at AC-12 is 10 A. For inductive loads at higher voltages, derate per the switching capacity table: 6 A at 230 V, 3 A at 400 V, 1 A at 690 V."},{"question":"What mounting options does 3RH1140-1AV00 support?","answer":"It supports both screw fixing and snap-on mounting onto a DIN rail. The mounting position allows ±180° rotation on a vertical surface and ±22.5° tilt forward/backward."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RH1140-1AV00","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RH1140-1AV00 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}