{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RH1140-1BB40-0TK0-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RH1140-1BB40-0TK0-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RH1140-1BB40-0TK0-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RH1140-1BB40-0TK0-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS, auxiliary contactor, 3RH1140-1BB40-0TK0-ZX95, 4 NO, 24 V DC coil, size S00, IP20 front, screw and snap-on mounting.","salesMarkdown":"Rated mechanical endurance is 30 million operations, with contact reliability of one incorrect switching per 100 million at 17 V, 1 mA. The IP20 front protection suits enclosed control panels; pollution degree 3 covers industrial environments with conductive pollution. For switching loads, the contact ratings vary by voltage: 10 A at 24 V, 6 A at 230 V, 3 A at 400 V, 2 A at 500 V, and 1 A at 690 V. The 6 kV surge voltage resistance ensures coordination with upstream surge protection in industrial panels. Terminals accept solid conductors: 2x 0.5–1.5 mm², 2x 0.75–2.5 mm², and 2x 4 mm² (or AWG equivalents 2x 20–16, 2x 18–14, 1x 12). The clamping range covers most control wiring gauges used in panel builds. Depth is 72 mm, width 45 mm, height 57.5 mm — compact enough for dense DIN-rail layouts. Fastening is screw or snap-on onto a DIN rail — no adapter needed. The size S00 body fits standard 45 mm wide slots. Shock resistance rated 10g / 5 ms and 5g / 10 ms.","metaTitle":"Siemens 3RH1140-1BB40-0TK0-ZX95 SIRIUS Auxiliary Contactor,","metaDescription":"Siemens SIRIUS 3RH1140-1BB40-0TK0-ZX95 auxiliary contactor, 24 V DC coil, 4 NO contacts, size S00. IP20 front, screw/snap-on mount. Active production, quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"72 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²","Width":"45 mm","Height":"57.5 mm","Rated Value":"24 V","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Leading Contact":"0","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","During Transport":"-55 ... +80 °C","Fastening Method":"screw and snap-on mounting","Full-Scale Value":"1.1","Shock Resistance":"10g / 5 ms and 5g / 10 ms","Delayed Switching":"0","Lagging Switching":"0","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Product Brand Name":"SIRIUS","Contact Reliability":"one incorrect switching operation of 100 million switching operations (17 V, 1 mA)","Degree Of Pollution":"3","Product Designation":"Auxiliary contactor","at 24 V rated value":"10 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.27 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 500 V rated value":"2 A","at 690 V rated value":"1 A","Instantaneous Contact":"4","For Auxiliary Contacts":"0","Make-Before-Break Switching":"0","Substance Prohibitance (Date)":"07/01/2006","protection class IP on the front":"IP20","Product Extension Auxiliary Switch":"Yes","closing power of magnet coil at DC":"3.2 W","holding power of magnet coil at DC":"3.2 W","Surge Voltage Resistance Rated Value":"6 kV","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","operational current at AC-12 maximum":"10 A","reference code according to IEC 81346-2":"K","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Touch Protection Against Electrical Shock":"finger-safe","with low demand rate according to SN 31920":"40 %","Of Auxiliary Contacts Instantaneous Contact":"0","with high demand rate according to SN 31920":"75 %","number of NC contacts for auxiliary contacts":"0","number of NO contacts for auxiliary contacts":"4","Type Of Voltage Of The Control Supply Voltage":"DC","Identification Number And Letter For Switching Elements":"40 E","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Required Spacing With Side-By-Side Mounting At The Side":"0 mm","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Type Of Electrical Connection For Auxiliary And Control Circuit":"screw-type terminals","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000","Design Of The Fuse Link For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=47387&mlfb=3RH1140-1BB40-0TK0-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RH1140-1BB40-0TK0-ZX95/alternatives.json"},"ai":{"faq":[{"question":"What is the closest functional second-source to 3RH1140-1BB40-0TK0-ZX95?","answer":"The 3RH2140-1BP40 is a peer auxiliary contactor in the same SIRIUS family, but it uses a different coil voltage and contact arrangement — verify your control voltage and contact count before substituting. The 3RH1140-1BB40-0TK0-ZX95 is a 24 V DC, 4 NO configuration; the 3RH2140-1BP40 differs in coil and contact specs."},{"question":"Where can I buy 3RH1140-1BB40-0TK0-ZX95?","answer":"Sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for your volume."},{"question":"What compliance documentation does 3RH1140-1BB40-0TK0-ZX95 have?","answer":"RoHS compliance date is July 1, 2006, covering substance prohibitions. The part carries IP20 front protection and pollution degree 3 rating. Surge voltage resistance is 6 kV."},{"question":"Will 3RH1140-1BB40-0TK0-ZX95 drop into a panel specified around 3RH2140-1BP40 without rewiring?","answer":"Both are size S00 with the same DIN-rail footprint, so mechanical fit is the same. However, the coil voltage and contact configuration differ — verify your control circuit voltage and NO/NC count before swapping."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RH1140-1BB40-0TK0-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RH1140-1BB40-0TK0-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}