{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RH1262-2AP00","brand":"Siemens","brandSlug":"siemens","productSlug":"3RH1262-2AP00","canonicalUrl":"https://aoctrl.com/siemens/3RH1262-2AP00","factsUrl":"https://aoctrl.com/api/mcp/products/3RH1262-2AP00","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS auxiliary contactor, size S00, 6 NO instantaneous contacts, 230 V AC 50/60 Hz coil, screw and snap-on mounting, IP20 front.","salesMarkdown":"It carries six instantaneous normally-open (NO) contacts, rated for switching control circuits and signal loads up to 10 A in AC-12 duty. The front face carries IP20 finger protection; the rest of the enclosure is open to the panel environment, so install it inside a cabinet with a door. The coil is rated 230 V AC at both 50 Hz and 60 Hz, with an operating range of 0.8...1.1 × rated voltage at 50 Hz and 0.85...1.1 at 60 Hz — meaning the coil will pick up reliably as low as 184 V at 50 Hz and 195.5 V at 60 Hz, and hold in through a 10% overvoltage. Contact ratings are given per voltage class: 10 A at 24 V, 6 A at 230 V, 3 A at 400 V, 2 A at 500 V, and 1 A at 690 V. These are the thermal continuous currents the contacts can carry in AC-12 (resistive control) service. For inductive loads or DC switching, derate per the manufacturer's curves — the 690 V / 1 A rating gives a sense of the arc-quenching limit at higher voltages. The six contacts are all instantaneous (no delayed, leading, lagging, or make-before-break variants) — they close and open together with the armature. ## Environmental and installation limits Shock resistance is 10 g / 5 ms and 5 g / 10 ms, adequate for most rotating machinery and conveyor applications but not rated for high-g impact environments. Terminals accept solid conductors from 0.25 to 2.5 mm² (2 × that range per clamp).","metaTitle":"Siemens 3RH1262-2AP00 SIRIUS Auxiliary Contactor, 6 NO, 230V","metaDescription":"Siemens SIRIUS 3RH1262-2AP00 auxiliary contactor, 6 instantaneous NO contacts, 230V 50/60Hz coil, size S00. Current production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"114 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"45 mm","Height":"60 mm","Maximum":"2 000 m","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","At The Side":"0 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting","During Storage":"-55 ... +80 °C","Leading Contact":"0","lifecycle_stage":"current","Auxiliary switch":"No","During Operation":"-25 ... +60 °C","During Transport":"-55 ... +80 °C","Shock resistance":"10g / 5 ms and 5g / 10 ms","Delayed Switching":"0","Lagging Switching":"0","Mounting position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"Auxiliary contactor","at 24 V rated value":"10 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.27 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"230 V","at 500 V rated value":"2 A","at 60 Hz rated value":"230 V","at 690 V rated value":"1 A","Instantaneous Contact":"6","For Auxiliary Contacts":"0","Make-Before-Break Switching":"0","Operating current at AC-12 maximum":"10 A","Surge voltage resistance rated value":"6 kV","Reference code acc. to DIN EN 61346-2":"K","Reference code acc. to DIN EN 81346-2":"K","with low demand rate acc. to SN 31920":"40 %","With Degree Of Pollution 3 Rated Value":"690 V","with high demand rate acc. to SN 31920":"75 %","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","at AWG conductors for auxiliary contacts":"2x (24 ... 14)","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"Cage Clamp terminals","Apparent holding power of magnet coil at AC":"4.6 V·A","Apparent pick-up power of magnet coil at AC":"27 V·A","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","Of Auxiliary Contacts Instantaneous Contact":"0","Number of NC contacts for auxiliary contacts":"2","Number of NO contacts for auxiliary contacts":"6","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.8","Identification number and letter for switching elements":"62 E","Inductive power factor with the holding power of the coil":"0.27","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=40086&mlfb=3RH1262-2AP00","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RH1262-2AP00/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RH1262-2AP00 and get a price?","answer":"This part is sourced to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability — no stock or price figures are published here."},{"question":"Will 3RH1262-2AP00 drop into a panel specified around 3RH2362-2AF00?","answer":"Both are SIRIUS size S00 auxiliary contactors with the same 45 mm width and DIN-rail mounting, so the mechanical footprint is identical. The key difference is contact configuration: 3RH1262-2AP00 carries 6 NO instantaneous contacts, while 3RH2362-2AF00 carries a different contact arrangement (check its NO/NC count). If your circuit requires the exact contact set of the 3RH2362-2AF00, verify the NO/NC count before substitution — the panel cutout and wiring path will fit either."},{"question":"What compliance documentation is available for 3RH1262-2AP00?","answer":"As a Siemens SIRIUS product, it carries CE marking for the European market and is manufactured under IEC/EN 60947-5-1 for control circuit devices. UL and CSA listings are typical for the SIRIUS family, but specific certification marks for this order code should be confirmed from the nameplate or the manufacturer's declaration of conformity."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RH1262-2AP00","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RH1262-2AP00 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}