{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RH1362-1UB40-0KV0-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RH1362-1UB40-0KV0-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RH1362-1UB40-0KV0-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RH1362-1UB40-0KV0-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS auxiliary contactor, 24 V DC coil, size S00, 45 mm width, screw and snap-on mounting, IP20 front protection.","salesMarkdown":"It carries a 24 V DC coil, with a closing and holding power of 3.2 W — a steady-state draw that a standard 24 V DC power supply handles without issue. ## Terminal capacity and contact configuration The terminal block accepts solid conductors: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), and 2x 4 mm². That covers most control wiring gauges you'd run in a panel — no need for ferrule adapters on the 4 mm² runs. The contact arrangement provides 6 instantaneous contacts (NO/NC configurable per the base device), with no leading, lagging, delayed, or make-before-break switching options on this variant. For a straightforward interlock or feedback circuit, that's sufficient; if you need sequenced contact timing, you'd look at the optional auxiliary switch block (not included here). Shock resistance is rated at 10g for 5 ms and 5g for 10 ms.","metaTitle":"Siemens 3RH1362-1UB40-0KV0-ZX95 SIRIUS Auxiliary Contactor,","metaDescription":"Siemens SIRIUS 3RH1362-1UB40-0KV0-ZX95 auxiliary contactor, 24 V DC coil, size S00, 45 mm wide, screw and snap-on mounting. Current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"111 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²","Width":"45 mm","Height":"57.5 mm","Rated Value":"24 V","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Leading Contact":"0","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","During Transport":"-55 ... +80 °C","Fastening Method":"screw and snap-on mounting","Full-Scale Value":"1.1","Shock Resistance":"10g / 5 ms and 5g / 10 ms","Delayed Switching":"0","Lagging Switching":"0","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Product Brand Name":"SIRIUS","Contact Reliability":"one incorrect switching operation of 100 million switching operations (17 V, 1 mA)","Degree Of Pollution":"3","Product Designation":"Auxiliary contactor","at 24 V rated value":"10 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.27 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 500 V rated value":"2 A","at 690 V rated value":"1 A","Instantaneous Contact":"6","For Auxiliary Contacts":"0","Make-Before-Break Switching":"0","Substance Prohibitance (Date)":"07/01/2006","Design Of The Surge Suppressor":"with varistor","protection class IP on the front":"IP20","Product Extension Auxiliary Switch":"No","closing power of magnet coil at DC":"3.2 W","holding power of magnet coil at DC":"3.2 W","Surge Voltage Resistance Rated Value":"6 kV","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","operational current at AC-12 maximum":"10 A","reference code according to IEC 81346-2":"K","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Touch Protection Against Electrical Shock":"finger-safe","with low demand rate according to SN 31920":"40 %","Of Auxiliary Contacts Instantaneous Contact":"0","with high demand rate according to SN 31920":"75 %","number of NC contacts for auxiliary contacts":"2","number of NO contacts for auxiliary contacts":"6","Type Of Voltage Of The Control Supply Voltage":"DC","Identification Number And Letter For Switching Elements":"62 E","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Required Spacing With Side-By-Side Mounting At The Side":"0 mm","Type Of Electrical Connection For Auxiliary And Control Circuit":"screw-type terminals","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Design Of The Fuse Link For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=17464&mlfb=3RH1362-1UB40-0KV0-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RH1362-1UB40-0KV0-ZX95/alternatives.json"},"ai":{"faq":[{"question":"What are the key dimensions for panel layout?","answer":"Width is 45 mm, height is 57.5 mm, depth is 111 mm. The size S00 footprint fits standard DIN-rail spacing alongside other SIRIUS contactors and overload relays."},{"question":"What wire sizes does the terminal block accept?","answer":"Solid conductors: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), and 2x 4 mm². No ferrule requirement for the 4 mm² runs."},{"question":"What is the coil voltage and power draw?","answer":"Rated coil voltage is 24 V DC. Closing and holding power is 3.2 W DC, so a standard 24 V DC power supply with adequate headroom will drive it."},{"question":"Will this drop into a panel designed for a 3RT1015-1BB42?","answer":"The 3RH1362 is an auxiliary contactor (size S00, 45 mm wide), while the 3RT1015 is a power contactor. Both share the S00 footprint and snap-on DIN-rail mounting, so the physical fit is the same. However, the coil voltage (24 V DC vs the 3RT1015-1BB42's 24 V DC) and contact configuration differ — verify your control circuit wiring before swapping."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RH1362-1UB40-0KV0-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RH1362-1UB40-0KV0-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}