{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RH1362-2AG10","brand":"Siemens","brandSlug":"siemens","productSlug":"3RH1362-2AG10","canonicalUrl":"https://aoctrl.com/siemens/3RH1362-2AG10","factsUrl":"https://aoctrl.com/api/mcp/products/3RH1362-2AG10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS auxiliary contactor, size S00, 6 NO instantaneous contacts, 10 A AC-12, 45 mm width, IP20, screw and snap-on mounting.","salesMarkdown":"The Siemens 3RH1362-2AG10 is a SIRIUS auxiliary contactor in size S00, carrying six normally-open instantaneous contacts rated for AC-12 duty at 10 A maximum. It is designed to extend the signal-contact count on a contactor or motor starter — common in control panels where a single main contactor needs more auxiliary feedback or interlock paths than its built-in contacts provide. The 45 mm width and screw-and-snap-on mounting mean it clips directly onto a DIN rail alongside the main contactor, saving panel space vs. a terminal-block solution. The AC-12 rating of 10 A covers resistive and solid-state loads at 24 V — the most common control-circuit voltage in industrial panels. At higher voltages the current drops: 6 A at 230 V, 3 A at 400 V, and 1 A at 690 V. If your circuit runs at 110 V, the contact is rated for 1 A. The 6 kV surge-voltage rating (impulse withstand) means it coordinates with standard IEC 60947-1 control-circuit isolation levels. Pollution degree 3 confirms it holds up in the conductive-dust environment typical of a panel near a production line, not just a clean room. That low-level reliability matters for PLC-input dry circuits — the silver alloy contacts handle the low energy without oxidation buildup. The front face is IP20, so finger-safe once the panel door is closed but not rated for washdown. Shock resistance is 10g for 5 ms and 5g for 10 ms, covering most vibration from adjacent contactors or motor starters on the same rail. Wire termination accepts 2x (0.25 to 2.5 mm²) solid or stranded, or 2x (24 to 14 AWG).","metaTitle":"Siemens 3RH1362-2AG10 SIRIUS Auxiliary Contactor, 6 NO, S00,","metaDescription":"Siemens SIRIUS 3RH1362-2AG10 auxiliary contactor, size S00, 6 NO contacts, 10A AC-12, 45mm wide, IP20, screw/snap-on mount. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"114 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"45 mm","Height":"60 mm","at 60 Hz":"0.85 ... 1.1","1 Rated Value":"60 Hz","During Storage":"-55 ... +80 °C","Leading Contact":"0","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","During Transport":"-55 ... +80 °C","Fastening Method":"screw and snap-on mounting","Shock Resistance":"10g / 5 ms and 5g / 10 ms","Delayed Switching":"0","Lagging Switching":"0","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Product Brand Name":"SIRIUS","Contact Reliability":"one incorrect switching operation of 100 million switching operations (17 V, 1 mA)","Degree Of Pollution":"3","Product Designation":"Auxiliary contactor","at 24 V rated value":"10 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.27 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"100 V","at 500 V rated value":"2 A","at 60 Hz rated value":"110 V","at 690 V rated value":"1 A","Instantaneous Contact":"6","For Auxiliary Contacts":"0","Make-Before-Break Switching":"0","Substance Prohibitance (Date)":"07/01/2006","protection class IP on the front":"IP20","Product Extension Auxiliary Switch":"No","Surge Voltage Resistance Rated Value":"6 kV","operational current at AC-12 maximum":"10 A","for AWG cables for auxiliary contacts":"2x (24 ... 14)","reference code according to IEC 81346-2":"K","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Touch Protection Against Electrical Shock":"finger-safe","with low demand rate according to SN 31920":"40 %","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","Of Auxiliary Contacts Instantaneous Contact":"0","apparent holding power of magnet coil at AC":"4.6 VA","apparent pick-up power of magnet coil at AC":"27 VA","with high demand rate according to SN 31920":"75 %","number of NC contacts for auxiliary contacts":"2","number of NO contacts for auxiliary contacts":"6","Type Of Voltage Of The Control Supply Voltage":"AC","Inductive Power Factor With Closing Power Of The Coil":"0.8","Identification Number And Letter For Switching Elements":"62 E","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Required Spacing With Side-By-Side Mounting At The Side":"0 mm","Inductive Power Factor With The Holding Power Of The Coil":"0.27","Type Of Electrical Connection For Auxiliary And Control Circuit":"Cage Clamp terminals","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Design Of The Fuse Link For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=324588&mlfb=3RH1362-2AG10","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RH1362-2AG10/alternatives.json"},"ai":{"faq":[{"question":"What is the closest functional second-source for 3RH1362-2AG10?","answer":"The 3RH2362-2AF00 is a functional peer in the same SIRIUS family, but it carries a different contact configuration — verify the NO/NC count and coil voltage against your schematic before substituting. The 3RH1362-2AG10 is a 6 NO instantaneous-contact variant."},{"question":"What compliance documentation does Siemens provide for 3RH1362-2AG10?","answer":"The part carries a RoHS compliance date of July 1, 2006, covering the EU RoHS directive. As a SIRIUS component, it is designed to meet IEC 60947-1 and IEC 60947-5-1 standards for control-circuit devices. UL and CSA listings are standard for the SIRIUS line; confirm the specific file numbers with the factory datasheet."},{"question":"What is 3RH1362-2AG10's depth?","answer":"The listed depth is 114 mm. Combined with the 45 mm width and 60 mm height, it occupies a standard S00 contactor footprint on the DIN rail."},{"question":"Where can I buy 3RH1362-2AG10?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for your required quantity."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RH1362-2AG10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RH1362-2AG10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}