{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RH1362-2BB40-ZW95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RH1362-2BB40-ZW95","canonicalUrl":"https://aoctrl.com/siemens/3RH1362-2BB40-ZW95","factsUrl":"https://aoctrl.com/api/mcp/products/3RH1362-2BB40-ZW95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS auxiliary contactor, size S00, 24 VDC coil, 6 NO instantaneous contacts, rated 10 A at 24 V, screw and snap-on mounting, IP20 front protection.","salesMarkdown":"The Siemens 3RH1362-2BB40-ZW95 is a SIRIUS auxiliary contactor — size S00, with six normally-open instantaneous contacts and a 24 VDC coil. It's the part you reach for when you need to multiply control signals from a PLC output or a larger contactor's auxiliary block, not switch main motor current. The coil pulls 3.2 W on DC, both closing and holding, so it's a steady load on a 24 VDC supply. The contact ratings are given per voltage point, not a single blanket figure: 10 A at 24 V, 6 A at 230 V, 3 A at 400 V, 2 A at 500 V, 1 A at 690 V. That's the thermal current the contacts can handle in AC-15 or DC-13 duty — use the voltage that matches your control circuit. The 6 kV rated surge voltage resistance (impulse withstand) means it's coordinated for standard 400 V industrial panels without extra suppression. Contact reliability is spec'd at one incorrect switching operation per 100 million cycles at 17 V, 1 mA — that's the low-energy end, where oxide films on silver contacts can cause trouble. For dry-contact PLC inputs or low-voltage signal switching, this part is built to not ghost. That covers most panel layouts without derating. Terminal capacity is 2x (0.25 to 2.5 mm²) solid or stranded, or 2x (24 to 14 AWG) for the auxiliary contacts — standard control wiring, no special ferrules needed.","metaTitle":"Siemens 3RH1362-2BB40-ZW95 SIRIUS Auxiliary Contactor, 24 VD","metaDescription":"Siemens SIRIUS auxiliary contactor 3RH1362-2BB40-ZW95, size S00, 24 VDC coil, 6 NO contacts, rated 10 A at 24 V. IP20 front, screw and snap-on mounting. Active production, sourced","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"114 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"45 mm","Height":"60 mm","Rated Value":"24 V","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Leading Contact":"0","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","During Transport":"-55 ... +80 °C","Fastening Method":"screw and snap-on mounting","Full-Scale Value":"1.1","Shock Resistance":"10g / 5 ms and 5g / 10 ms","Delayed Switching":"0","Lagging Switching":"0","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Product Brand Name":"SIRIUS","Contact Reliability":"one incorrect switching operation of 100 million switching operations (17 V, 1 mA)","Degree Of Pollution":"3","Product Designation":"Auxiliary contactor","at 24 V rated value":"10 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.27 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 500 V rated value":"2 A","at 690 V rated value":"1 A","Instantaneous Contact":"6","For Auxiliary Contacts":"0","Make-Before-Break Switching":"0","Substance Prohibitance (Date)":"07/01/2006","protection class IP on the front":"IP20","Product Extension Auxiliary Switch":"No","closing power of magnet coil at DC":"3.2 W","holding power of magnet coil at DC":"3.2 W","Surge Voltage Resistance Rated Value":"6 kV","at AWG cables for auxiliary contacts":"2x (24 ... 14)","operational current at AC-12 maximum":"10 A","reference code according to IEC 81346-2":"K","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Touch Protection Against Electrical Shock":"finger-safe","with low demand rate according to SN 31920":"40 %","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","Of Auxiliary Contacts Instantaneous Contact":"0","with high demand rate according to SN 31920":"75 %","number of NC contacts for auxiliary contacts":"2","number of NO contacts for auxiliary contacts":"6","Type Of Voltage Of The Control Supply Voltage":"DC","Identification Number And Letter For Switching Elements":"62 E","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Required Spacing With Side-By-Side Mounting At The Side":"0 mm","Type Of Electrical Connection For Auxiliary And Control Circuit":"Cage Clamp terminals","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Design Of The Fuse Link For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=387650&mlfb=3RH1362-2BB40-ZW95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RH1362-2BB40-ZW95/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RH1362-2BB40-ZW95 and get a price?","answer":"This part is sourced and quoted to order through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time, no stock count or price figure on this page."},{"question":"What is the depth of 3RH1362-2BB40-ZW95?","answer":"The listed depth is 114 mm, with a width of 45 mm and height of 60 mm — fits the standard S00 contactor footprint on DIN rail."},{"question":"What wire sizes does the 3RH1362-2BB40-ZW95 accept?","answer":"The auxiliary contact terminals accept 2x (0.25 to 2.5 mm²) solid or stranded, or 2x (24 to 14 AWG). Standard control wiring, no special ferrules required."},{"question":"Will 3RH1362-2BB40-ZW95 drop into a panel specified around 3RH2362-2AF00 without rewiring?","answer":"Both are SIRIUS size S00 auxiliary contactors with the same DIN-rail footprint and terminal capacity. The 3RH1362-2BB40-ZW95 carries a 24 VDC coil and 6 NO contacts; the 3RH2362-2AF00 has a different coil voltage and contact arrangement. Panel fit is the same, but verify the coil voltage and contact count against your schematic before swapping."},{"question":"What compliance documentation does Siemens provide for 3RH1362-2BB40-ZW95?","answer":"The part carries a RoHS substance prohibition date of July 1, 2006, indicating compliance with the original RoHS directive. Standard Siemens SIRIUS documentation includes CE declaration and UL/CSA file listings; consult the product datasheet or your Siemens representative for the specific certificate bundle."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RH1362-2BB40-ZW95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RH1362-2BB40-ZW95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}