{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RH1362-2BW40-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RH1362-2BW40-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RH1362-2BW40-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RH1362-2BW40-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS auxiliary contactor, size S00, 3RH1362-2BW40-ZX95, 48 V DC coil, 6 NO instantaneous contacts, screw and snap-on mounting, IP20 front protection, 45 x 60 x 114 mm.","salesMarkdown":"## Panel fit and contact configuration It carries six normally-open (NO) instantaneous contacts and zero NC, make-before-break, or delayed-switching contacts — so it functions purely as a signal multiplier or interposing relay bank, not a sequencing element. The 114 mm depth fits standard enclosures; the 60 mm height leaves room for a second tier of terminals above a busbar trunk. The coil is rated 48 V DC, with a closing and holding power of 3.2 W — a continuous-duty magnet that stays cool enough for dense panel layouts but draws enough to need a properly sized DC supply (a 24 V supply won't pull it in). Contact ratings are given for AC-12 duty (resistive loads, control circuits): 10 A at 24 V, 6 A at 230 V, 3 A at 400 V, 2 A at 500 V, and 1 A at 690 V. These are the maximum continuous currents the contacts can make and carry — not motor-switching (AC-3) figures, so size this for signal-level or small resistive loads only. ## Environmental and compliance data Shock resistance is 10g / 5 ms and 5g / 10 ms, and the mounting position allows ±180° rotation on a vertical surface plus ±22.5° tilt forward/backward — flexible for tight enclosures or angled subpanels. Terminals accept solid or stranded conductors from 0.25 to 2.5 mm² (2x per clamp), which covers standard control wiring up to 14 AWG. Substance prohibitance date is July 1, 2006 — consistent with RoHS compliance; the part carries no product extension auxiliary switch option.","metaTitle":"Siemens 3RH1362-2BW40-ZX95 SIRIUS Auxiliary Contactor, 48 V","metaDescription":"Siemens SIRIUS 3RH1362-2BW40-ZX95 auxiliary contactor, size S00, 48 V DC coil, 6 NO contacts, IP20, screw/snap-on mount, 45 mm wide. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"114 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"45 mm","Height":"60 mm","Rated Value":"48 V","Initial Value":"0.8","During Storage":"-55 ... +80 °C","Leading Contact":"0","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","During Transport":"-55 ... +80 °C","Fastening Method":"screw and snap-on mounting","Full-Scale Value":"1.1","Shock Resistance":"10g / 5 ms and 5g / 10 ms","Delayed Switching":"0","Lagging Switching":"0","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Product Brand Name":"SIRIUS","Contact Reliability":"one incorrect switching operation of 100 million switching operations (17 V, 1 mA)","Degree Of Pollution":"3","Product Designation":"Auxiliary contactor","at 24 V rated value":"10 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.27 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 500 V rated value":"2 A","at 690 V rated value":"1 A","Instantaneous Contact":"6","For Auxiliary Contacts":"0","Make-Before-Break Switching":"0","Substance Prohibitance (Date)":"07/01/2006","protection class IP on the front":"IP20","Product Extension Auxiliary Switch":"No","closing power of magnet coil at DC":"3.2 W","holding power of magnet coil at DC":"3.2 W","Surge Voltage Resistance Rated Value":"6 kV","operational current at AC-12 maximum":"10 A","for AWG cables for auxiliary contacts":"2x (24 ... 14)","reference code according to IEC 81346-2":"K","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Touch Protection Against Electrical Shock":"finger-safe","with low demand rate according to SN 31920":"40 %","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","Of Auxiliary Contacts Instantaneous Contact":"0","with high demand rate according to SN 31920":"75 %","number of NC contacts for auxiliary contacts":"2","number of NO contacts for auxiliary contacts":"6","Type Of Voltage Of The Control Supply Voltage":"DC","Identification Number And Letter For Switching Elements":"62 E","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Required Spacing With Side-By-Side Mounting At The Side":"0 mm","Type Of Electrical Connection For Auxiliary And Control Circuit":"Cage Clamp terminals","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Design Of The Fuse Link For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=317762&mlfb=3RH1362-2BW40-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RH1362-2BW40-ZX95/alternatives.json"},"ai":{"faq":[{"question":"What is the closest functional second-source for 3RH1362-2BW40-ZX95?","answer":"The closest functional sibling is 3RH2362-2AF00, which shares the S00 frame size and 6 NO contact configuration but differs in coil voltage and terminal arrangement — verify coil voltage compatibility before substituting, as the 3RH1362-2BW40-ZX95 uses a 48 V DC coil."},{"question":"Will 3RH1362-2BW40-ZX95 drop into a panel specified around 3RH2362-2AF00 without rewiring?","answer":"Mechanically yes — both are S00 size with screw and snap-on DIN rail mounting, same 45 mm width. Electrically no if the coil voltage differs: the 3RH1362-2BW40-ZX95 requires 48 V DC, while the 3RH2362-2AF00 may use a different coil rating. Check the existing circuit's control voltage before swapping."},{"question":"What compliance documentation does Siemens provide for 3RH1362-2BW40-ZX95?","answer":"The part carries a substance prohibitance date of July 1, 2006, consistent with RoHS compliance. Standard Siemens documentation includes the declaration of conformity and CE marking; specific UL or IEC certification details should be confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RH1362-2BW40-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RH1362-2BW40-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}