{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RH1362-2GG20","brand":"Siemens","brandSlug":"siemens","productSlug":"3RH1362-2GG20","canonicalUrl":"https://aoctrl.com/siemens/3RH1362-2GG20","factsUrl":"https://aoctrl.com/api/mcp/products/3RH1362-2GG20","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RH1362-2GG20 auxiliary contactor, size S00, 6 NO instantaneous contacts, screw and snap-on mounting, rated 10 A at 24 V, 6 A at 230 V, 3 A at 400 V.","salesMarkdown":"It's the part you add to a contactor or a contactor assembly when you need more signal feedback or control interlocks — no coil, no main power path, just reliable contact switching for your PLC inputs, status lamps, or safety chain. Rated 10 A at 24 V, 6 A at 230 V, and 3 A at 400 V, these contacts handle the typical control-circuit loads you'll find in a panel: pilot devices, relay coils, and indicator circuits. The mechanical life of 10 million operations means it'll outlast most of the machines it's wired into. ## Mounting and wiring reality The 45 mm width and 114 mm depth are standard for the size; plan for that in your duct and gland-plate layout. IP20 front protection. ## Where it works","metaTitle":"Siemens 3RH1362-2GG20 SIRIUS Auxiliary Contactor, 6 NO, 24 V","metaDescription":"Siemens SIRIUS 3RH1362-2GG20 auxiliary contactor, 6 NO contacts, rated 10 A at 24 V, 6 A at 230 V. S00 size, screw/snap-on mount. Current production. Request a quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"114 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"45 mm","Height":"60 mm","Maximum":"2 000 m","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","At The Side":"0 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting","During Storage":"-55 ... +80 °C","Leading Contact":"0","lifecycle_stage":"current","Auxiliary switch":"No","During Operation":"-25 ... +60 °C","During Transport":"-55 ... +80 °C","Shock resistance":"10g / 5 ms and 5g / 10 ms","Delayed Switching":"0","Lagging Switching":"0","Mounting position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"Auxiliary contactor","at 24 V rated value":"10 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.27 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"110 V","at 500 V rated value":"2 A","at 60 Hz rated value":"110 V","at 690 V rated value":"1 A","Instantaneous Contact":"6","For Auxiliary Contacts":"0","Make-Before-Break Switching":"0","Design of the surge suppressor":"with full-wave rectification","Operating current at AC-12 maximum":"10 A","Surge voltage resistance rated value":"6 kV","Reference code acc. to DIN EN 61346-2":"K","Reference code acc. to DIN EN 81346-2":"K","with low demand rate acc. to SN 31920":"40 %","with high demand rate acc. to SN 31920":"75 %","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","at AWG conductors for auxiliary contacts":"2x (24 ... 14)","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"Cage Clamp terminals","Apparent holding power of magnet coil at AC":"4.6 V·A","Apparent pick-up power of magnet coil at AC":"27 V·A","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","Of Auxiliary Contacts Instantaneous Contact":"0","Number of NC contacts for auxiliary contacts":"2","Number of NO contacts for auxiliary contacts":"6","with degree of pollution 3 at AC rated value":"690 V","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.8","Identification number and letter for switching elements":"62 E","Inductive power factor with the holding power of the coil":"0.27","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=158449&mlfb=3RH1362-2GG20","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RH1362-2GG20/alternatives.json"},"ai":{"faq":[{"question":"What is the depth of 3RH1362-2GG20?","answer":"114 mm."},{"question":"What conductor sizes does the 3RH1362-2GG20 accept?","answer":"Solid conductors from 0.25 to 2.5 mm², two conductors per terminal."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RH1362-2GG20","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RH1362-2GG20 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}