{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RH1380-2AF00-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RH1380-2AF00-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RH1380-2AF00-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RH1380-2AF00-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS auxiliary contactor, 3RH1380-2AF00-ZX95, size S00, 8 instantaneous NO contacts, 10 A at 24 V, screw and snap-on mounting, IP20 front protection.","salesMarkdown":"The Siemens 3RH1380-2AF00-ZX95 is a SIRIUS auxiliary contactor, size S00, carrying 8 instantaneous normally-open contacts rated 10 A at 24 V. It is a current-production part (lifecycle stage: current) used to switch control signals, pilot devices, and PLC outputs in a panel — not a main power contactor, but the relay that tells the main contactor what to do. The 8 NO contacts are all instantaneous — no leading, lagging, delayed, or make-before-break switching here. That means every contact closes at the same time when the coil picks up, which simplifies timing in a safety circuit or interlock string. The size S00 footprint is the smallest Siemens contactor frame: 45 mm wide, 60 mm tall, 114 mm deep. Terminal capacity accepts 2x (0.25... 2.5 mm²) solid or stranded wire — standard for control wiring. Strip length is not given here, but 8 mm is typical for this terminal family.","metaTitle":"Siemens 3RH1380-2AF00-ZX95 SIRIUS Auxiliary Contactor, 8 NO,","metaDescription":"Siemens SIRIUS 3RH1380-2AF00-ZX95 auxiliary contactor, 8 instantaneous NO contacts, 10 A at 24 V, size S00, IP20, screw/snap-on mount, RoHS compliant. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"114 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"45 mm","Height":"60 mm","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","During Storage":"-55 ... +80 °C","Leading Contact":"0","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","During Transport":"-55 ... +80 °C","Fastening Method":"screw and snap-on mounting","Shock Resistance":"10g / 5 ms and 5g / 10 ms","Delayed Switching":"0","Lagging Switching":"0","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Product Brand Name":"SIRIUS","Contact Reliability":"one incorrect switching operation of 100 million switching operations (17 V, 1 mA)","Degree Of Pollution":"3","Product Designation":"Auxiliary contactor","at 24 V rated value":"10 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.27 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"110 V","at 500 V rated value":"2 A","at 60 Hz rated value":"110 V","at 690 V rated value":"1 A","Instantaneous Contact":"8","For Auxiliary Contacts":"0","Make-Before-Break Switching":"0","Substance Prohibitance (Date)":"07/01/2006","protection class IP on the front":"IP20","Product Extension Auxiliary Switch":"No","Surge Voltage Resistance Rated Value":"6 kV","at AWG cables for auxiliary contacts":"2x (24 ... 14)","operational current at AC-12 maximum":"10 A","reference code according to IEC 81346-2":"K","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Touch Protection Against Electrical Shock":"finger-safe","with low demand rate according to SN 31920":"40 %","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","Of Auxiliary Contacts Instantaneous Contact":"0","apparent holding power of magnet coil at AC":"4.6 VA","apparent pick-up power of magnet coil at AC":"27 VA","with high demand rate according to SN 31920":"75 %","number of NC contacts for auxiliary contacts":"0","number of NO contacts for auxiliary contacts":"8","Type Of Voltage Of The Control Supply Voltage":"AC","Inductive Power Factor With Closing Power Of The Coil":"0.8","Identification Number And Letter For Switching Elements":"80 E","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Required Spacing With Side-By-Side Mounting At The Side":"0 mm","Inductive Power Factor With The Holding Power Of The Coil":"0.27","Type Of Electrical Connection For Auxiliary And Control Circuit":"Cage Clamp terminals","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Design Of The Fuse Link For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=463703&mlfb=3RH1380-2AF00-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RH1380-2AF00-ZX95/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RH1380-2AF00-ZX95 and get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is the closest functional alternative to 3RH1380-2AF00-ZX95?","answer":"The 3RH2362-2AF00 is a peer in the same SIRIUS family but carries a different contact configuration (typically 4 NO + 4 NC vs the 8 NO on this part). Verify your circuit needs — if you require all normally-open contacts, the 3RH1380-2AF00-ZX95 is the correct choice; the 3RH2362-2AF00 will not drop in without rewiring."},{"question":"What compliance documentation does this part have?","answer":"RoHS compliance is confirmed with a substance prohibition date of July 1, 2006. The part carries IP20 front protection and is rated for pollution degree 3. Standard Siemens documentation includes the datasheet and declaration of conformity for the SIRIUS series."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RH1380-2AF00-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RH1380-2AF00-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}