{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RH1921-1LA11","brand":"Siemens","brandSlug":"siemens","productSlug":"3RH1921-1LA11","canonicalUrl":"https://aoctrl.com/siemens/3RH1921-1LA11","factsUrl":"https://aoctrl.com/api/mcp/products/3RH1921-1LA11","rawCanonicalId":null},"summary":{"shortDescription":"Auxiliary switch block, 1 NO + 1 NC, EN 50005 2-pole, screw terminal, for motor contactors, cable entry at the top! Phased-out product! Successor is SIRIUS 3RH2","salesMarkdown":null,"metaTitle":"3RH1921-1LA11","metaDescription":"Auxiliary switch block, 1 NO + 1 NC, EN 50005 2-pole, screw terminal, for motor contactors, cable entry at the top! Phased-out product! Successor is SIRIUS 3RH2","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Note":"with 3RT1","Depth":"51 mm","Width":"44 mm","Height":"38 mm","Maximum":"10 A","at 24 V":"6 A","at 60 V":"2 A","at 110 V":"1 A","at 125 V":"6 A","at 220 V":"0.3 A","at 230 V":"6 A","at 250 V":"6 A","at 400 V":"3 A","During Storage":"-55 ... +80 °C","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"snap-on mounting","Product Brand Name":"SIRIUS","Suitability For Use":"Contactor relay and power contactor","at 24 V rated value":"10 A","at 60 V rated value":"4.7 A","at 110 V rated value":"3 A","at 220 V rated value":"1.2 A","at 440 V rated value":"0.5 A","at 600 V rated value":"0.26 A","Instantaneous Contact":"1","With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","at AC-15 at 690 V rated value":"1 A","protection class IP on the front":"IP20","Surge Voltage Resistance Rated Value":"6 kV","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Mechanical Service Life (Switching Cycles) Typical":"10 000 000","Type Of Electrical Connection For Auxiliary And Control Circuit":"screw-type terminals","insulation voltage with degree of pollution 3 at AC rated value":"690 V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=339136&mlfb=3RH1921-1LA11","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RH1921-1LA11/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RH1921-1LA11","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RH1921-1LA11 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}