{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RH2122-1AE00","brand":"Siemens","brandSlug":"siemens","productSlug":"3RH2122-1AE00","canonicalUrl":"https://aoctrl.com/siemens/3RH2122-1AE00","factsUrl":"https://aoctrl.com/api/mcp/products/3RH2122-1AE00","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RH2122-1AE00 auxiliary contactor, size S00, 10 A at 24 V AC and 230 V AC, screw and snap-on mounting on 35 mm DIN rail, 73 mm depth, 45 mm width, 57.5 mm height.","salesMarkdown":"## Switching ratings and contact performance The 3RH2122-1AE00: Rated 10 A at both 24 V AC and 230 V AC, the contactor handles control-circuit loads typical for PLC outputs, relay coils, and signal switching. The mechanical life is typically 30 million cycles, making it suitable for high-cycle applications like conveyor interlocks or machine-tool control circuits. ## Environmental and compliance specs Pollution degree 3 per IEC 60947-1 means it tolerates conductive dust and condensation in control panels without conformal coating. The part carries a substance prohibition date of 10/01/2009 for RoHS compliance, and the SIRIUS series typically includes CE, UL, and CSA certifications — confirm the specific declaration of conformity for your jurisdiction at RFQ.","metaTitle":"Siemens 3RH2122-1AE00 SIRIUS Auxiliary Contactor, 10 A","metaDescription":"Siemens 3RH2122-1AE00 SIRIUS auxiliary contactor, size S00, rated 10 A at 24 V and 230 V AC. Active production, screw and snap-on DIN rail mount.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Width":"45 mm","at AC":"4 ... 15 ms","at DC":"10 000 1/h","Height":"57.5 mm","Upwards":"10 mm","Forwards":"10 mm","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"6 mm","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","During Storage":"-55 ... +80 °C","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"Auxiliary contactor","at 24 V rated value":"10 A","at 60 V rated value":"4.7 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"3 A","at 220 V rated value":"1.2 A","at 230 V rated value":"10 A","at 400 V rated value":"3 A","at 440 V rated value":"0.5 A","at 50 Hz rated value":"60 V","at 500 V rated value":"2 A","at 60 Hz rated value":"60 V","at 600 V rated value":"0.26 A","at 690 V rated value":"1 A","Instantaneous Contact":"2","Relative Humidity Minimum":"10 %","Substance Prohibitance (Date)":"10/01/2009","Product Extension Auxiliary Switch":"Yes","Surge Voltage Resistance Rated Value":"6 kV","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 2x 12","operating frequency at DC-12 maximum":"1 000 1/h","operating frequency at DC-13 maximum":"1 000 1/h","operational current at AC-12 maximum":"10 A","reference code according to IEC 81346-2":"K","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","with low demand rate according to SN 31920":"40 %","apparent holding power of magnet coil at AC":"5.7 VA","apparent pick-up power of magnet coil at AC":"37 VA","with high demand rate according to SN 31920":"73 %","number of NC contacts for auxiliary contacts":"2","number of NO contacts for auxiliary contacts":"2","Type Of Voltage Of The Control Supply Voltage":"AC","contact rating of auxiliary contacts according to UL":"A600 / Q600","Inductive Power Factor With Closing Power Of The Coil":"0.8","Identification Number And Letter For Switching Elements":"22 E","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Inductive Power Factor With The Holding Power Of The Coil":"0.25","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Type Of Electrical Connection For Auxiliary And Control Circuit":"screw-type terminals","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000","Design Of The Fuse Link For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 V":"C characteristic: 6 A; 0.4 kA"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a22ced0d4415545cfe6651b7ff644258.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=913062&mlfb=3RH2122-1AE00","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RH2122-1AE00/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation does Siemens provide for 3RH2122-1AE00 (RoHS, REACH, UL, IEC)?","answer":"The part carries a substance prohibition date of 10/01/2009 for RoHS compliance. The SIRIUS series typically includes CE, UL, and CSA certifications; a declaration of conformity is available from Siemens upon request. Specific documentation should be confirmed at the time of order."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RH2122-1AE00","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RH2122-1AE00 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}