{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RH2122-1AP00-ZW97","brand":"Siemens","brandSlug":"siemens","productSlug":"3RH2122-1AP00-ZW97","canonicalUrl":"https://aoctrl.com/siemens/3RH2122-1AP00-ZW97","factsUrl":"https://aoctrl.com/api/mcp/products/3RH2122-1AP00-ZW97","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS auxiliary contactor, size S00, 3RH2122-1AP00-ZW97, 24 V rated 10 A, screw and snap-on 35 mm DIN rail, 73 x 45 x 57.5 mm.","salesMarkdown":"## What it is and what it does The Siemens 3RH2122-1AP00-ZW97 is a SIRIUS auxiliary contactor in the S00 frame size — the smallest footprint in the SIRIUS contactor family, meant for switching control loads and signaling in a motor starter or contactor assembly. It mounts via screw and snap-on onto 35 mm DIN rail. Rated at 10 A at 24 V, with a 50/60 Hz coil tolerance of 0.8–1.1 x rated voltage at 50 Hz and 0.85–1.1 at 60 Hz. The arcing time sits between 10 and 15 ms. That 10 A at 24 V is the headline figure for control-circuit switching — enough for a bank of pilot lights, relays, or PLC inputs. ## Panel fit and mounting Dimensions: 73 mm deep, 45 mm wide, 57.5 mm tall. Mounting position allows ±180° rotation on a vertical surface and ±22.5° tilt forward/backward. Clearances: 10 mm upwards, 10 mm forwards, 10 mm downwards, 6 mm at the side. Fastening method is screw and snap-on onto 35 mm DIN rail. The snap-on feature means no tools for initial placement; the screw secures it against vibration in a panel. ## Environmental and compliance Operating temperature range -25 to +60 °C; storage -55 to +80 °C. Pollution degree 3 — suitable for industrial environments with conductive pollution or dry non-conductive pollution that becomes conductive due to condensation. Relative humidity minimum 10 %. Substance prohibitance date 10/01/2009 aligns with RoHS compliance.","metaTitle":"Siemens 3RH2122-1AP00-ZW97 SIRIUS Auxiliary Contactor, S00,","metaDescription":"Siemens 3RH2122-1AP00-ZW97 SIRIUS auxiliary contactor, size S00, 24 V rated 10 A. Screw and snap-on 35 mm DIN rail. Current lifecycle. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Width":"45 mm","at AC":"4 ... 15 ms","at DC":"10 000 1/h","Height":"57.5 mm","Upwards":"10 mm","Forwards":"10 mm","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"6 mm","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","During Storage":"-55 ... +80 °C","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"Auxiliary contactor","at 24 V rated value":"10 A","at 60 V rated value":"4.7 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"3 A","at 220 V rated value":"1.2 A","at 230 V rated value":"10 A","at 400 V rated value":"3 A","at 440 V rated value":"0.5 A","at 50 Hz rated value":"230 V","at 500 V rated value":"2 A","at 60 Hz rated value":"230 V","at 600 V rated value":"0.26 A","at 690 V rated value":"1 A","Instantaneous Contact":"2","Relative Humidity Minimum":"10 %","Substance Prohibitance (Date)":"10/01/2009","Product Extension Auxiliary Switch":"Yes","Surge Voltage Resistance Rated Value":"6 kV","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 2x 12","operating frequency at DC-12 maximum":"1 000 1/h","operating frequency at DC-13 maximum":"1 000 1/h","operational current at AC-12 maximum":"10 A","reference code according to IEC 81346-2":"K","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","with low demand rate according to SN 31920":"40 %","apparent holding power of magnet coil at AC":"5.7 VA","apparent pick-up power of magnet coil at AC":"37 VA","with high demand rate according to SN 31920":"73 %","number of NC contacts for auxiliary contacts":"2","number of NO contacts for auxiliary contacts":"2","Type Of Voltage Of The Control Supply Voltage":"AC","contact rating of auxiliary contacts according to UL":"A600 / Q600","Inductive Power Factor With Closing Power Of The Coil":"0.8","Identification Number And Letter For Switching Elements":"22 E","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Inductive Power Factor With The Holding Power Of The Coil":"0.25","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Type Of Electrical Connection For Auxiliary And Control Circuit":"screw-type terminals","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000","Design Of The Fuse Link For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 V":"C characteristic: 6 A; 0.4 kA"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=239171&mlfb=3RH2122-1AP00-ZW97","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RH2122-1AP00-ZW97/alternatives.json"},"ai":{"faq":[{"question":"What is the closest functional second-source to 3RH2122-1AP00-ZW97?","answer":"The 3RH2122-2AV00 is a functional peer in the same SIRIUS S00 family, but it carries different coil voltage and contact ratings — verify the specific coil and contact configuration before substituting."},{"question":"What are the key dimensions of 3RH2122-1AP00-ZW97?","answer":"Depth 73 mm, width 45 mm, height 57.5 mm. Side clearance required is 6 mm."},{"question":"Will 3RH2122-1AP00-ZW97 drop into a panel specified around 3RH2122-2AV00?","answer":"Both are SIRIUS S00 auxiliary contactors with the same mounting footprint — screw and snap-on onto 35 mm DIN rail. The physical swap is direct; check coil voltage and contact ratings on the nameplate before wiring."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RH2122-1AP00-ZW97","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RH2122-1AP00-ZW97 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}