{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RH2122-1BE40-ZW97","brand":"Siemens","brandSlug":"siemens","productSlug":"3RH2122-1BE40-ZW97","canonicalUrl":"https://aoctrl.com/siemens/3RH2122-1BE40-ZW97","factsUrl":"https://aoctrl.com/api/mcp/products/3RH2122-1BE40-ZW97","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RH2122-1BE40-ZW97 contactor relay, Size S00, 2 NO instantaneous contacts, 60 V DC coil, screw and snap-on mounting on 35 mm DIN rail.","salesMarkdown":"## Siemens 3RH2122-1BE40-ZW97 — Contactor Relay, Size S00 The Siemens 3RH2122-1BE40-ZW97 is a Size S00 contactor relay with two instantaneous normally-open contacts, designed for auxiliary switching in control panels. Rated for a 60 V DC coil, the relay draws 4 W during both closing and holding, so the coil circuit sees a steady load — no inrush spike to size a power supply around. Switching capacity varies by voltage: at 24 V DC it handles 10 A, at 60 V DC it handles 4.7 A, and at 110 V DC it handles 3 A. The arcing time of 10 to 15 ms and the maximum operating frequency of 10 000 cycles per hour at AC (1 000 cycles per hour at DC-12 duty) give a clear picture of the relay's intended use — frequent switching in control logic, not heavy motor starting. ## Mounting and Clearance ## Wiring and Environmental Ratings Terminals accept solid or stranded wire: 2× (0.5 to 1.5 mm²), 2× (0.75 to 2.5 mm²), or 2× 4 mm². Storage temperature spans -55 to +80 °C, which exceeds the operating range — that limit governs handling and warehousing, not running conditions. Relative humidity minimum is 10 %, and the part complies with RoHS substance prohibitions effective October 1, 2009. Surge voltage resistance is rated at 6 kV, giving confidence that the relay withstands switching transients common in industrial power distribution without flashover.","metaTitle":"Siemens 3RH2122-1BE40-ZW97 Contactor Relay, Size S00, 2 NO C","metaDescription":"Siemens 3RH2122-1BE40-ZW97 contactor relay, Size S00, 2 instantaneous NO contacts, rated 10 A at 24 V DC. Screw and snap-on mounting on 35 mm DIN rail. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Width":"45 mm","at AC":"10 000 1/h","at DC":"7 ... 13 ms","Height":"58 mm","Upwards":"10 mm","Forwards":"10 mm","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"6 mm","Rated Value":"60 V","Initial Value":"0.8","During Storage":"-55 ... +80 °C","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail","Full-Scale Value":"1.1","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²","Degree Of Pollution":"3","at 24 V rated value":"10 A","at 60 V rated value":"4.7 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"3 A","at 220 V rated value":"1.2 A","at 230 V rated value":"10 A","at 400 V rated value":"3 A","at 440 V rated value":"0.5 A","at 500 V rated value":"2 A","at 600 V rated value":"0.26 A","at 690 V rated value":"1 A","Instantaneous Contact":"2","Relative Humidity Minimum":"10 %","Substance Prohibitance (Date)":"10/01/2009","Product Extension Auxiliary Switch":"Yes","closing power of magnet coil at DC":"4 W","holding power of magnet coil at DC":"4 W","Surge Voltage Resistance Rated Value":"6 kV","operating frequency at DC-12 maximum":"1 000 1/h","operating frequency at DC-13 maximum":"1 000 1/h","operational current at AC-12 maximum":"10 A","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 2x 12","reference code according to IEC 81346-2":"K","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","with low demand rate according to SN 31920":"40 %","with high demand rate according to SN 31920":"73 %","number of NC contacts for auxiliary contacts":"2","number of NO contacts for auxiliary contacts":"2","Type Of Voltage Of The Control Supply Voltage":"DC","contact rating of auxiliary contacts according to UL":"A600 / Q600","Identification Number And Letter For Switching Elements":"22 E","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Type Of Electrical Connection For Auxiliary And Control Circuit":"screw-type terminals","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000","Design Of The Fuse Link For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 V":"C characteristic: 6 A; 0.4 kA"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1684636&mlfb=3RH2122-1BE40-ZW97","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RH2122-1BE40-ZW97/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3RH2122-1BE40-ZW97?","answer":"The part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability confirmation."},{"question":"Will 3RH2122-1BE40-ZW97 drop into a panel specified around 3RH2122-1BW40 without rewiring?","answer":"Both are Size S00 contactor relays with the same mounting footprint on 35 mm DIN rail, so the mechanical fit is identical. The difference is the coil voltage — the -1BW40 variant uses a different coil rating, so verify the control circuit voltage matches before substituting."},{"question":"What are the key switching ratings for 3RH2122-1BE40-ZW97?","answer":"At 24 V DC it switches 10 A; at 60 V DC it switches 4.7 A; at 110 V DC it switches 3 A. The maximum operating frequency is 10 000 cycles per hour at AC and 1 000 cycles per hour at DC-12 duty."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RH2122-1BE40-ZW97","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RH2122-1BE40-ZW97 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}