{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RH2122-2LB40-1LA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RH2122-2LB40-1LA0","canonicalUrl":"https://aoctrl.com/siemens/3RH2122-2LB40-1LA0","factsUrl":"https://aoctrl.com/api/mcp/products/3RH2122-2LB40-1LA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS auxiliary contactor, size S00, 3RH2122-2LB40-1LA0, 24 V DC coil with varistor, 2 NO contacts, screw and snap-on mounting on 35 mm DIN rail.","salesMarkdown":"The 2 NO contacts are rated across a wide voltage range. At 400 V AC the contact carries 10 A, at 230 V AC also 10 A, and at 690 V AC it carries 1 A. For DC switching, at 24 V rated value it handles 10 A, dropping to 0.26 A at 600 V. The DC ratings are lower because DC arcs are harder to extinguish; the 7…20 ms arcing time reflects that. If you're switching a 24 V DC solenoid or contactor coil, the 10 A rating gives generous headroom. ## Panel integration and clearances","metaTitle":"Siemens 3RH2122-2LB40-1LA0 SIRIUS Auxiliary Contactor, 24 VD","metaDescription":"Siemens SIRIUS 3RH2122-2LB40-1LA0 auxiliary contactor, size S00, 24 VDC coil with varistor, 2 NO contacts, 10 A at 400 V AC. Screw/snap-on 35 mm DIN rail. Active production, source","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"116 mm","Width":"45 mm","at AC":"10 000 1/h","at DC":"7 ... 20 ms","Height":"70 mm","Upwards":"10 mm","Forwards":"10 mm","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"6 mm","Rated Value":"24 V","Initial Value":"0.7","During Storage":"-55 ... +80 °C","lifecycle_stage":"current","During Operation":"-40 ... +70 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail","Full-Scale Value":"1.25","Mounting Position":"standing, on horizontal mounting surface","Size Of Contactor":"S00","Solid Or Stranded":"2x (0,5 ... 4 mm²)","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"Auxiliary contactor","at 24 V rated value":"10 A","at 60 V rated value":"4.7 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"3 A","at 220 V rated value":"1.2 A","at 230 V rated value":"10 A","at 400 V rated value":"3 A","at 440 V rated value":"0.5 A","at 500 V rated value":"2 A","at 600 V rated value":"0.26 A","at 690 V rated value":"1 A","Instantaneous Contact":"2","Relative Humidity Minimum":"10 %","Substance Prohibitance (Date)":"10/01/2009","Design Of The Surge Suppressor":"with varistor","Product Extension Auxiliary Switch":"Yes","closing power of magnet coil at DC":"13 W","holding power of magnet coil at DC":"4 W","Surge Voltage Resistance Rated Value":"6 kV","at AWG cables for auxiliary contacts":"2x (20 ... 12)","operating frequency at DC-12 maximum":"1 000 1/h","operating frequency at DC-13 maximum":"1 000 1/h","operational current at AC-12 maximum":"10 A","reference code according to IEC 81346-2":"K","Finely Stranded With Core End Processing":"2x (0.5 ... 2.5 mm²)","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","with low demand rate according to SN 31920":"40 %","Finely Stranded Without Core End Processing":"2x (0.5 ... 2.5 mm²)","with high demand rate according to SN 31920":"73 %","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"2","Type Of Voltage Of The Control Supply Voltage":"DC","contact rating of auxiliary contacts according to UL":"A600 / Q600","Identification Number And Letter For Switching Elements":"21","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Type Of Electrical Connection For Auxiliary And Control Circuit":"spring-loaded terminals","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000","Design Of The Fuse Link For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 V":"C characteristic: 6 A; 0.4 kA"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3bc784ae7394ad450f289cc76bb4a0bb.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=406544&mlfb=3RH2122-2LB40-1LA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RH2122-2LB40-1LA0/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RH2122-2LB40-1LA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RH2122-2LB40-1LA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}