{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RH2131-1FB40-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RH2131-1FB40-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RH2131-1FB40-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RH2131-1FB40-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3RH2131-1FB40-ZX95 auxiliary contactor, size S00, 24 VDC coil, 3 NO instantaneous contacts, diode surge suppressor, screw and snap-on mounting on 35 mm DIN rail, 73 mm depth, 45 mm width, 58 mm height.","salesMarkdown":"The 3RH2131-1FB40-ZX95: Pollution degree 3 rated, so it handles conductive dust environments typical in industrial panels. ## DC switching capacity across voltages The built-in diode surge suppressor (across the coil) handles the DC coil's 4 W closing and holding power, protecting nearby PLC outputs from voltage spikes. Relative humidity minimum 10 %. RoHS compliance effective 2009-10-01 per substance prohibitance date. Surge voltage resistance rated at 6 kV — suitable for IEC 60947-1 coordination.","metaTitle":"Siemens 3RH2131-1FB40-ZX95 Auxiliary Contactor, S00, 24 VDC","metaDescription":"Siemens 3RH2131-1FB40-ZX95 auxiliary contactor, size S00, 24 VDC coil, 3 NO contacts, 73 mm depth, 45 mm width. Active production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Width":"45 mm","at AC":"10 000 1/h","at DC":"38 ... 65 ms","title":"3RH2131-1FB40-ZX95","Height":"58 mm","Upwards":"10 mm","Forwards":"10 mm","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"6 mm","Rated Value":"24 V","description":"Contactor relay, 3 NO + 1 NC, 24 V DC, with integrated diode, Size S00, screw terminal Reusable packaging = 72 units","Initial Value":"0.8","During Storage":"-55 ... +80 °C","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail","Full-Scale Value":"1.1","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²","Degree Of Pollution":"3","at 24 V rated value":"10 A","at 60 V rated value":"4.7 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"3 A","at 220 V rated value":"1.2 A","at 230 V rated value":"10 A","at 400 V rated value":"3 A","at 440 V rated value":"0.5 A","at 500 V rated value":"2 A","at 600 V rated value":"0.26 A","at 690 V rated value":"1 A","Instantaneous Contact":"3","Relative Humidity Minimum":"10 %","Substance Prohibitance (Date)":"10/01/2009","Design Of The Surge Suppressor":"diode","Product Extension Auxiliary Switch":"Yes","closing power of magnet coil at DC":"4 W","holding power of magnet coil at DC":"4 W","Surge Voltage Resistance Rated Value":"6 kV","operating frequency at DC-12 maximum":"1 000 1/h","operating frequency at DC-13 maximum":"1 000 1/h","operational current at AC-12 maximum":"10 A","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 2x 12","reference code according to IEC 81346-2":"K","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","with low demand rate according to SN 31920":"40 %","with high demand rate according to SN 31920":"73 %","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"3","Type Of Voltage Of The Control Supply Voltage":"DC","contact rating of auxiliary contacts according to UL":"A600 / Q600","Identification Number And Letter For Switching Elements":"31 E","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Type Of Electrical Connection For Auxiliary And Control Circuit":"screw-type terminals","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000","Design Of The Fuse Link For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 V":"C characteristic: 6 A; 0.4 kA"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d896dcd8d8661bd1e2a6fb70bd77f600.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1420897&mlfb=3RH2131-1FB40-ZX95"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RH2131-1FB40-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RH2131-1FB40-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}