{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RH2131-2AP00-ZW97","brand":"Siemens","brandSlug":"siemens","productSlug":"3RH2131-2AP00-ZW97","canonicalUrl":"https://aoctrl.com/siemens/3RH2131-2AP00-ZW97","factsUrl":"https://aoctrl.com/api/mcp/products/3RH2131-2AP00-ZW97","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS auxiliary contactor, size S00, 3 NO + 1 NC instantaneous contacts, screw and snap-on 35 mm DIN rail mounting, 45 mm wide.","salesMarkdown":"## SIRIUS auxiliary contactor, size S00 — 3NO+1NC, screw terminals The 3RH2131-2AP00-ZW97 is a Siemens SIRIUS auxiliary contactor in frame size S00, delivering 3 normally-open and 1 normally-closed instantaneous contacts. Rated operational current varies by voltage and duty: 10 A at 24 V and 230 V, 4.7 A at 60 V, 3 A at 110 V and 400 V, 1.2 A at 220 V, 0.5 A at 440 V, 2 A at 500 V, 0.26 A at 600 V, and 1 A at 690 V. These are the contact ratings — match your control voltage to the appropriate column for thermal capacity. Snap-on mounting onto 35 mm standard mounting rail; screw terminals accept 2x (0.5 to 4 mm²) solid or stranded wire. The S00 frame size keeps the footprint compact — 45 mm wide, 70 mm high, 73 mm deep — so it fits tight DIN-rail layouts alongside contactors and overload relays. Pollution degree 3 rated, so it handles conductive dust environments common in industrial panels. Relative humidity minimum 10 %. The part is RoHS-compliant per the 10/01/2009 substance prohibition date. For a BOM line or urgent replacement, this order code sources to a firm RFQ. No last-time-buy window to watch; the part is active and factory-supported.","metaTitle":"Siemens 3RH2131-2AP00-ZW97 SIRIUS Auxiliary Contactor, S00,","metaDescription":"Siemens 3RH2131-2AP00-ZW97 SIRIUS auxiliary contactor, size S00, 3 NO + 1 NC contacts, 45 mm wide, screw and snap-on DIN rail mount, current production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Width":"45 mm","at AC":"4 ... 15 ms","at DC":"10 000 1/h","title":"3RH2131-2AP00-ZW97","Height":"70 mm","Upwards":"10 mm","Forwards":"10 mm","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"6 mm","description":"Contactor relay, 3 NO + 1 NC, 230 V AC, 50 / 60 Hz, Size S00, Spring-type terminal Multi-unit packaging = 32 units","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","During Storage":"-55 ... +80 °C","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Solid Or Stranded":"2x (0,5 ... 4 mm²)","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"Auxiliary contactor","at 24 V rated value":"10 A","at 60 V rated value":"4.7 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"3 A","at 220 V rated value":"1.2 A","at 230 V rated value":"10 A","at 400 V rated value":"3 A","at 440 V rated value":"0.5 A","at 50 Hz rated value":"230 V","at 500 V rated value":"2 A","at 60 Hz rated value":"230 V","at 600 V rated value":"0.26 A","at 690 V rated value":"1 A","Instantaneous Contact":"3","Relative Humidity Minimum":"10 %","Substance Prohibitance (Date)":"10/01/2009","Product Extension Auxiliary Switch":"Yes","Surge Voltage Resistance Rated Value":"6 kV","at AWG cables for auxiliary contacts":"2x (20 ... 12)","operating frequency at DC-12 maximum":"1 000 1/h","operating frequency at DC-13 maximum":"1 000 1/h","operational current at AC-12 maximum":"10 A","reference code according to IEC 81346-2":"K","Finely Stranded With Core End Processing":"2x (0.5 ... 2.5 mm²)","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","with low demand rate according to SN 31920":"40 %","Finely Stranded Without Core End Processing":"2x (0.5 ... 2.5 mm²)","apparent holding power of magnet coil at AC":"5.7 VA","apparent pick-up power of magnet coil at AC":"37 VA","with high demand rate according to SN 31920":"73 %","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"3","Type Of Voltage Of The Control Supply Voltage":"AC","contact rating of auxiliary contacts according to UL":"A600 / Q600","Inductive Power Factor With Closing Power Of The Coil":"0.8","Identification Number And Letter For Switching Elements":"31 E","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Inductive Power Factor With The Holding Power Of The Coil":"0.25","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Type Of Electrical Connection For Auxiliary And Control Circuit":"spring-loaded terminals","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000","Design Of The Fuse Link For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 V":"C characteristic: 6 A; 0.4 kA"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c8e0f368e0fd34c7206ab83036591629.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=513909&mlfb=3RH2131-2AP00-ZW97"},"ai":{"faq":[{"question":"What are the key dimensions for panel layout?","answer":"Width 45 mm, height 70 mm, depth 73 mm. Requires 10 mm clearance upwards and forwards, 10 mm downwards, and 6 mm at the side."},{"question":"What contact configuration does this auxiliary contactor have?","answer":"3 normally-open and 1 normally-closed instantaneous contacts. Arcing time is 10 to 15 ms at AC, with a maximum switching frequency of 10,000 operations per hour at DC."},{"question":"What compliance documentation is available?","answer":"RoHS compliant per the 10/01/2009 substance prohibition date. The SIRIUS series carries IEC and UL certifications typical for industrial control gear."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RH2131-2AP00-ZW97","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RH2131-2AP00-ZW97 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}