{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RH2131-2VB40","brand":"Siemens","brandSlug":"siemens","productSlug":"3RH2131-2VB40","canonicalUrl":"https://aoctrl.com/siemens/3RH2131-2VB40","factsUrl":"https://aoctrl.com/api/mcp/products/3RH2131-2VB40","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RH2131-2VB40 coupling relay, size S00, 24 VDC coil with integrated diode suppression, 3 NO + 1 NC contacts, 10 A rated at 230 V, screw and snap-on 35 mm DIN rail mounting.","salesMarkdown":"## Panel fit and mounting constraints The 3RH2131-2VB40 measures 45 mm wide by 70 mm tall by 73 mm deep — a size S00 footprint that fits standard 35 mm DIN rail enclosures without crowding adjacent devices. Snap-on mounting to the DIN rail is the primary method, with screw fixing also supported. ## Coil drive and contact ratings The 24 VDC coil draws 1.6 W closing power and includes an integrated diode surge suppressor — no external flyback diode needed when the PLC output drives it. ## Lifecycle and compliance status RoHS compliance date is 10/01/2009.","metaTitle":"Siemens 3RH2131-2VB40 SIRIUS Coupling Relay, 24 VDC, 10 A","metaDescription":"Siemens 3RH2131-2VB40 SIRIUS coupling relay, size S00, 24 VDC coil, 10 A rated current at 230 V. Screw and snap-on mounting to 35 mm DIN rail.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Width":"45 mm","at AC":"10 000 1/h","at DC":"20 ... 80 ms","title":"3RH2131-2VB40","Height":"70 mm","Upwards":"10 mm","Forwards":"10 mm","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"6 mm","Rated Value":"24 V","description":"Coupling contactor relay, 3 NO + 1 NC, 24 V DC, 0.85... 1.85* US, with integrated diode, Size S00, Spring-type terminal","Initial Value":"0.85","During Storage":"-55 ... +80 °C","lifecycle_stage":"current","During Operation":"-25 ... +50 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail","Full-Scale Value":"1.85","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Solid Or Stranded":"2x (0,5 ... 4 mm²)","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"Coupling relay for switching auxiliary circuits","at 24 V rated value":"10 A","at 60 V rated value":"4.7 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"3 A","at 220 V rated value":"1.2 A","at 230 V rated value":"10 A","at 400 V rated value":"3 A","at 440 V rated value":"0.5 A","at 500 V rated value":"2 A","at 600 V rated value":"0.26 A","at 690 V rated value":"1 A","Instantaneous Contact":"3","Relative Humidity Minimum":"10 %","Substance Prohibitance (Date)":"10/01/2009","Design Of The Surge Suppressor":"diode","Product Extension Auxiliary Switch":"No","closing power of magnet coil at DC":"1.6 W","holding power of magnet coil at DC":"1.6 W","Surge Voltage Resistance Rated Value":"6 kV","at AWG cables for auxiliary contacts":"2x (20 ... 12)","operating frequency at DC-12 maximum":"1 000 1/h","operating frequency at DC-13 maximum":"1 000 1/h","operational current at AC-12 maximum":"10 A","reference code according to IEC 81346-2":"K","Finely Stranded With Core End Processing":"2x (0.5 ... 2.5 mm²)","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","with low demand rate according to SN 31920":"40 %","Finely Stranded Without Core End Processing":"2x (0.5 ... 2.5 mm²)","with high demand rate according to SN 31920":"73 %","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"3","Type Of Voltage Of The Control Supply Voltage":"DC","contact rating of auxiliary contacts according to UL":"A600 / Q600","Identification Number And Letter For Switching Elements":"31 E","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Type Of Electrical Connection For Auxiliary And Control Circuit":"spring-loaded terminals","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Design Of The Fuse Link For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 V":"C characteristic: 6 A; 0.4 kA"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$25.40","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/289c76691965cbc4df1b6923c82f4560.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=171026&mlfb=3RH2131-2VB40"},"ai":{"faq":[{"question":"What compliance documentation does Siemens provide for 3RH2131-2VB40?","answer":"RoHS compliance is confirmed with a substance prohibition date of 10/01/2009."},{"question":"What are the clearance distances needed around this relay?","answer":"The side clearance is driven by the 10–15 ms DC arcing time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RH2131-2VB40","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RH2131-2VB40 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}