{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RH2131-4AG60","brand":"Siemens","brandSlug":"siemens","productSlug":"3RH2131-4AG60","canonicalUrl":"https://aoctrl.com/siemens/3RH2131-4AG60","factsUrl":"https://aoctrl.com/api/mcp/products/3RH2131-4AG60","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS auxiliary contactor, Size S00, 3RH2131-4AG60, screw and snap-on mounting on 35 mm standard mounting rail, 10 A rated at 24 V and 230 V.","salesMarkdown":"It carries a 10 A rated value at both 24 V and 230 V, so it handles the typical control-voltage range across European and North American panels without derating at the higher voltage. Dimensions are 45 mm wide, 57.5 mm high, and 73 mm deep — a compact footprint that leaves room alongside contactors or terminals on the same DIN rail. Clearance requirements: 10 mm upwards, 10 mm forwards, 10 mm downwards, and 6 mm at the side — plan your gland plate and wireway accordingly to avoid heat buildup. Operating temperature range is -25 to +60 °C; storage range -55 to +80 °C, so it survives transport and storage in unheated warehouses.","metaTitle":"Siemens 3RH2131-4AG60 SIRIUS Auxiliary Contactor, Size S00,","metaDescription":"Siemens SIRIUS 3RH2131-4AG60 auxiliary contactor, Size S00, 10 A rated at 24 V and 230 V. Screw/snap-on 35 mm DIN rail. Current lifecycle. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Width":"45 mm","at AC":"4 ... 15 ms","at DC":"10 000 1/h","Height":"57.5 mm","Upwards":"10 mm","Forwards":"10 mm","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"6 mm","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","During Storage":"-55 ... +80 °C","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"Auxiliary contactor","at 24 V rated value":"10 A","at 60 V rated value":"4.7 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"3 A","at 220 V rated value":"1.2 A","at 230 V rated value":"10 A","at 400 V rated value":"3 A","at 440 V rated value":"0.5 A","at 50 Hz rated value":"100 V","at 500 V rated value":"2 A","at 60 Hz rated value":"100 ... 110 V","at 600 V rated value":"0.26 A","at 690 V rated value":"1 A","Instantaneous Contact":"3","Relative Humidity Minimum":"10 %","Substance Prohibitance (Date)":"10/01/2009","Product Extension Auxiliary Switch":"Yes","Surge Voltage Resistance Rated Value":"6 kV","operating frequency at DC-12 maximum":"1 000 1/h","operating frequency at DC-13 maximum":"1 000 1/h","operational current at AC-12 maximum":"10 A","reference code according to IEC 81346-2":"K","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","with low demand rate according to SN 31920":"40 %","apparent holding power of magnet coil at AC":"5.7 VA","apparent pick-up power of magnet coil at AC":"37 VA","with high demand rate according to SN 31920":"73 %","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"3","Type Of Voltage Of The Control Supply Voltage":"AC","contact rating of auxiliary contacts according to UL":"A600 / Q600","Inductive Power Factor With Closing Power Of The Coil":"0.8","Identification Number And Letter For Switching Elements":"31 E","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Inductive Power Factor With The Holding Power Of The Coil":"0.25","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","Type Of Electrical Connection For Auxiliary And Control Circuit":"ring terminal lug connection","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000","Design Of The Fuse Link For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 V":"C characteristic: 6 A; 0.4 kA"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=457739&mlfb=3RH2131-4AG60","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RH2131-4AG60/alternatives.json"},"ai":{"faq":[{"question":"Will 3RH2131-4AG60 drop into a panel that was specified around 3RH2131-2AK60 without rewiring?","answer":"Both are Size S00 auxiliary contactors with the same DIN-rail footprint and similar clearance requirements, so mechanical fit is the same — but always compare the coil voltage and contact arrangement on the nameplate before assuming electrical interchangeability."},{"question":"What compliance documentation does Siemens provide for 3RH2131-4AG60?","answer":"The part carries a substance prohibitance date of 10/01/2009, indicating RoHS compliance from that date forward; typical Siemens SIRIUS documentation includes a CE declaration and manufacturer's declaration for the applicable EU directives."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RH2131-4AG60","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RH2131-4AG60 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}