{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RH2344-1DG40","brand":"Siemens","brandSlug":"siemens","productSlug":"3RH2344-1DG40","canonicalUrl":"https://aoctrl.com/siemens/3RH2344-1DG40","factsUrl":"https://aoctrl.com/api/mcp/products/3RH2344-1DG40","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS auxiliary contactor, size S00, 4 NO instantaneous contacts, screw and snap-on mounting for 35 mm DIN rail, 45 mm width, 117 mm depth, 57.5 mm height.","salesMarkdown":"It mounts via screw and snap-on onto a 35 mm standard mounting rail, with a width of 45 mm, depth of 117 mm, and height of 57.5 mm. ## Switching capacity and contact ratings The 4 NO contacts are rated for DC switching at 125 V with an initial value of 0.8 and full-scale value of 1.1. AC switching capacity reaches 10,000 operations per hour, with an arcing time of 10 to 15 ms and DC switching duration of 7 to 13 ms. Rated currents vary by voltage: 10 A at 24 V, 4.7 A at 60 V, 3 A at 110 V, 1.2 A at 220 V, 6 A at 230 V, 3 A at 400 V, 0.5 A at 440 V, 2 A at 500 V, 0.26 A at 600 V, and 1 A at 690 V. Relative humidity minimum is 10%. The contactor includes a built-in varistor surge suppressor. It complies with RoHS substance prohibitions effective July 1, 2006.","metaTitle":"Siemens 3RH2344-1DG40 SIRIUS Auxiliary Contactor, 4 NO, 45 m","metaDescription":"Siemens 3RH2344-1DG40 SIRIUS auxiliary contactor, size S00, 4 NO contacts, 45 mm width, screw and snap-on DIN rail mount. Currently in production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"117 mm","Width":"45 mm","at AC":"10 000 1/h","at DC":"7 ... 13 ms","Height":"57.5 mm","Upwards":"10 mm","Forwards":"10 mm","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"6 mm","Rated Value":"125 V","Initial Value":"0.8","During Storage":"-55 ... +80 °C","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail","Full-Scale Value":"1.1","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"Auxiliary contactor","at 24 V rated value":"10 A","at 60 V rated value":"4.7 A","Of Contactor Typical":"10 000 000","at 110 V rated value":"3 A","at 220 V rated value":"1.2 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 440 V rated value":"0.5 A","at 500 V rated value":"2 A","at 600 V rated value":"0.26 A","at 690 V rated value":"1 A","Instantaneous Contact":"4","Relative Humidity Minimum":"10 %","Substance Prohibitance (Date)":"07/01/2006","Design Of The Surge Suppressor":"with varistor","Product Extension Auxiliary Switch":"No","closing power of magnet coil at DC":"4 W","holding power of magnet coil at DC":"4 W","Surge Voltage Resistance Rated Value":"6 kV","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 2x 12","operating frequency at DC-12 maximum":"1 000 1/h","operating frequency at DC-13 maximum":"1 000 1/h","operational current at AC-12 maximum":"10 A","reference code according to IEC 81346-2":"K","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","with low demand rate according to SN 31920":"40 %","with high demand rate according to SN 31920":"73 %","number of NC contacts for auxiliary contacts":"4","number of NO contacts for auxiliary contacts":"4","Type Of Voltage Of The Control Supply Voltage":"DC","contact rating of auxiliary contacts according to UL":"A600 / Q600","Identification Number And Letter For Switching Elements":"44 E","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Type Of Electrical Connection For Auxiliary And Control Circuit":"screw-type terminals","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Design Of The Fuse Link For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 V":"C characteristic: 6 A; 0.4 kA"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/68b5ed1df2b6e5843e30fb221bff344a.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=491574&mlfb=3RH2344-1DG40","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RH2344-1DG40/alternatives.json"},"ai":{"faq":[{"question":"What are the key dimensions of 3RH2344-1DG40?","answer":"Width is 45 mm, depth is 117 mm, and height is 57.5 mm."},{"question":"What is the contact configuration on 3RH2344-1DG40?","answer":"It has 4 normally-open instantaneous contacts."},{"question":"How do I get current pricing and availability for 3RH2344-1DG40?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution, with availability and current pricing confirmed at quote time."},{"question":"What compliance documentation does Siemens provide for 3RH2344-1DG40?","answer":"The contactor complies with RoHS substance prohibitions effective July 1, 2006. It carries a pollution degree 3 rating."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RH2344-1DG40","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RH2344-1DG40 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}