{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RH2431-1BF40","brand":"Siemens","brandSlug":"siemens","productSlug":"3RH2431-1BF40","canonicalUrl":"https://aoctrl.com/siemens/3RH2431-1BF40","factsUrl":"https://aoctrl.com/api/mcp/products/3RH2431-1BF40","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RH2431-1BF40, Size S00 auxiliary contactor, 3 NO instantaneous contacts, 110 V AC coil, screw and snap-on 35 mm DIN rail mounting.","salesMarkdown":"The three NO contacts are rated for switching at various voltages: 10 A at 24 V, 4.7 A at 60 V, 3 A at 110 V, 1.2 A at 220 V, 10 A at 230 V, 3 A at 400 V, 0.5 A at 440 V, 2 A at 500 V, 0.26 A at 600 V, and 1 A at 690 V. These are the maximum continuous switching currents per contact at the given AC voltage levels — so if you're switching a 400 V pilot light, you're limited to 3 A per contact. For a 24 V DC solenoid, the 10 A rating gives you headroom for inrush. The contacts are rated for 10,000 operations per hour (AC) with an arcing time of 10 to 15 ms, and a typical mechanical life of 5,000,000 operations for the contactor assembly. The coil pickup is rated at 0.8 x rated voltage (88 V for this 110 V unit), and dropout is at 1.1 x rated voltage (121 V), so it stays pulled in across a reasonable brownout range. The contactor measures 57.5 mm high, 90 mm wide, and 73 mm deep — compact enough for a crowded DIN rail. Operating temperature range is -25 to +60 °C, storage from -55 to +80 °C, with pollution degree 3 (industrial environment with conductive or dry non-conductive pollution). Relative humidity minimum is 10%. Wiring accepts 2 x 0.5 to 1.5 mm², 2 x 0.75 to 2.5 mm², or 2 x 4 mm² solid or stranded conductors — standard for control circuit terminations. The product carries a RoHS substance prohibition date of 10/01/2009, confirming compliance with the 2009 RoHS directive.","metaTitle":"Siemens SIRIUS 3RH2431-1BF40 Auxiliary Contactor, 110 V Coil","metaDescription":"Siemens SIRIUS 3RH2431-1BF40 auxiliary contactor. Size S00, 3 NO instantaneous contacts, 110 V AC coil. Screw and snap-on 35 mm DIN rail mounting. Current production. Sourced to or","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Width":"90 mm","at AC":"10 000 1/h","at DC":"7 ... 13 ms","title":"3RH2431-1BF40","Height":"57.5 mm","Upwards":"10 mm","Forwards":"10 mm","Downwards":"10 mm","Arcing Time":"10 ... 15 ms","At The Side":"6 mm","Rated Value":"110 V","description":"Contactor relay, latched, 3 NO + 1 NC, 110 V DC, Size S00, screw terminal","Initial Value":"0.8","During Storage":"-55 ... +80 °C","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail","Full-Scale Value":"1.1","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","Size Of Contactor":"S00","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"Auxiliary contactor","at 24 V rated value":"10 A","at 60 V rated value":"4.7 A","Of Contactor Typical":"5 000 000","at 110 V rated value":"3 A","at 220 V rated value":"1.2 A","at 230 V rated value":"10 A","at 400 V rated value":"3 A","at 440 V rated value":"0.5 A","at 500 V rated value":"2 A","at 600 V rated value":"0.26 A","at 690 V rated value":"1 A","Instantaneous Contact":"3","Relative Humidity Minimum":"10 %","Substance Prohibitance (Date)":"10/01/2009","Product Extension Auxiliary Switch":"Yes","closing power of magnet coil at DC":"4 W","holding power of magnet coil at DC":"4 W","Surge Voltage Resistance Rated Value":"6 kV","operating frequency at DC-12 maximum":"1 000 1/h","operating frequency at DC-13 maximum":"1 000 1/h","operational current at AC-12 maximum":"10 A","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 2x 12","reference code according to IEC 81346-2":"K","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","with low demand rate according to SN 31920":"40 %","with high demand rate according to SN 31920":"73 %","number of NC contacts for auxiliary contacts":"1","number of NO contacts for auxiliary contacts":"3","Type Of Voltage Of The Control Supply Voltage":"DC","contact rating of auxiliary contacts according to UL":"A600 / Q600","Identification Number And Letter For Switching Elements":"31 E","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Of The Contactor With Added Auxiliary Switch Block Typical":"5 000 000","Type Of Electrical Connection For Auxiliary And Control Circuit":"screw-type terminals","insulation voltage with degree of pollution 3 at AC rated value":"690 V","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000","Design Of The Fuse Link For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 V":"C characteristic: 6 A; 0.4 kA"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a900253183ad16b48042656c013a96f4.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=122742&mlfb=3RH2431-1BF40"},"ai":{"faq":[{"question":"What are the key switching ratings for this contactor?","answer":"The three NO contacts are rated for 10 A at 24 V AC, 3 A at 110 V, 1.2 A at 220 V, 10 A at 230 V, 3 A at 400 V, and 1 A at 690 V, among other intermediate voltage ratings. The coil is 110 V AC, drawing 4 W for both closing and holding."},{"question":"What are the mounting dimensions and clearances?","answer":"The contactor is 57.5 mm high, 90 mm wide, and 73 mm deep. It requires 10 mm clearance upwards, forwards, and downwards, and 6 mm at the sides. It mounts on 35 mm DIN rail via screw or snap-on."},{"question":"What compliance documentation is available?","answer":"The product has a RoHS substance prohibition date of 10/01/2009, indicating compliance with the 2009 RoHS directive. It is rated for pollution degree 3 per IEC standards."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RH2431-1BF40","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RH2431-1BF40 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}