{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RH2911-1GA04-ZW96","brand":"Siemens","brandSlug":"siemens","productSlug":"3RH2911-1GA04-ZW96","canonicalUrl":"https://aoctrl.com/siemens/3RH2911-1GA04-ZW96","factsUrl":"https://aoctrl.com/api/mcp/products/3RH2911-1GA04-ZW96","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RH2911-1GA04-ZW96 auxiliary switch block, 4 NC, front-mount, physically coded, screw-type terminals, rated 10 A maximum, IP20, snap-on mounting.","salesMarkdown":"## What the 10 A rating and AC-15 current bands mean for your control circuit The 3RH2911-1GA04-ZW96 is a front-mounted auxiliary switch block carrying 4 normally-closed contacts (51/52, 61/62, 71/72, 81/82) physically coded to mate only with Siemens SIRIUS contactor relays 3RH2140 and 3RH2440 per EN 50011. The 10 A maximum rating is the thermal current ceiling; the real selection driver is the AC-15 utilization category current at your control voltage — 6 A at 24 V, 6 A at 125 V, 6 A at 230 V, 3 A at 400 V, and 1 A at 690 V. Match the column to your solenoid or contactor coil load: if you're switching 230 V AC pilot duty, the 6 A rating gives you headroom for inrush without derating. ## Contact reliability for low-level signals and mechanical endurance The auxiliary contacts are rated for 1 faulty switching per 100 million operations at 17 V, 1 mA — that is the dry-circuit reliability floor for PLC-level signals and low-energy pilot circuits. If your application involves switching below 17 V or below 1 mA, you need to check the minimum load specification separately. Mechanical service life is 10 million switching cycles typical, which is the practical limit for the spring mechanism before replacement in high-cycle applications like packaging or conveyor interlocks. ## Wiring, mounting, and panel fit Snap-on mounting to a DIN rail — no tools needed for installation or removal. Terminals are screw-type accepting 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²) solid/stranded, or 2x (20 to 16 AWG) or 2x (18 to 14 AWG). The physical coding prevents accidental mating with the wrong contactor relay — the block only fits 3RH2140 and 3RH2440 frames. Front IP20 means it is suitable for protected panel interiors only; no washdown or outdoor exposure. ## Insulation coordination and surge withstand Rated insulation voltage is 690 V AC at pollution degree 3 with a surge voltage resistance of 6 kV. This means the block can be installed in 400 V and 690 V panels without additional creepage or clearance derating, even in a pollution degree 3 environment (conductive dust or humidity). Operating temperature range is -25 to +60 °C; storage range is -55 to +80 °C.","metaTitle":"Siemens 3RH2911-1GA04-ZW96 SIRIUS Auxiliary Switch, 4 NC","metaDescription":"Siemens 3RH2911-1GA04-ZW96 SIRIUS auxiliary switch block, 4 NC, front-mount, screw terminals, rated 10 A max, IP20, active production, available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Note":"with 3RH2","Depth":"43.7 mm","Width":"36 mm","title":"3RH2911-1GA04-ZW96","Height":"37.5 mm","Maximum":"10 A","at 24 V":"6 A","at 60 V":"2 A","at 110 V":"1 A","at 125 V":"6 A","at 220 V":"0.3 A","at 230 V":"6 A","at 250 V":"6 A","at 400 V":"3 A","description":"auxiliary switch, on the front, 4 NC, 51/52, 61/62, 71/72, 81/82, current path: 1 NC, 1 NC, 1 NC, 1 NC, screw terminal, physically coded, only with contactor relays 3RH2140 and 3RH2440 combinable (according to EN 50011), multi-unit packaging, pack = 240 units","During Storage":"-55 ... +80 °C","Leading Contact":"0","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"snap-on mounting","Lagging Switching":"0","Product Brand Name":"SIRIUS","Suitability For Use":"Contactor relay","at 24 V rated value":"10 A","at 60 V rated value":"4.7 A","at 110 V rated value":"3 A","at 220 V rated value":"1.2 A","at 440 V rated value":"0.5 A","at 600 V rated value":"0.26 A","Instantaneous Contact":"0","With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","at AC-15 at 690 V rated value":"1 A","protection class IP on the front":"IP20","Surge Voltage Resistance Rated Value":"6 kV","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Mechanical Service Life (Switching Cycles) Typical":"10 000 000","Type Of Electrical Connection For Auxiliary And Control Circuit":"screw-type terminals","insulation voltage with degree of pollution 3 at AC rated value":"690 V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ef513ef05fa7d4731ccf7bb396a9c38c.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=774107&mlfb=3RH2911-1GA04-ZW96"},"ai":{"faq":[{"question":"What contactor relays does the 3RH2911-1GA04-ZW96 physically fit?","answer":"It is physically coded to mount only on Siemens SIRIUS contactor relays 3RH2140 and 3RH2440 per EN 50011. It will not fit other frame sizes without the physical coding matching."},{"question":"What is the AC-15 rated current at 230 V for this auxiliary switch?","answer":"At 230 V AC-15, the rated operational current is 6 A. The same 6 A rating applies at 24 V, 125 V, and 250 V; it drops to 3 A at 400 V and 1 A at 690 V."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RH2911-1GA04-ZW96","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RH2911-1GA04-ZW96 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}