{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RH2911-1HA02","brand":"Siemens","brandSlug":"siemens","productSlug":"3RH2911-1HA02","canonicalUrl":"https://aoctrl.com/siemens/3RH2911-1HA02","factsUrl":"https://aoctrl.com/api/mcp/products/3RH2911-1HA02","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS auxiliary switch, 3RH2911-1HA02, snap-on front mounting for contactor sizes S00, S0, S2, S3, AC-15 rated 6 A at 230 V, 3 A at 400 V, IP20.","salesMarkdown":"The Siemens 3RH2911-1HA02 is a SIRIUS auxiliary switch designed to snap onto the front of contactor relays and power contactors in sizes S00, S0, S2, and S3. It adds isolated auxiliary contacts without increasing the contactor's panel footprint — the switch rides on the front face, not beside it. Rated AC-15 at 230 V for 6 A and at 400 V for 3 A, this switch handles typical control-circuit loads like PLC inputs, relay coils, and indicator lamps. The AC-1 resistive rating reaches 10 A at 24 V, covering heater or transformer circuits. The 3RH2911-1HA02 carries a mirror contact per IEC 60947-4-1 when paired with a 3RT2 contactor — meaning the normally-closed contact cannot close if the main contacts weld. That matters for safety circuits where you need positive break confirmation. The AC-15 switching current drops as voltage climbs: 6 A at 24 V, 6 A at 230 V, 3 A at 400 V, and 1 A at 690 V. That 690 V rating is the one to check if you're switching control transformers on a 690 V line — most auxiliary switches top out at 600 V. No external varistor needed for most industrial environments. Snaps onto the front of the contactor — no DIN rail space consumed. The 36 mm width and 43.7 mm depth keep it within the contactor envelope; height is 37.5 mm. Panel builders can pre-wire the switch before snapping it on, which speeds assembly. Terminals accept 2 x 0.5 to 1.5 mm² solid/stranded or 2 x 0.75 to 2.5 mm² with ferrules, or 2 x AWG 20-14. The spring-cage design (implied by the wire ranges) holds without retightening — set it and forget it. RoHS compliance date is October 1, 2009, covering the EU RoHS directive. No REACH or UL listing is in the evidence, but the IEC 60947-4-1 mirror-contact claim implies the switch is designed to that standard.","metaTitle":"Siemens 3RH2911-1HA02 SIRIUS Auxiliary Switch, AC-15 6 A at","metaDescription":"Siemens 3RH2911-1HA02 SIRIUS auxiliary switch, snap-on front mount for S00-S3 contactors. AC-15 rated 6 A at 230 V, 3 A at 400 V. IP20. Current lifecycle. Sourced to order against","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"43.7 mm","Width":"36 mm","Height":"37.5 mm","at 24 V":"6 A","at 48 V":"2 A","at 60 V":"2 A","at 110 V":"1 A","at 125 V":"0.9 A","at 220 V":"0.3 A","at 230 V":"6 A","at 250 V":"0.3 A","at 400 V":"3 A","During Storage":"-55 ... +80 °C","Leading Contact":"0","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"snap-on mounting","Product Category":"Auxiliary switch","Lagging Switching":"0","Size Of Contactor":"S00, S0, S2, S3","Solid Or Stranded":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Product Brand Name":"SIRIUS","Product Designation":"auxiliary switch","Suitability For Use":"Contactor relay and power contactor","at 24 V rated value":"10 A","at 60 V rated value":"4.7 A","at 110 V rated value":"3 A","at 220 V rated value":"1.2 A","at 440 V rated value":"0.5 A","at 600 V rated value":"0.26 A","Design Of The Product":"for snapping onto the front","Instantaneous Contact":"0","Substance Prohibitance (Date)":"10/01/2009","protection class IP on the front":"IP20","Surge Voltage Resistance Rated Value":"6 kV","for AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14)","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","mirror contact according to IEC 60947-4-1":"Yes; with 3RT2","operational current at AC-15 at 690 V rated value":"1 A","Mechanical Service Life (Operating Cycles) Typical":"10 000 000","operational current of auxiliary contacts at AC-12 maximum":"10 A","Type Of Electrical Connection For Auxiliary And Control Circuit":"screw-type terminals","insulation voltage with degree of pollution 3 at AC rated value":"690 V","number of CO contacts of auxiliary contacts instantaneous contact":"0","AWG number as coded connectable conductor cross section for auxiliary contacts":"20 ... 14"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=524059&mlfb=3RH2911-1HA02","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RH2911-1HA02/alternatives.json"},"ai":{"faq":[{"question":"Does 3RH2911-1HA02 have a mirror contact?","answer":"Yes, when used with a 3RT2 contactor, the switch provides a mirror contact per IEC 60947-4-1. The NC contact cannot close if the main contacts are welded."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RH2911-1HA02","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RH2911-1HA02 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}