{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RH2911-2NF22","brand":"Siemens","brandSlug":"siemens","productSlug":"3RH2911-2NF22","canonicalUrl":"https://aoctrl.com/siemens/3RH2911-2NF22","factsUrl":"https://aoctrl.com/api/mcp/products/3RH2911-2NF22","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS auxiliary switch block, 3RH2911-2NF22, 2 NO + 2 NC, solid-state compatible, spring-loaded terminals, for 3RT2 contactors and 3RH2 contactor relays.","salesMarkdown":"The Siemens 3RH2911-2NF22 is a front-mounted auxiliary switch block for the SIRIUS 3RT2 contactor family and 3RH2 contactor relays. It provides two normally-open and two normally-closed contacts, with two of the NC contacts designated as solid-state compatible — meaning they are rated for reliable switching at low-level signals (5 V, 1 mA) where standard contacts might oxidize and fail to conduct. The note on the order code — \"with 3RT2.2/3/4\" — confirms it mounts directly onto the front of 3RT2 contactors in frame sizes S2, S3, and S4, as well as the corresponding 3RH2 contactor relays. No adapter plate or wiring harness needed; it snaps on. For motor control circuits drawing 0.1–0.2 A per contact (PLC inputs, relay coils), this leaves headroom. The mechanical life is 5 million operating cycles, typical for a snap-on auxiliary block in a contactor that itself may see 1–2 million cycles before replacement. Contact reliability is specified as one incorrect switching operation per 100 million at 5 V, 1 mA. That is the figure that matters when the block is used with solid-state inputs or low-power PLC cards — standard contacts can fail to close at those levels. The two NC contacts marked as solid-state compatible are the ones that meet this spec. Snap-on mounting onto the contactor front face — no DIN rail space consumed. The block measures 36 mm wide by 47.7 mm deep by 41.5 mm high, so it adds minimal projection beyond the contactor envelope. Spring-loaded terminals accept 2 x 0.5 to 2.5 mm² without ferrules, or 2 x 0.5 to 1.5 mm² with ferrules. AWG equivalents are 2 x 20 to 14. No screw torque to verify — consistent with panel-builder preference for spring-cage terminations on auxiliary wiring.","metaTitle":"Siemens 3RH2911-2NF22 SIRIUS Auxiliary Switch, 2NO+2NC, Spri","metaDescription":"Siemens 3RH2911-2NF22 SIRIUS auxiliary switch block, 2 NO + 2 NC, solid-state compatible, spring-loaded terminals, for 3RT2 contactors. Active production, IP20 front.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Note":"with 3RT2.2/3/4","Depth":"47.7 mm","Width":"36 mm","Height":"41.5 mm","at 24 V":"0.3 A","at 60 V":"0.3 A","During Storage":"-55 ... +80 °C","Leading Contact":"0","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"snap-on mounting","Lagging Switching":"0","Product Brand Name":"SIRIUS","Suitability For Use":"Contactor relay and power contactor","Instantaneous Contact":"2","With Core End Processing":"2x (0.5 ... 1.5 mm²)","Without Core End Processing":"2x (0.5 ... 2.5 mm²)","protection class IP on the front":"IP20","Surge Voltage Resistance Rated Value":"6 kV","at AWG cables for auxiliary contacts":"2x (20 ... 14)","Contact Reliability Of Auxiliary Contacts":"one incorrect switching operation of 100 million switching operations (5 V, 1 mA)","Mechanical Service Life (Operating Cycles) Typical":"5 000 000","Type Of Electrical Connection For Auxiliary And Control Circuit":"spring-loaded terminals","insulation voltage with degree of pollution 3 at AC rated value":"690 V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=689383&mlfb=3RH2911-2NF22","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RH2911-2NF22/alternatives.json"},"ai":{"faq":[{"question":"What does the note 'with 3RT2.2/3/4' mean?","answer":"It means this auxiliary switch block is designed to mount directly onto Siemens 3RT2 contactors in frame sizes S2, S3, and S4, and onto 3RH2 contactor relays of the same frame sizes."},{"question":"What is the depth of this auxiliary switch block?","answer":"47.7 mm, measured from the contactor mounting face outward."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RH2911-2NF22","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RH2911-2NF22 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}