{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RK1100-1CQ00-0AA3","brand":"Siemens","brandSlug":"siemens","productSlug":"3RK1100-1CQ00-0AA3","canonicalUrl":"https://aoctrl.com/siemens/3RK1100-1CQ00-0AA3","factsUrl":"https://aoctrl.com/api/mcp/products/3RK1100-1CQ00-0AA3","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3RK1100-1CQ00-0AA3 K60 digital output module, 4 PNP outputs, IP67, 60 x 152 x 29 mm, M12 sockets, built-in watchdog and short-circuit protection.","salesMarkdown":"## 4 PNP outputs in an IP67 field module The 3RK1100-1CQ00-0AA3 is a K60 compact digital output module with four PNP transistor outputs, rated for operation in the field at IP67. It has zero digital inputs — it's a pure output slice for the Siemens ET200pro or similar remote I/O system. Each output is short-circuit protected and the module carries a built-in watchdog that will reset the outputs if the fieldbus communication drops. The yellow LEDs on each socket give a quick visual on output state; the green LED shows auxiliary power is present. ## External supply and pinout — get the wiring right This module needs an external 20–30 VDC auxiliary supply (AUX POWER) for the output circuits, and that supply must be PELV per VDE 0106, protection class III. Don't try to power the outputs from the backplane bus — it won't work. The M12 socket assignments are specific: Socket 5 carries OUT1 on PIN4 and OUT2 on PIN2; Socket 6 carries OUT2 on PIN4; Socket 7 carries OUT3 on PIN4 and OUT4 on PIN2; Socket 8 carries OUT4 on PIN4. Sockets 1–4 are closed and unassigned. PIN5 on every M12 socket connects to the grounding wrist strap in the mounting plate. ## Mounting and environment — DIN rail or wall, IP67 sealed Mounts on standard DIN rail or directly to a wall using the K60 mounting plate (the module ships without the plate — order separately). Dimensions are 60 mm wide, 152 mm high, 29 mm deep — the slim profile fits tight junction boxes. IP67 means the sealed housing and M12 connectors survive washdown and dusty environments. Operating temperature range is -25 to +85 °C; storage from -40 to +85 °C. Shock rated at 15g for 11 ms — fine for machine-mounted applications near vibration sources.","metaTitle":"Siemens 3RK1100-1CQ00-0AA3 Remote I/O, 4 PNP Outputs, IP67","metaDescription":"Siemens 3RK1100-1CQ00-0AA3 digital output module, 4 PNP outputs, IP67, built-in watchdog and short-circuit protection. Requires external 20-30 VDC PELV supply.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Remote I/O & Fieldbus Modules"],"specifications":{"Type":"4 outputs","Depth":"29 mm","Width":"60 mm","title":"3RK1100-1CQ00-0AA3","Height":"152 mm","Note 2":"An external additional supply (AUX POWER) of 20 to 30 V DC is required for the supply of the output circuits. The additional supply must comply with VDE 0106 (PELV), protection class III.","Socket":"not assigned (closed)","Socket 2":"not assigned (closed)","Socket 3":"not assigned (closed)","Socket 4":"not assigned (closed)","Socket 5":"PIN4 = OUT1 (D0), PIN2 = OUT2 (D1)","Socket 6":"PIN4 = OUT2 (D1)","Socket 7":"PIN4 = OUT3 (D2), PIN2 = OUT4 (D3)","Socket 8":"PIN4 = OUT4 (D3)","Watchdog":"built-in","Addressing":"front addressing socket","ID/ID2 code":"1/F","description":"AS-i compact module K60 digital 4 DQ, IP67 4 x output, 2 A 24 V DC maximal 4 A for all outputs 4 x M12 socket Y-II assignment Mounting plate 3RK1901-0CA00 must be ordered separately","Delivery note":"the modules are delivered without mounting plate","Input Voltage":"20 ... 30 V","Input circuit":"PNP transistor","During Storage":"-40 ... +85 °C","Ground terminal":"PIN5 of each M12 socket is connected to the grounding wrist strap in the mounting plate using a pin","display of I/Os":"yellow LED","display of Uaux":"green LED","lifecycle_stage":"current","During Operation":"-25 ... +85 °C","Fastening Method":"standard rail mounting/wall mounting using mounting plate for K60 compact module","Shock Resistance":"15g / 11 ms","I/O configuration":"8","Number I/O sockets":"4","protection class IP":"IP67","Induction Protection":"built-in","Design Of The Product":"digital I/O modules for operation in the field, IP67 - K60","For Signal <1> Minimum":"6 mA","Short-Ciruit Protection":"built-in","With Signal <0> Maximum":"1.5 mA","Design Of The Slave Type":"standard slave","Number Of Digital Inputs":"0","Type Of Switching Output":"PNP transistor","Number Of Digital Outputs":"4","Outputs socket assignment":"3 = \"-\", 2/4 = output, 5 = ground terminal","Outputs aggregate current max":"4 A","Type Of Connection Technology":"2- and 3-wire technology","at ambient temperature 40 °C":"200 mA","Inputs switching level High min":"10 V","sensor supply using AS-Interface":"short-circuit and overload resistant","Type Of Voltage Of Output Voltages":"DC","display of AS-Interface/diagnostics":"green/red LED","AS interface total current input max":"270 mA","Outputs external power supply 24 V DC":"using black AS-Interface flat cable","Type Of Voltage Of The Input Voltages":"DC","Design Of The Pin Assignment Of The Inputs":"Y-II assignement","Property Of The Output Short-Circuit Proof":"Yes","Design Of The Pin Assignment Of The Outputs":"Y-II assignement","ampacity of the semiconductor output at DC-13 at 24 V":"2 A","Type Of Electrical Connection Of The Inputs And Outputs":"M12 screw-type terminals","operating voltage according to AS-Interface spezification":"26.5 ... 31.6 V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/df6d4eda1c684b753546618a461d26cd.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=309313&mlfb=3RK1100-1CQ00-0AA3"},"ai":{"faq":[{"question":"What is the output type and count on this module?","answer":"It has four PNP transistor outputs with built-in short-circuit protection and a watchdog. There are no digital inputs on this module."},{"question":"What power supply does the 3RK1100-1CQ00-0AA3 need?","answer":"It requires an external 20–30 VDC auxiliary supply (AUX POWER) for the output circuits, and that supply must be PELV per VDE 0106, protection class III."},{"question":"What is the IP rating and mounting method?","answer":"IP67 rated. Mounts on standard DIN rail or wall-mounted using the K60 mounting plate (sold separately). Dimensions are 60 x 152 x 29 mm."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RK1100-1CQ00-0AA3","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RK1100-1CQ00-0AA3 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}