{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RK1107-0BG00-2AA2","brand":"Siemens","brandSlug":"siemens","productSlug":"3RK1107-0BG00-2AA2","canonicalUrl":"https://aoctrl.com/siemens/3RK1107-0BG00-2AA2","factsUrl":"https://aoctrl.com/api/mcp/products/3RK1107-0BG00-2AA2","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3RK1107-0BG00-2AA2 AS-i SC22.5 Slimline Compact I/O module, 2 analog outputs, 22.5 mm width, IP20, spring-loaded terminals, screw and snap-on mounting.","salesMarkdown":"## 22.5 mm AS-i analog output slice The Siemens 3RK1107-0BG00-2AA2 is a Slimline Compact I/O module for control cabinet use, part of the AS-i SC22.5 family. It provides two analog outputs in a 22.5 mm wide housing, 100 mm tall and 120 mm deep, fitting standard DIN-rail panels where cabinet depth is the constraint. It operates as a standard AS-Interface slave with profile S-7.3.5, supporting the AS-Interface protocol natively. The slave address is set via a front addressing socket; the factory-default ID1 code is F and is changeable. ## Analog output range and resolution The two analog outputs cover a wide signal range: 0 to 20 mA, 4 to 20 mA, ±20 mA, 1 to 5 V, 0 to 10 V, and ±10 V, with 12-bit A/D resolution. The output variable is parameterizable, and the symmetrical temperature error is 0.01 %/K relative to the output range. An auxiliary external feed (AUX POWER) of 20 to 30 V DC is required to supply the output circuits, complying with IEC 60990 (PELV), protection class III. The auxiliary feed can supply up to 4 A total for the outputs. The output circuits can be powered either from the AS-Interface bus or from the auxiliary supply (U_AUX). When powered via AS-i Power24V, the module supports it and draws a maximum of 200 mA at 24 V. ## Mounting, wiring, and environmental limits The module mounts via screw and snap-on onto a DIN rail. Connections to the inputs and outputs use spring-loaded terminals, accepting solid conductors from 0.5 to 1.5 mm² (single or paired) and finely stranded conductors with or without core-end processing. Protection class is IP20, suitable for clean, dry control cabinet environments. Operating temperature range is -25 to +70 °C, with storage from -40 to +85 °C. Shock resistance is rated at 15 g / 11 ms for modules alone, or 10 g / 11 ms with the device connector attached.","metaTitle":"Siemens 3RK1107-0BG00-2AA2 AS-i SC22.5, 2 Analog Outputs","metaDescription":"Siemens 3RK1107-0BG00-2AA2 Slimline AS-i module, 2 analog outputs, 22.5 mm wide, IP20. Active production, sourced per RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Remote I/O & Fieldbus Modules"],"specifications":{"Depth":"120 mm","Solid":"1x (0.5 ... 1.5 mm²), 2x (0.5 ... 1.5 mm²)","Width":"22.5 mm","title":"3RK1107-0BG00-2AA2","Height":"100 mm","ID1 code":"F; Factory setting, changeable","description":"AS-i SlimLine Compact module SC22.5, IP20, analog 2AQ-C/V spring-loaded terminals 2 x analog output outputs switchable C/V overall width 22.5 mm","During Storage":"-40 ... +85 °C","at 30 V maximum":"200 mA","lifecycle_stage":"current","During Operation":"-25 ... +70 °C","Fastening Method":"screw and snap-on mounting","Shock Resistance":"15g / 11 ms (modules) or 10g / 11 ms (modules with device connector)","for AS-Interface":"2 A","Other Information":"An auxiliary external feed (AUX POWER) of between 20 and 30 V DC is necessary for supplying the output circuits. The auxiliary feed must comply with IEC 60990 (PELV), protection class III.","Product Designation":"Slimline Compact I/O module for use in the control cabinet","at AWG cables solid":"1x (20 ... 16), 2x (20 ... 16)","protection class IP":"IP20","Design Of The Product":"AS-i SC22.5, 2AQ voltage/current","acc. to DIN EN 61346-2":"K","at AWG cables stranded":"1x (20 ... 16), 2x (20 ... 16)","Number Of Analog Inputs":"0","Design Of The Slave Type":"standard slave","Number Of Analog Outputs":"2","Number Of Digital Inputs":"0","Number Of Digital Outputs":"0","AS-Interface slave profile":"S-7.3.5","Signal Range At Analog Output":"0 ... 20 mA; 4 ... 20 mA; +/- 20 mA; 1 ... 5 V; 0 ... 10 V; +/- 10 V","For External Auxiliary Voltage":"4 A","at 24 V with AS-i Power24V maximum":"200 mA","Type Of Voltage Supply At The Outputs":"AS interface or U_AUX","type of address setting of AS-i slaves":"via front addressing socket","Number Of Digital Inputs Safety-Related":"0","A/D resolution for analog inputs/outputs":"12 bit","Finely Stranded With Core End Processing":"1x (0,25 ... 1,0 mm²), 2x (0,25 ... 1,0 mm²)","Finely Stranded Without Core End Processing":"1x (0.5 ... 1.5 mm²), 2x (0.5 ... 1.5 mm²)","product function suitable for AS-i Power24V":"Yes","protocol is supported AS-Interface protocol":"Yes","Product Function Parameterizable Output Variable":"Yes","operating voltage acc. to AS-Interface specification":"18 ... 31.6 V","Type Of Electrical Connection Of The Inputs And Outputs":"Spring-loaded terminals","symmetrical temperature error per K relating to input range/output range":"0.01 %/K","Relative Symmetrical Linearity Error Relating To Input Range/Output Range":"0.08 %","Relative Symmetrical Operational Limit Relating To Input Range/Output Range":"1 %; full sclae","relative symmetrical basic error limit relating to input range/output range at 25 °C":"0.8 %","relative symmetrical repeat accuracy relating to input range/output range in settled state 25 °C":"0.1 %"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/70c10719cb3315cc9cc778667998dd1e.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=553080&mlfb=3RK1107-0BG00-2AA2"},"ai":{"faq":[{"question":"What analog output signal ranges does the 3RK1107-0BG00-2AA2 support?","answer":"The two analog outputs support 0 to 20 mA, 4 to 20 mA, ±20 mA, 1 to 5 V, 0 to 10 V, and ±10 V, with 12-bit resolution. The output variable is parameterizable."},{"question":"Does the 3RK1107-0BG00-2AA2 require an external power supply for the outputs?","answer":"Yes, an auxiliary external feed (AUX POWER) of 20 to 30 V DC is necessary for supplying the output circuits. It must comply with IEC 60990 (PELV), protection class III, and can supply up to 4 A total."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RK1107-0BG00-2AA2","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RK1107-0BG00-2AA2 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}