{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RK1107-2BQ40-0AA3","brand":"Siemens","brandSlug":"siemens","productSlug":"3RK1107-2BQ40-0AA3","canonicalUrl":"https://aoctrl.com/siemens/3RK1107-2BQ40-0AA3","factsUrl":"https://aoctrl.com/api/mcp/products/3RK1107-2BQ40-0AA3","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS AS-Interface K60 compact module, 3RK1107-2BQ40-0AA3, analog output module with 2 voltage outputs, IP67, M12 connections.","salesMarkdown":"The Siemens 3RK1107-2BQ40-0AA3 is an AS-Interface compact module from the K60 family — an analog output module for voltage values, designed to sit out in the field rather than inside a control cabinet. It gives you two analog voltage outputs, each configurable for ±10 V, 0 to 10 V, or 1 to 5 V ranges, driving up to 30 mA per actuator. That makes it the piece that takes a digital AS-i bus command and turns it into a real voltage signal for a valve positioner, a variable-speed drive setpoint, or a proportional regulator. The module is an analog AS-Interface slave, drawing its power straight from the AS-i cable at 26.5 to 31.6 V. Maximum current draw from the profile conductors at 30 V is 160 mA, so it won't overload a standard AS-i power supply even on a populated segment. The 12-bit resolution on the analog outputs gives you about 4.9 mV per step on the 0–10 V range — enough granularity for most process setpoints without overshooting the loop. ## Built for the grease, not the cabinet Rated IP67, this module is sealed against dust and water jets — it belongs on a machine frame, a conveyor leg, or a washdown station, not behind a panel door. The housing is the K60 compact form factor: 152 mm tall, 60 mm wide, 29 mm deep. That footprint is meant for standard rail mounting or wall mounting using a separate mounting plate (3RK1901-0CA00, ordered separately). Connections to the outside world go through M12 screw-type terminals — the standard fieldbus connector for sensors and actuators in wet or dirty environments. The two voltage outputs each get their own M12 socket, and the AS-i bus comes in through a separate M12 connection. On the module face you get a green LED for AS-Interface communication status and a red LED for fault indication. The ID code is set to 3 and the I/O configuration to 7 — these are the AS-i profile settings that tell the master what kind of slave it's talking to. The mounting plate 3RK1901-0CA00 is a separate order line — make sure it's on the BOM if you're mounting to a flat surface rather than DIN rail. The module itself clips onto the plate, which then screws to the machine frame. Temperature range covers -20 to +60 °C during operation and -40 to +85 °C in storage — fine for most factory-floor environments short of a foundry or freezer tunnel.","metaTitle":"Siemens 3RK1107-2BQ40-0AA3 AS-Interface Analog Output Module","metaDescription":"Siemens 3RK1107-2BQ40-0AA3 AS-Interface K60 analog output module, 2 voltage outputs ±10V/0-10V/1-5V, IP67, active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Remote I/O & Fieldbus Modules"],"specifications":{"Type":"2 outputs","Depth":"29mm","FAULT":"red LED","Width":"60mm","title":"3RK1107-2BQ40-0AA3","Height":"152mm","ID code":"3","Profile":"7.3","Voltage":"Yes","description":"AS-i compact module K60 analog 2 AQ, IP67 2x 1 output, Voltage +/- 10 V 1..5 V for 2-wire actuators 2 x M12 socket Mounting plate 3RK1901-0CA00 must be ordered separately","AS-Interface":"green LED","During Storage":"-40 ... +85°C","Type of device":"analog output modules for voltage values","Channels active":"1 and 2","Output Quantity":"V","lifecycle_stage":"current","During Operation":"-20 ... +60°C","Fastening Method":"standard rail mounting/wall mounting using mounting plate for K60 compact module","I/O configuration":"7","protection class IP":"IP67","Design Of The Product":"analog I/O modules for operation in the field, IP67 - K60","Measuring/output range":"+-10 V/ 0 ... 10 V / 1 .. 5 V","Measuring/output value":"voltage","2 Voltage Actuators Max":"30mA","Number Of Analog Inputs":"0","Design Of The Slave Type":"analog slave","Number Of Analog Outputs":"2","A/D resolution for analog inputs/outputs":"12bit","Product Function Parameterizable Output Variable":"Yes","Type Of Electrical Connection Of The Inputs And Outputs":"M12 screw-type terminals","operating voltage according to AS-Interface spezification":"26.5 ... 31.6V","consumed current from profile conductors of the AS-Interface at 30 V maximum":"160mA"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$228.60","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/20635d7c34409e083808ef3f6a4b38a9.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=216828&mlfb=3RK1107-2BQ40-0AA3"},"ai":{"faq":[{"question":"What voltage outputs does this module provide?","answer":"The two analog outputs are configurable for ±10 V, 0 to 10 V, or 1 to 5 V ranges, each sourcing up to 30 mA. The output type is voltage, not current — if you need 4–20 mA, this isn't the module."},{"question":"Where can I buy 3RK1107-2BQ40-0AA3?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm delivery commitment."},{"question":"What is the mounting plate requirement?","answer":"The module mounts to a standard rail or to a flat surface using the separate mounting plate 3RK1901-0CA00. That plate is not included with the module and must be ordered as a separate line item."},{"question":"Will 3RK1107-2BQ40-0AA3 drop into a panel designed for a contactor like 3RT5046-1AM00?","answer":"No — this is an AS-Interface field module, not a panel-mount contactor. The 3RT5046-1AM00 is a SIRIUS power contactor for motor switching inside a cabinet. The 3RK1107-2BQ40-0AA3 is an IP67 field I/O module that mounts on a machine frame or DIN rail outside the panel. Different footprint, different wiring, different function."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RK1107-2BQ40-0AA3","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RK1107-2BQ40-0AA3 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}