{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RK1300-0AS10-0AA3","brand":"Siemens","brandSlug":"siemens","productSlug":"3RK1300-0AS10-0AA3","canonicalUrl":"https://aoctrl.com/siemens/3RK1300-0AS10-0AA3","factsUrl":"https://aoctrl.com/api/mcp/products/3RK1300-0AS10-0AA3","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS EM 300 EDS electronic direct starter for ET 200X, 3RK1300-0AS10-0AA3, setting range 0.6…2.18 A, AC-3 0.8 kW at 400 V, solid-state switching and protection, IP65, with brake contact and PROFIBUS DP.","salesMarkdown":"The Siemens 3RK1300-0AS10-0AA3 is an EM 300 EDS electronic direct starter designed for the ET 200X distributed I/O family. It's a solid-state motor starter that combines a direct starter, motor protection, and switching in one IP65 enclosure — no separate contactor and overload relay needed. The setting range covers 0.6 to 2.18 A, which translates to 0.18 to 0.8 kW at 400 V AC-3 duty. That AC-3 rating means it's sized for starting squirrel-cage motors under load, not just resistive heaters. The solid-state switching contact means no mechanical wear on the main path — the starter handles millions of operations without contact erosion. Motor protection is also solid-state, so the trip curve stays consistent regardless of ambient temperature swings inside the enclosure. The unit communicates via PROFIBUS DP, so it plugs straight into a Siemens ET 200X station and reports status, current draw, and fault codes over the bus. ## Where this starter fits a line This is a distributed motor starter for a remote I/O cabinet or a machine-mounted junction box. The IP65 rating means the electronics are sealed against washdown and dust — fine for food-and-bev packaging lines, conveyor transfer stations, or any area where a central MCC panel isn't practical. The 134 mm depth, 140 mm width, and 270 mm height fit the ET 200X form factor; it mounts directly on the system rail alongside the ET 200X interface module and I/O slices. Power connection uses tab terminals (fast-on style) for the main circuit. Short-circuit protection is via external fuses — the unit itself has a breaking capacity of 100 A at 400 V, but the upstream fuse must be coordinated per the manufacturer's table. The starter includes a motor brake output, so it can handle a holding brake on vertical-axis motors without a separate brake rectifier. The 0.6 to 2.18 A setting range covers small motors — think 0.18 kW up to 0.8 kW at 400 V AC-3. The 400 to 500 V operating voltage covers standard European 400 V three-phase networks and 480 V North American supplies. Ambient temperature range of 0 to 55 °C is typical for enclosed cabinets; no derating needed unless you're stacking units side-by-side without airflow. The minimum disconnection time is 1 second, so it's not for high-speed reversing applications — this is a start/run/stop starter, not a jogging device.","metaTitle":"Siemens 3RK1300-0AS10-0AA3 EM 300 EDS Direct Starter, 0.6-2.","metaDescription":"Siemens 3RK1300-0AS10-0AA3 EM 300 EDS electronic direct starter for ET 200X. Solid-state motor protection, 0.6-2.18A setting range, 0.8kW at 400V AC-3, IP65, PROFIBUS DP. Sourced t","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Remote I/O & Fieldbus Modules"],"specifications":{"Depth":"134mm","Width":"140mm","Height":"270mm","Maximum":"0.8kW","Minimum":"0.18kW","Initial Value":"0.6A","Type of voltage":"DC","lifecycle_stage":"current","Full-scale value":"2.18A","Protection class IP":"IP65","PROFIBUS DP protocol":"Yes","AS-interface protocol":"No","Design of the product":"direct starter","Type of the motor protection":"solid-state","at AC-3 at 400 V rated value":"0.8kW","Operating voltage rated value":"400 ... 500V","Design of the switching contact":"solid-state","Design of short-circuit protection":"fuse","Product function Bus communication":"Yes","Ambient temperature during operation":"0 ... 55°C","Product component Motor brake output":"Yes","Equipment marking acc. to DIN EN 61346-2":"Q","Type of electrical connection for main current circuit":"tab terminals","Maximum short-circuit current breaking capacity (Icu) at 400 V rated value":"100A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=114746&mlfb=3RK1300-0AS10-0AA3","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RK1300-0AS10-0AA3/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RK1300-0AS10-0AA3 and get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is the setting range and motor power for 3RK1300-0AS10-0AA3?","answer":"The setting range is 0.6 to 2.18 A, covering motors from 0.18 kW up to 0.8 kW at 400 V AC-3 duty."},{"question":"Does 3RK1300-0AS10-0AA3 include PROFIBUS DP communication?","answer":"Yes, PROFIBUS DP protocol is built in — no separate gateway or communication module required. It connects directly to an ET 200X station."},{"question":"What is the IP rating and enclosure protection?","answer":"The starter carries IP65 protection, meaning it is dust-tight and protected against water jets from any direction. Suitable for washdown environments."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RK1300-0AS10-0AA3","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RK1300-0AS10-0AA3 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}