{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RK1300-0BS10-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RK1300-0BS10-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3RK1300-0BS10-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3RK1300-0BS10-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3RK1300-0BS10-0AA0, direct starter, solid-state motor protection, 6 A AC-3 at 400 V, 2.2 kW, IP65, PROFIBUS DP.","salesMarkdown":"The Siemens 3RK1300-0BS10-0AA0 is a direct starter with solid-state switching contacts and integrated motor protection, rated for 6 A in AC-3 duty at 400 V — enough to handle a 2.2 kW motor on a conveyor, pump, or fan. The solid-state design means no contact wear from repetitive starts, which is the main reason you'd spec this over a conventional contactor for high-cycle applications. Control supply is 24 V DC, with a tolerance of 20.4 to 28.8 V DC. That's a standard PLC-side voltage; the 24 V bus powers the electronics and the PROFIBUS DP interface. No digital I/O on board — this starter is a pure motor actuator on the bus, not a local I/O block. The 270 mm height, 140 mm width, and 134 mm depth are the enclosure footprint; plan for that volume in the panel layout. ## Deployment context This direct starter connects to the main energy infeed and load-side outgoing feeder via sockets conforming to ISO 23570 — that's a standardized interface for modular motor starters in distributed automation architectures. Supply voltage and communication (PROFIBUS DP) come through the backplane bus, so the unit is designed for a multi-station rail system, not as a standalone panel-mount device. The three-pole main current circuit handles three-phase motor loads.","metaTitle":"Siemens 3RK1300-0BS10-0AA0 Direct Starter, 6A AC-3 at 400V,","metaDescription":"Siemens 3RK1300-0BS10-0AA0 direct starter, solid-state motor protection, rated 6A AC-3 at 400V (2.2kW), IP65 enclosure, PROFIBUS DP. Current lifecycle stage. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Remote I/O & Fieldbus Modules"],"specifications":{"Depth":"134 mm","Width":"140 mm","at DC":"24 ... 24 V","Height":"270 mm","Type of voltage":"DC","lifecycle_stage":"current","During Operation":"0 ... 55 °C","Bus communication":"Yes","at DC rated value":"20.4 ... 28.8 V","Protection class IP":"IP65","at 400 V rated value":"100 A","Design of the product":"direct starter","For Main Energy Infeed":"socket according to ISO23570","Supply voltage 1 at DC":"24 ... 24 V","Short circuit protection":"Yes","For Digital Input Signals":"0","For Digital Output Signals":"0","For Main Energy Transmission":"socket according to ISO23570","For Supply Voltage Line-Side":"via backplane bus","Type of the motor protection":"solid-state","at AC-3 at 400 V rated value":"6 A","For Load-Side Outgoing Feeder":"socket according to ISO23570","Operating voltage rated value":"400 ... 500 V","Digital Inputs Parameterizable":"No","For Communication Transmission":"via backplane bus","Of The Communication Interface":"via backplane bus","Design of the switching contact":"solid-state","Digital Outputs Parameterizable":"No","For Supply Voltage Transmission":"via backplane bus","Design of short-circuit protection":"fuse","Product component Motor brake output":"No","Reference code acc. to DIN EN 61346-2":"Q","Reference code acc. to DIN EN 81346-2":"Q","Control supply voltage at DC rated value":"20.4 ... 28.8 V","Number of poles for main current circuit":"3","Design of the interface PROFINET protocol":"No","Protocol is supported PROFIBUS DP protocol":"Yes","Protocol is supported AS-Interface protocol":"No","Operating power at AC-3 at 400 V rated value":"2.2 kW","Type of voltage of the control supply voltage":"DC","Type of electrical connection for main current circuit":"tab terminals","Adjustable pick-up value current of the current-dependent overload release":"2 ... 5.95 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=451918&mlfb=3RK1300-0BS10-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RK1300-0BS10-0AA0/alternatives.json"},"ai":{"faq":[{"question":"What is the AC-3 motor rating of this starter?","answer":"The AC-3 rating is 6 A at 400 V, corresponding to 2.2 kW motor power. This is the motor-switching current — the figure that decides fit for your induction motor load."},{"question":"Where can I buy 3RK1300-0BS10-0AA0 and how is it quoted?","answer":"This part is sourced to order through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time."},{"question":"What is the enclosure protection rating?","answer":"IP65 — dust-tight and protected against water jets, suitable for washdown environments."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RK1300-0BS10-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RK1300-0BS10-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}