{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RK1300-0BS10-1AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RK1300-0BS10-1AA0","canonicalUrl":"https://aoctrl.com/siemens/3RK1300-0BS10-1AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3RK1300-0BS10-1AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RK1300-0BS10-1AA0, electronic reversing starter, solid-state motor protection, setting range 2.0-5.95A, 2.2kW at 400V AC-3, IP65, PROFIBUS DP, tab terminals.","salesMarkdown":"The Siemens 3RK1300-0BS10-1AA0 is an electronic reversing starter from the SIRIUS family, designed as a compact motor-starting and protection unit for ET 200X distributed I/O environments. It integrates solid-state motor protection with a setting range of 2.0 to 5.95 A, delivering up to 2.2 kW at 400 V under AC-3 duty — the standard motor-switching load profile for squirrel-cage induction motors. The solid-state switching contacts mean no mechanical wear on the main power path, so the unit handles the full electrical life without contact replacement. The IP65 enclosure allows direct mounting in washdown or dusty environments without a separate cabinet — suitable for food-and-bev lines, packaging cells, or any area where hose-down cleaning is routine. The PROFIBUS DP interface ties it into the ET 200X remote I/O backbone, so reversing commands and diagnostic data travel over the fieldbus without hardwired control wires. The AC-3 rating of 2.2 kW at 400 V is the figure that governs motor sizing: it tells you the starter can switch a 3-phase induction motor up to that power under starting and running conditions. The setting range of 2.0 to 5.95 A means the overload protection is adjustable within that band — you dial it to the motor's full-load current, not the starter's maximum. The minimum motor power of 0.75 kW sets the lower bound; below that, the solid-state trip curve may not coordinate with the motor's thermal characteristics. The design requires fuses for short-circuit protection; the 100 A figure assumes the correct upstream fuse coordination per the manufacturer's table. Operating temperature range is 0 to 55 °C. The DC control voltage powers the internal electronics and fieldbus interface. The 9-pole power connection handles the main circuit wiring via tab terminals — a standard fast-on connection that mates with matching receptacles on the ET 200X base unit. ## Deployment context This starter mounts directly onto an ET 200X distributed I/O station — it is not a stand-alone DIN-rail component. The 134 mm depth, 140 mm width, and 270 mm height define the envelope that projects from the ET 200X base; panel builders must account for that protrusion when laying out the enclosure depth and cable-entry zones.","metaTitle":"Siemens 3RK1300-0BS10-1AA0 Electronic Reversing Starter, 2.2","metaDescription":"Siemens SIRIUS 3RK1300-0BS10-1AA0 electronic reversing starter, solid-state motor protection, 2.0-5.95A setting range, 2.2kW at 400V AC-3, IP65, PROFIBUS DP. Current production. So","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Remote I/O & Fieldbus Modules"],"specifications":{"Depth":"134mm","Width":"140mm","Height":"270mm","Maximum":"2.2kW","Minimum":"0.75kW","Initial Value":"2A","Type of voltage":"DC","lifecycle_stage":"current","Full-scale value":"5.95A","Protection class IP":"IP65","PROFIBUS DP protocol":"Yes","AS-interface protocol":"No","Design of the product":"reversing starter","Type of the motor protection":"solid-state","at AC-3 at 400 V rated value":"2.2kW","Operating voltage rated value":"400 ... 500V","Design of the switching contact":"solid-state","Design of short-circuit protection":"fuse","Product function Bus communication":"Yes","Ambient temperature during operation":"0 ... 55°C","Product component Motor brake output":"No","Equipment marking acc. to DIN EN 61346-2":"Q","Type of electrical connection for main current circuit":"tab terminals","Maximum short-circuit current breaking capacity (Icu) at 400 V rated value":"100A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=440635&mlfb=3RK1300-0BS10-1AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RK1300-0BS10-1AA0/alternatives.json"},"ai":{"faq":[{"question":"What is the setting range and motor power for 3RK1300-0BS10-1AA0?","answer":"The overload setting range is 2.0 to 5.95 A, covering motors from 0.75 kW to 2.2 kW at 400 V AC-3."},{"question":"Does 3RK1300-0BS10-1AA0 include PROFIBUS DP communication?","answer":"Yes, it supports PROFIBUS DP protocol for fieldbus integration with the ET 200X system."},{"question":"What is the IP rating and where can this starter be mounted?","answer":"IP65 allows direct mounting in washdown or dusty environments on the machine frame via the ET 200X base."},{"question":"How do I get current pricing and availability for 3RK1300-0BS10-1AA0?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RK1300-0BS10-1AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RK1300-0BS10-1AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}