{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RK1300-1DS01-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RK1300-1DS01-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3RK1300-1DS01-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3RK1300-1DS01-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS EM 300 DS direct starter, 3RK1300-1DS01-0AA0, electromechanical, setting range 2.2...3.2A, AC-3 rated 1.1kW at 400V, IP65 enclosure, PROFIBUS DP communication, for ET 200X distributed I/O systems.","salesMarkdown":"The Siemens 3RK1300-1DS01-0AA0 is an EM 300 DS direct starter designed for the ET 200X distributed I/O system — an electromechanical motor starter that combines a contactor, overload relay, and short-circuit protection in one IP65-rated enclosure for mounting directly on the machine, not back in the panel. It's rated for AC-3 duty at 1.1 kW on a 400 V supply, with a current setting range of 2.2 to 3.2 A via a bimetal overload relay, and carries a maximum short-circuit breaking capacity of 50 A at 400 V. The IP65 rating means the enclosure and connections withstand hose-directed water and dust ingress, so it's suited for washdown zones in food-and-bev or chemical processing lines where a panel-mounted starter would be impractical. ## Communication and integration This starter communicates over PROFIBUS DP, letting the ET 200X remote I/O head handle start/stop commands and fault feedback without running individual control wires back to the PLC cabinet. The main current circuit connects via tab terminals — no screw terminals on the power side, so verify your motor feeder cable ends match before installation. Dimensions are 140 mm wide, 270 mm high, and 134 mm deep — sized to the ET 200X modular block format, so it clips onto the same mounting rail and aligns with the bus connectors of adjacent modules. The 2.2 to 3.2 A setting range covers small three-phase motors (up to 1.1 kW at 400 V) — the bimetal overload tracks motor heating, so set it to the motor nameplate FLA, not the starter's maximum. Operating ambient temperature is 0 to 55 °C, so it's fine inside a non-conditioned enclosure on the plant floor but not for freezer or outdoor direct-sun applications.","metaTitle":"Siemens 3RK1300-1DS01-0AA0 EM 300 DS Direct Starter, 2.2-3.2","metaDescription":"Siemens 3RK1300-1DS01-0AA0 EM 300 DS direct starter for ET 200X. 2.2-3.2A setting range, 1.1kW at 400V AC-3, IP65, PROFIBUS DP. Current lifecycle status: active. Available to order","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Remote I/O & Fieldbus Modules"],"specifications":{"Depth":"134mm","Width":"140mm","Height":"270mm","Maximum":"1.1kW","Minimum":"1.1kW","Initial Value":"2.2A","Type of voltage":"DC","lifecycle_stage":"current","Full-scale value":"3.2A","Protection class IP":"IP65","PROFIBUS DP protocol":"Yes","AS-interface protocol":"No","Design of the product":"direct starter","Type of the motor protection":"bimetal","at AC-3 at 400 V rated value":"1.1kW","Operating voltage rated value":"400 ... 500V","Design of the switching contact":"electromechanical","Design of short-circuit protection":"circuit-breakers","Product function Bus communication":"Yes","Ambient temperature during operation":"0 ... 55°C","Product component Motor brake output":"No","Equipment marking acc. to DIN EN 61346-2":"Q","Type of electrical connection for main current circuit":"tab terminals","Maximum short-circuit current breaking capacity (Icu) at 400 V rated value":"50A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=524155&mlfb=3RK1300-1DS01-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RK1300-1DS01-0AA0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy the 3RK1300-1DS01-0AA0?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution channels; availability and current pricing are confirmed at quote time."},{"question":"What is the current setting range on this starter?","answer":"The bimetal overload is adjustable from 2.2 A to 3.2 A, covering motors up to 1.1 kW at 400 V AC-3."},{"question":"Will the 3RK1300-1DS01-0AA0 fit in a panel designed for a 3RT5065-6AB36 contactor?","answer":"No — this is a different form factor entirely. The 3RK1300-1DS01-0AA0 is a 140 mm wide × 270 mm high × 134 mm deep IP65 direct starter for the ET 200X distributed system, while the 3RT5065-6AB36 is a 145 mm wide × 210 mm high × 202 mm deep panel-mount contactor with screw terminals. Different mounting rail, different bus architecture, different wiring."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RK1300-1DS01-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RK1300-1DS01-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}