{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RK1300-1HS01-1AA3","brand":"Siemens","brandSlug":"siemens","productSlug":"3RK1300-1HS01-1AA3","canonicalUrl":"https://aoctrl.com/siemens/3RK1300-1HS01-1AA3","factsUrl":"https://aoctrl.com/api/mcp/products/3RK1300-1HS01-1AA3","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3RK1300-1HS01-1AA3, EM 300 RS reversing starter for ET 200X, electromechanical, setting range 5.5...8.0A, AC-3 3.0kW/400V, with brake contact, IP65, PROFIBUS DP.","salesMarkdown":"The Siemens 3RK1300-1HS01-1AA3 is an electromechanical reversing starter from the EM 300 RS family, designed for the ET 200X distributed I/O system. It combines a reversing contactor, motor protection via bimetal overload relay, and PROFIBUS DP communication in a single IP65-rated enclosure. Rated for 3 kW at AC-3 duty on a 400 V supply, it handles reversing motor loads up to that power — think conveyor direction changes, pump valve actuation, or any application needing forward/reverse control from a single device. The setting range of 5.5 to 8 A lets you dial in the exact full-load current of the motor. The IP65 rating means the entire unit — enclosure, terminals, and PROFIBUS connection — withstands washdown and dust ingress, so it mounts directly on-machine or in harsh environments without a separate cabinet. The AC-3 rating of 3 kW at 400 V is the motor-switching capability under normal starting conditions (up to 8x inrush). The bimetal overload relay is adjustable via the 5.5–8 A setting range. Set it to match the motor nameplate FLA. PROFIBUS DP onboard means this starter communicates directly with the ET 200X backplane — no separate gateway or I/O block needed for start/stop and feedback. The brake contact output (rated for internally supplied DC brakes) handles motor holding brakes common in vertical-axis applications. Operating temperature range of 0 to 55 °C covers most industrial floor conditions. Mounts directly on machine frames or in IP65-rated enclosures via its 270 x 140 x 134 mm (H x W x D) footprint. The 9-pole motor feeder and 9-pole power connection mate with the ET 200X backplane — no additional wiring between starter and I/O head. PROFIBUS DP daisy-chains through the unit.","metaTitle":"Siemens 3RK1300-1HS01-1AA3 reversing starter, 5.5-8A, IP65,","metaDescription":"Siemens 3RK1300-1HS01-1AA3 EM 300 RS reversing starter for ET 200X. Rated 3kW at AC-3, 400V. Setting range 5.5-8A. IP65, PROFIBUS DP, brake contact. Current production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Remote I/O & Fieldbus Modules"],"specifications":{"Depth":"134mm","Width":"140mm","Height":"270mm","Maximum":"3kW","Minimum":"3kW","Initial Value":"5.5A","Type of voltage":"DC","lifecycle_stage":"current","Full-scale value":"8A","Protection class IP":"IP65","PROFIBUS DP protocol":"Yes","AS-interface protocol":"No","Design of the product":"reversing starter","Type of the motor protection":"bimetal","at AC-3 at 400 V rated value":"3kW","Operating voltage rated value":"400 ... 500V","Design of the switching contact":"electromechanical","Design of short-circuit protection":"circuit-breakers","Product function Bus communication":"Yes","Ambient temperature during operation":"0 ... 55°C","Product component Motor brake output":"Yes","Equipment marking acc. to DIN EN 61346-2":"Q","Type of electrical connection for main current circuit":"tab terminals","Maximum short-circuit current breaking capacity (Icu) at 400 V rated value":"50A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=101956&mlfb=3RK1300-1HS01-1AA3","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RK1300-1HS01-1AA3/alternatives.json"},"ai":{"faq":[{"question":"What is the setting range and what motor can it handle?","answer":"The setting range is 5.5 to 8 A, and at AC-3 duty on 400 V it is rated for 3 kW motor loads. The bimetal overload relay provides motor protection within that range."},{"question":"Does it include a brake output?","answer":"Yes, it has a motor brake output component for internally supplied DC brakes, controlled via the reversing starter."},{"question":"What communication protocol does it support?","answer":"It supports PROFIBUS DP for direct communication with the ET 200X distributed I/O system. AS-Interface is not supported."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RK1300-1HS01-1AA3","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RK1300-1HS01-1AA3 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}