{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RK1301-0AB10-0AA4","brand":"Siemens","brandSlug":"siemens","productSlug":"3RK1301-0AB10-0AA4","canonicalUrl":"https://aoctrl.com/siemens/3RK1301-0AB10-0AA4","factsUrl":"https://aoctrl.com/api/mcp/products/3RK1301-0AB10-0AA4","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC motor starter, direct starter design, 3RK1301-0AB10-0AA4, PROFINET, adjustable trip class 10/20, 50 kA SCCR at 400 V.","salesMarkdown":"## What this SIMATIC motor starter gives you The Siemens SIMATIC 3RK1301-0AB10-0AA4 is a direct motor starter — meaning it handles full-voltage starting for three-phase motors without reversing. It's part of the SIMATIC motor starter family, designed to integrate into PROFINET networks so you get diagnostics and control right over the fieldbus. The adjustable trip class is the feature to pay attention to here: you can set it to CLASS 10 or CLASS 20. CLASS 10 trips faster (within 10 seconds at locked-rotor current), which protects motors with shorter thermal time constants — think pumps or fans that don't tolerate prolonged stall. CLASS 20 gives you more headroom for high-inertia loads like conveyors or crushers that need a longer acceleration ramp. That adjustability means one part number covers both scenarios, so you're not stocking two separate overload relays. It's certified to IEC 60664 and IEC 61131 with a pollution degree of 3 at 400 V, meaning it's rated for the dusty, conductive environment you'd expect in a real factory floor panel. This starter mounts by plugging onto a terminal module — no DIN-rail clips, no screw-down feet. The terminal module is the base that carries the power wiring; the starter module itself snaps onto it. That means you can pre-wire the terminal module during panel build, then plug the starter in after the panel is powered down for commissioning. It's a clean separation of power and control wiring. Physical envelope: 65 mm wide, 290 mm high, 150 mm deep. That 65 mm width is a single unit width — it fits in a standard 600 mm wide enclosure with room for nine more starters side by side. The 290 mm height is tall enough that you'll want to check your enclosure's internal backplate clearance, especially if you're mounting a busbar system above it. Mounting position is flexible: vertical or horizontal. If you're tight on vertical space in a shallow panel, horizontal mounting works, but keep in mind that the terminal module's screw-type terminals for the main power infeed need tool access from the front. The starter has 2 digital inputs wired through the control module. I/O mapping is 2 bytes for inputs and 2 bytes for outputs over PROFINET. Supply voltage is 24 V DC nominal, with a tolerance of 20.4 V to 28.8 V. Maximum permissible voltage is 28.8 V. PROFINET is the primary fieldbus, but it also supports PROFIBUS DP — both protocols are listed. If your plant runs a mixed network with some lines on PROFIBUS and others on PROFINET, this starter can handle either, but you'll need the correct control module variant for the bus type. ## Environmental limits and mechanicals Operating temperature range is 0 to 60 °C — that's typical for an IP20 panel-mounted device. Vibration resistance is 2g continuous; shock resistance is 5g for 11 ms. That's enough for most industrial environments but not for direct mounting on a vibrating machine frame — if you're mounting it on a press or a large compressor, you'll want to isolate the panel. Maximum operating frequency is 750 operations per hour. Power dissipation with bypass circuit is 5.6736 W; without bypass it is 5.674 W.","metaTitle":"Siemens SIMATIC 3RK1301-0AB10-0AA4 Motor Starter, PROFINET,","metaDescription":"Siemens SIMATIC 3RK1301-0AB10-0AA4 direct motor starter. PROFINET, adjustable Class 10/20, 50 kA at 400 V. Current production. Sourced to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Remote I/O & Fieldbus Modules"],"specifications":{"Depth":"150 mm","Width":"65 mm","at DC":"24 ... 24 V","Height":"290 mm","Trip Class":"CLASS 10 and 20 adjustable","Direct Start":"Yes","Of The Inputs":"2 byte","During Storage":"-40 ... +70 °C","Of The Outputs":"2 byte","lifecycle_stage":"current","During Operation":"0 ... 60 °C","During Transport":"-40 ... +70 °C","Fastening Method":"pluggable on terminal module","Reverse Starting":"No","Shock Resistance":"5g / 11 ms","Mounting Position":"vertical, horizontal","PROFINET protocol":"Yes","at DC rated value":"20.4 ... 28.8 V","Product Brand Name":"SIMATIC","Type Of Assignment":"2","Degree Of Pollution":"3 at 400 V, 2 at 500 V according to IEC60664 (IEC61131)","Maximum Permissible":"28.8 V","Minimum Permissible":"20.4 V","Product Designation":"Motor starters","With Bypass Circuit":"5.6736 W","PROFIBUS DP protocol":"Yes","Vibration Resistance":"2g","at 400 V rated value":"50 kA","Design Of The Product":"direct starter","For Main Energy Infeed":"screw-type terminals","Without Bypass Circuit":"5.674 W","supply voltage 1 at DC":"24 ... 24 V","Number Of Digital Inputs":"2","For Digital Input Signals":"0","For Digital Output Signals":"0","brake control with 24 V DC":"No","1 For Digital Input Signals":"using control module","2 For Digital Input Signals":"using control module","Operating Frequency Maximum":"750 1/h","brake control with 180 V DC":"No","brake control with 230 V AC":"No","brake control with 500 V DC":"No","For Main Energy Transmission":"via energy bus","For Supply Voltage Line-Side":"via backplane bus","Type Of The Motor Protection":"solid-state","For Load-Side Outgoing Feeder":"Screw-type terminals","Operating Voltage Rated Value":"200 ... 400 V","Substance Prohibitance (Date)":"10/26/2016","supports PROFIenergy shutdown":"No","Digital Inputs Parameterizable":"Yes","For Communication Transmission":"via backplane bus","Insulation Voltage Rated Value":"500 V","Of The Communication Interface":"via backplane bus","Design Of The Switching Contact":"electromechanical","Digital Outputs Parameterizable":"No","For Supply Voltage Transmission":"via backplane bus","Operating Frequency 1 Rated Value":"50 Hz","Operating Frequency 2 Rated Value":"60 Hz","Design Of Short-Circuit Protection":"circuit-breakers","Product Function Bus Communication":"Yes","Product Function On-Site Operation":"Yes","Relative Humidity During Operation":"5 ... 95 %","Product Component Motor Brake Output":"Yes","Surge Voltage Resistance Rated Value":"6 kV","supports PROFIenergy measured values":"No","EMC immunity according to IEC 60947-1":"corresponds to degree of severity 3, ambience A (industrial sector)","Type Of Voltage Of The Supply Voltage":"DC","due to burst according to IEC 61000-4-4":"2 kV on voltage supply, inputs and outputs","reference code according to IEC 81346-2":"Q","Number Of Poles For Main Current Circuit":"3","control supply voltage at DC rated value":"20.4 ... 28.8 V","Product Function Short Circuit Protection":"Yes","design of the interface PROFINET protocol":"Yes","with low demand rate according to SN 31920":"100 FIT","protocol is supported AS-Interface protocol":"No","with high demand rate according to SN 31920":"75 %","operating power at AC-3 at 400 V rated value":"1.1 kW","At The Manufacturer-Specific Device Interface":"plug","Type Of Voltage Of The Control Supply Voltage":"DC","EMC emitted interference according to IEC 60947-1":"CISPR11, ambience A (industrial sector)","Product Extension Braking Module For Brake Control":"Yes","Relative Negative Tolerance Of The Operating Frequency":"10 %","Relative Positive Tolerance Of The Operating Frequency":"10 %","Type Of Electrical Connection For Main Current Circuit":"screw-type terminals","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","operating range relative to the operating voltage at AC at 50 Hz":"200 ... 440 V","operating voltage at AC at 60 Hz according to CSA and UL rated value":"600 V","Mechanical Service Life (Operating Cycles) Of The Main Contacts Typical":"100 000","Maximum Permissible Voltage For Safe Isolation Between Main And Auxiliary Circuit":"400 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.3 ... 3 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=108680&mlfb=3RK1301-0AB10-0AA4","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RK1301-0AB10-0AA4/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation is available for this part?","answer":"The part is rated to IEC 60664 and IEC 61131 with pollution degree 3 at 400 V. It carries a 50 kA breaking capacity at 400 V. Specific RoHS, REACH, or UL documentation should be confirmed at time of RFQ, as these are not listed in the available spec fields."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RK1301-0AB10-0AA4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RK1301-0AB10-0AA4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}