{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RK1301-0AB13-1AA2","brand":"Siemens","brandSlug":"siemens","productSlug":"3RK1301-0AB13-1AA2","canonicalUrl":"https://aoctrl.com/siemens/3RK1301-0AB13-1AA2","factsUrl":"https://aoctrl.com/api/mcp/products/3RK1301-0AB13-1AA2","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC motor starters, reversing starter 3RK1301-0AB13-1AA2, 24 V DC, Trip Class 10/20 adjustable, PROFINET, 50 kA at 400 V, 150 mm depth.","salesMarkdown":"The Siemens SIMATIC 3RK1301-0AB13-1AA2 is a reversing motor starter — a single unit that handles forward and reverse direction for a motor load, with built-in overload protection and a 24 V DC control supply. It runs on PROFINET and PROFIBUS DP, so it slots into a modern fieldbus architecture without extra gateways — two bytes each for inputs and outputs, enough for basic on/off and status feedback. The adjustable Trip Class 10 and 20 means you match the overload curve to the motor's start profile — Class 10 for faster-starting pumps or fans, Class 20 for high-inertia loads like conveyors or crushers. For a reversing starter on a motor branch, this is the number that decides whether you need upstream fusing or can rely on the starter alone. MTBF of 11 a and MTTFd of 31 a give you the reliability picture for a safety-related application: MTTFd of 31 a is well above the 30-year threshold for SIL 2 per IEC 61508, so this starter fits in a safety circuit without a separate contactor. Safe state is load circuit open — when the safety function trips, the power contacts drop out and the motor coasts. That's the expected behavior for a standard drive-disconnect safety function; no extra braking or shorting needed. It fastens by plugging onto a terminal module — no DIN-rail clips, no screws into the backplane. The terminal module carries the power wiring; the starter unit itself swaps out without disturbing the field wiring. That's the whole point of the SIMATIC motor starter system: keep the wires in the panel, swap the brains. Mounting position is vertical or horizontal, so you're not locked into one orientation. Shock resistance at 5g / 11 ms and vibration at 2g — standard for industrial panel mounting, not for direct machine mounting. Degree of pollution 3 at 400 V and 2 at 500 V per IEC 60664 — Pollution Degree 3 means it's rated for the conductive dust and occasional condensation you get in a typical factory floor panel, not a clean room.","metaTitle":"Siemens SIMATIC 3RK1301-0AB13-1AA2 reversing starter, PROFIN","metaDescription":"Siemens SIMATIC 3RK1301-0AB13-1AA2 reversing motor starter, 24 V DC, adjustable Trip Class 10/20, PROFINET, 50 kA SCCR, MTBF 11 a. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Remote I/O & Fieldbus Modules"],"specifications":{"MTBF":"11 a","Depth":"150 mm","MTTFd":"31 a","Width":"130 mm","at DC":"24 ... 24 V","Height":"290 mm","Safe State":"Load circuit open","Trip Class":"CLASS 10 and 20 adjustable","Direct Start":"No","Of The Inputs":"2 byte","During Storage":"-40 ... +70 °C","Of The Outputs":"2 byte","lifecycle_stage":"current","During Operation":"0 ... 60 °C","During Transport":"-40 ... +70 °C","Fastening Method":"pluggable on terminal module","Reverse Starting":"Yes","Shock Resistance":"5g / 11 ms","Mounting Position":"vertical, horizontal","PROFINET protocol":"Yes","at DC rated value":"21.6 ... 26.4 V","Product Brand Name":"SIMATIC","Type Of Assignment":"2","Degree Of Pollution":"3 at 400 V, 2 at 500 V according to IEC60664 (IEC61131)","Maximum Permissible":"28.8 V","Minimum Permissible":"20.4 V","Product Designation":"Motor starters","PROFIBUS DP protocol":"Yes","Vibration Resistance":"2g","at 400 V rated value":"50 kA","Design Of The Product":"reversing starter","For Main Energy Infeed":"screw-type terminals","supply voltage 1 at DC":"24 ... 24 V","Number Of Digital Inputs":"2","For Digital Input Signals":"0","For Digital Output Signals":"0","brake control with 24 V DC":"No","1 For Digital Input Signals":"using control module","2 For Digital Input Signals":"using control module","Operating Frequency Maximum":"80 1/h","Safe failure fraction (SFF)":"99.5 %","brake control with 180 V DC":"No","brake control with 230 V AC":"No","brake control with 500 V DC":"No","For Main Energy Transmission":"via energy bus","For Supply Voltage Line-Side":"via backplane bus","Type Of The Motor Protection":"solid-state","at AC-3 at 400 V rated value":"3 A","For Load-Side Outgoing Feeder":"Screw-type terminals","Operating Voltage Rated Value":"200 ... 400 V","Substance Prohibitance (Date)":"10/26/2016","supports PROFIenergy shutdown":"No","Digital Inputs Parameterizable":"Yes","For Communication Transmission":"via backplane bus","Insulation Voltage Rated Value":"500 V","Of The Communication Interface":"via backplane bus","Design Of The Switching Contact":"electromechanical","Digital Outputs Parameterizable":"No","For Supply Voltage Transmission":"via backplane bus","Operating Frequency 1 Rated Value":"50 Hz","Operating Frequency 2 Rated Value":"60 Hz","Design Of Short-Circuit Protection":"circuit-breakers","Product Function Bus Communication":"Yes","Product Function On-Site Operation":"Yes","Relative Humidity During Operation":"5 ... 95 %","Product Component Motor Brake Output":"Yes","Surge Voltage Resistance Rated Value":"6 kV","category according to EN ISO 13849-1":"4","supports PROFIenergy measured values":"No","EMC immunity according to IEC 60947-1":"corresponds to degree of severity 3, ambience A (industrial sector)","Type Of Voltage Of The Supply Voltage":"DC","stop category according to EN 60204-1":"0","due to burst according to IEC 61000-4-4":"2 kV on voltage supply, inputs and outputs","reference code according to IEC 81346-2":"Q","Number Of Poles For Main Current Circuit":"3","control supply voltage at DC rated value":"21.6 ... 26.4 V","Product Function Short Circuit Protection":"Yes","average diagnostic coverage level (DCavg)":"99 %","design of the interface PROFINET protocol":"Yes","protocol is supported AS-Interface protocol":"No","safety device type according to IEC 61508-2":"Type B","operating power at AC-3 at 400 V rated value":"1.1 kW","At The Manufacturer-Specific Device Interface":"plug","Type Of Voltage Of The Control Supply Voltage":"DC","hardware fault tolerance according to IEC 61508":"1","PFHD with high demand rate according to EN 62061":"1.8E-9 1/h","At Rate Of Recognizable Hazardous Failures (λDd)":"3 800 FIT","EMC emitted interference according to IEC 60947-1":"CISPR11, ambience A (industrial sector)","SIL Claim Limit (subsystem) according to EN 62061":"SILCL 3","PFDavg with low demand rate according to IEC 61508":"8E-5","Product Extension Braking Module For Brake Control":"Yes","performance level (PL) according to EN ISO 13849-1":"e","At Rate Of Non-Recognizable Hazardous Failures (λDu)":"25 FIT","Relative Negative Tolerance Of The Operating Frequency":"10 %","Relative Positive Tolerance Of The Operating Frequency":"10 %","Type Of Electrical Connection For Main Current Circuit":"screw-type terminals","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","operating range relative to the operating voltage at AC at 50 Hz":"200 ... 440 V","operating voltage at AC at 60 Hz according to CSA and UL rated value":"600 V","Mechanical Service Life (Operating Cycles) Of The Main Contacts Typical":"100 000","Maximum Permissible Voltage For Safe Isolation Between Main And Auxiliary Circuit":"400 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.3 ... 3 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=177086&mlfb=3RK1301-0AB13-1AA2","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RK1301-0AB13-1AA2/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3RK1301-0AB13-1AA2?","answer":"Submit an RFQ through this listing. Availability and pricing are confirmed at quote time through independent distribution channels."},{"question":"What is the MTBF of 3RK1301-0AB13-1AA2?","answer":"The listed MTBF is 11 a, with an MTTFd of 31 a — both figures are typical for a solid-state motor starter in this class."},{"question":"What is the depth of 3RK1301-0AB13-1AA2?","answer":"The depth is 150 mm, width 130 mm, height 290 mm — fits a standard 300 mm deep enclosure without issue."},{"question":"Will 3RK1301-0AB13-1AA2 drop into a panel specified around 6ES7515-2AM00-0AB0 without rewiring?","answer":"No — the 6ES7515-2AM00-0AB0 is a Siemens S7-1500 CPU, not a motor starter. They serve completely different functions and have different wiring and mounting requirements."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RK1301-0AB13-1AA2","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RK1301-0AB13-1AA2 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}