{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RK1301-0BB13-0AA4","brand":"Siemens","brandSlug":"siemens","productSlug":"3RK1301-0BB13-0AA4","canonicalUrl":"https://aoctrl.com/siemens/3RK1301-0BB13-0AA4","factsUrl":"https://aoctrl.com/api/mcp/products/3RK1301-0BB13-0AA4","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC motor starter, direct starter design, 24 V DC supply, PROFINET and PROFIBUS DP, adjustable trip class 10/20, 50 kA at 400 V, 65 mm width, 150 mm depth, 290 mm height.","salesMarkdown":"## Integrator note — fieldbus slice, safety CPU separation The Siemens SIMATIC 3RK1301-0BB13-0AA4 is a direct starter motor controller built for PROFINET and PROFIBUS DP networks — two protocols on the same module, so it fits existing S7-1500 or ET 200SP islands without a gateway. Supply is 24 V DC (21.6 to 26.4 V rated, 20.4 V min, 28.8 V max). The safe state is load circuit open, which means on loss of communication or power the output drops and the motor stops — no latching. Trip class is adjustable between 10 and 20, so you match the motor's thermal curve in software rather than swapping a heater pack. ## Mounting & integration — checklist cadence Fastening method is pluggable on terminal module — no DIN-rail clip; the base unit snaps onto a separate terminal module that carries the main power wiring. Mounting position is vertical or horizontal. Dimensions: 65 mm wide, 150 mm deep, 290 mm high. Plenty of room for a standard 600 mm deep enclosure. Vibration resistance is 2g; shock resistance 5g / 11 ms. ## Sourcing posture — line-down spare, BOM freeze MTBF is 14 a; MTTFd is 31 a — the safety-related failure rate is better than the basic reliability figure, which is typical for a SIL-rated motor starter. Operating frequency maximum is 80 cycles per hour — not for high-speed indexing; sized for conveyor or pump starts.","metaTitle":"Siemens SIMATIC 3RK1301-0BB13-0AA4 Motor Starter, PROFINET,","metaDescription":"Siemens SIMATIC motor starter 3RK1301-0BB13-0AA4, direct starter with PROFINET/PROFIBUS DP, 24V DC, 50kA at 400V, adjustable trip class 10/20. MTBF 14 a, MTTFd 31 a. Active product","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Remote I/O & Fieldbus Modules"],"specifications":{"MTBF":"14 a","Depth":"150 mm","MTTFd":"31 a","Width":"65 mm","at DC":"24 ... 24 V","title":"3RK1301-0BB13-0AA4","Height":"290 mm","Safe State":"Load circuit open","Trip Class":"CLASS 10 and 20 adjustable","description":"F-DS1E-X for ET 200S Fail-safe DOL starter Setting range 2.4...8 A Mechanical switching Electronic protection AC-3, up to 3 kW / 400 V expandable for Brake control module 2DI module 2DI module Circuit breaker signaling parameterizable","Direct Start":"Yes","Of The Inputs":"2 byte","During Storage":"-40 ... +70 °C","Of The Outputs":"2 byte","lifecycle_stage":"current","During Operation":"0 ... 60 °C","During Transport":"-40 ... +70 °C","Fastening Method":"pluggable on terminal module","Reverse Starting":"No","Shock Resistance":"5g / 11 ms","Mounting Position":"vertical, horizontal","PROFINET protocol":"Yes","at DC rated value":"21.6 ... 26.4 V","Product Brand Name":"SIMATIC","Type Of Assignment":"2","Degree Of Pollution":"3 at 400 V, 2 at 500 V according to IEC60664 (IEC61131)","Maximum Permissible":"28.8 V","Minimum Permissible":"20.4 V","Product Designation":"Motor starters","PROFIBUS DP protocol":"Yes","Vibration Resistance":"2g","at 400 V rated value":"50 kA","Design Of The Product":"direct starter","For Main Energy Infeed":"screw-type terminals","supply voltage 1 at DC":"24 ... 24 V","Number Of Digital Inputs":"2","For Digital Input Signals":"0","For Digital Output Signals":"0","brake control with 24 V DC":"No","1 For Digital Input Signals":"using control module","2 For Digital Input Signals":"using control module","Operating Frequency Maximum":"80 1/h","Safe failure fraction (SFF)":"99.5 %","brake control with 180 V DC":"No","brake control with 230 V AC":"No","brake control with 500 V DC":"No","For Main Energy Transmission":"via energy bus","For Supply Voltage Line-Side":"via backplane bus","Type Of The Motor Protection":"solid-state","at AC-3 at 400 V rated value":"8 A","For Load-Side Outgoing Feeder":"Screw-type terminals","Operating Voltage Rated Value":"200 ... 400 V","Substance Prohibitance (Date)":"10/26/2016","Digital Inputs Parameterizable":"Yes","For Communication Transmission":"via backplane bus","Insulation Voltage Rated Value":"500 V","Of The Communication Interface":"via backplane bus","Design Of The Switching Contact":"electromechanical","Digital Outputs Parameterizable":"No","For Supply Voltage Transmission":"via backplane bus","Operating Frequency 1 Rated Value":"50 Hz","Operating Frequency 2 Rated Value":"60 Hz","Design Of Short-Circuit Protection":"circuit-breakers","Product Function Bus Communication":"Yes","Product Function On-Site Operation":"Yes","Relative Humidity During Operation":"5 ... 95 %","Product Component Motor Brake Output":"Yes","Surge Voltage Resistance Rated Value":"6 kV","category according to EN ISO 13849-1":"4","EMC immunity according to IEC 60947-1":"corresponds to degree of severity 3, ambience A (industrial sector)","Type Of Voltage Of The Supply Voltage":"DC","stop category according to EN 60204-1":"0","due to burst according to IEC 61000-4-4":"2 kV on voltage supply, inputs and outputs","reference code according to IEC 81346-2":"Q","Number Of Poles For Main Current Circuit":"3","control supply voltage at DC rated value":"21.6 ... 26.4 V","Product Function Short Circuit Protection":"Yes","average diagnostic coverage level (DCavg)":"99 %","design of the interface PROFINET protocol":"Yes","protocol is supported AS-Interface protocol":"No","safety device type according to IEC 61508-2":"Type B","operating power at AC-3 at 400 V rated value":"3 kW","At The Manufacturer-Specific Device Interface":"plug","Type Of Voltage Of The Control Supply Voltage":"DC","hardware fault tolerance according to IEC 61508":"1","PFHD with high demand rate according to EN 62061":"1.8E-9 1/h","At Rate Of Recognizable Hazardous Failures (λDd)":"3 800 FIT","EMC emitted interference according to IEC 60947-1":"CISPR11, ambience A (industrial sector)","SIL Claim Limit (subsystem) according to EN 62061":"SILCL 3","PFDavg with low demand rate according to IEC 61508":"8E-5","Product Extension Braking Module For Brake Control":"Yes","performance level (PL) according to EN ISO 13849-1":"e","At Rate Of Non-Recognizable Hazardous Failures (λDu)":"25 FIT","Relative Negative Tolerance Of The Operating Frequency":"10 %","Relative Positive Tolerance Of The Operating Frequency":"10 %","Type Of Electrical Connection For Main Current Circuit":"screw-type terminals","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","operating range relative to the operating voltage at AC at 50 Hz":"200 ... 440 V","operating voltage at AC at 60 Hz according to CSA and UL rated value":"600 V","Mechanical Service Life (Operating Cycles) Of The Main Contacts Typical":"100 000","Maximum Permissible Voltage For Safe Isolation Between Main And Auxiliary Circuit":"400 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"2.4 ... 8 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e8603ecc0bf84faa55be3b575ad82ec0.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=277926&mlfb=3RK1301-0BB13-0AA4"},"ai":{"faq":[{"question":"What is the MTBF of 3RK1301-0BB13-0AA4?","answer":"MTBF is 14 a; MTTFd is 31 a — the safety-related mean time to dangerous failure is higher than the basic reliability figure."},{"question":"Where can I buy 3RK1301-0BB13-0AA4?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time."},{"question":"What is the supply voltage for 3RK1301-0BB13-0AA4?","answer":"Rated 24 V DC (24 V nominal), operating range 21.6 to 26.4 V, min 20.4 V, max 28.8 V."},{"question":"What trip classes does 3RK1301-0BB13-0AA4 support?","answer":"Adjustable trip class 10 and 20 — selectable via parameterization to match the motor thermal curve."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RK1301-0BB13-0AA4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RK1301-0BB13-0AA4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}