{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RK1301-0BB13-1AA4","brand":"Siemens","brandSlug":"siemens","productSlug":"3RK1301-0BB13-1AA4","canonicalUrl":"https://aoctrl.com/siemens/3RK1301-0BB13-1AA4","factsUrl":"https://aoctrl.com/api/mcp/products/3RK1301-0BB13-1AA4","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC motor starter, reversing starter, 3RK1301-0BB13-1AA4, PROFINET, PROFIBUS DP, 50 kA at 400 V, adjustable trip Class 10/20, 24 V DC control, pluggable on terminal module.","salesMarkdown":"The adjustable trip Class 10/20 lets you tune the overload curve to the motor's acceleration profile: Class 10 for standard induction motors, Class 20 for longer ramp times. MTTFd of 31 a and MTBF of 11 a are reliability figures for the safety function — the 31 a MTTFd aligns with SIL 2 / PL d requirements per IEC 61508, so this starter can serve in a safety circuit guarding a hazard zone. This reversing starter mounts by plugging onto a terminal module, not direct DIN-rail snap-on — the terminal module is the base that carries the power wiring, and the starter module clicks onto it. That means the panel layout needs space for the terminal module footprint first. Dimensions are 130 mm wide, 290 mm high, 150 mm deep. Mounting position is vertical or horizontal, giving flexibility in tight enclosures. The 24 V DC control supply has a rated range of 21.6 to 26.4 V DC, with absolute limits of 20.4 V minimum and 28.8 V maximum — stay inside those for reliable pick-up and dropout. Shock resistance is 5 g for 11 ms, vibration resistance 2 g — adequate for most industrial machinery but not for high-shock applications like stamping presses without additional isolation. Pollution degree 3 at 400 V, degree 2 at 500 V per IEC 60664 / IEC 61131 — this matters for creepage and clearance distances in dirty or humid environments.","metaTitle":"Siemens 3RK1301-0BB13-1AA4 SIMATIC Reversing Motor Starter,","metaDescription":"Siemens SIMATIC 3RK1301-0BB13-1AA4 reversing motor starter. PROFINET/PROFIBUS DP, adjustable Class 10/20, 50 kA at 400 V, MTTFd 31 a. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Remote I/O & Fieldbus Modules"],"specifications":{"MTBF":"11 a","Depth":"150 mm","MTTFd":"31 a","Width":"130 mm","at DC":"24 ... 24 V","Height":"290 mm","Safe State":"Load circuit open","Trip Class":"CLASS 10 and 20 adjustable","Direct Start":"No","Of The Inputs":"2 byte","During Storage":"-40 ... +70 °C","Of The Outputs":"2 byte","lifecycle_stage":"current","During Operation":"0 ... 60 °C","During Transport":"-40 ... +70 °C","Fastening Method":"pluggable on terminal module","Reverse Starting":"Yes","Shock Resistance":"5g / 11 ms","Mounting Position":"vertical, horizontal","PROFINET protocol":"Yes","at DC rated value":"21.6 ... 26.4 V","Product Brand Name":"SIMATIC","Type Of Assignment":"2","Degree Of Pollution":"3 at 400 V, 2 at 500 V according to IEC60664 (IEC61131)","Maximum Permissible":"28.8 V","Minimum Permissible":"20.4 V","Product Designation":"Motor starters","PROFIBUS DP protocol":"Yes","Vibration Resistance":"2g","at 400 V rated value":"50 kA","Design Of The Product":"reversing starter","For Main Energy Infeed":"screw-type terminals","supply voltage 1 at DC":"24 ... 24 V","Number Of Digital Inputs":"2","For Digital Input Signals":"0","For Digital Output Signals":"0","brake control with 24 V DC":"No","1 For Digital Input Signals":"using control module","2 For Digital Input Signals":"using control module","Operating Frequency Maximum":"80 1/h","Safe failure fraction (SFF)":"99.5 %","brake control with 180 V DC":"No","brake control with 230 V AC":"No","brake control with 500 V DC":"No","For Main Energy Transmission":"via energy bus","For Supply Voltage Line-Side":"via backplane bus","Type Of The Motor Protection":"solid-state","at AC-3 at 400 V rated value":"8 A","For Load-Side Outgoing Feeder":"Screw-type terminals","Operating Voltage Rated Value":"200 ... 400 V","Substance Prohibitance (Date)":"10/26/2016","Digital Inputs Parameterizable":"Yes","For Communication Transmission":"via backplane bus","Insulation Voltage Rated Value":"500 V","Of The Communication Interface":"via backplane bus","Design Of The Switching Contact":"electromechanical","Digital Outputs Parameterizable":"No","For Supply Voltage Transmission":"via backplane bus","Operating Frequency 1 Rated Value":"50 Hz","Operating Frequency 2 Rated Value":"60 Hz","Design Of Short-Circuit Protection":"circuit-breakers","Product Function Bus Communication":"Yes","Product Function On-Site Operation":"Yes","Relative Humidity During Operation":"5 ... 95 %","Product Component Motor Brake Output":"Yes","Surge Voltage Resistance Rated Value":"6 kV","category according to EN ISO 13849-1":"4","EMC immunity according to IEC 60947-1":"corresponds to degree of severity 3, ambience A (industrial sector)","Type Of Voltage Of The Supply Voltage":"DC","stop category according to EN 60204-1":"0","due to burst according to IEC 61000-4-4":"2 kV on voltage supply, inputs and outputs","reference code according to IEC 81346-2":"Q","Number Of Poles For Main Current Circuit":"3","control supply voltage at DC rated value":"21.6 ... 26.4 V","Product Function Short Circuit Protection":"Yes","average diagnostic coverage level (DCavg)":"99 %","design of the interface PROFINET protocol":"Yes","protocol is supported AS-Interface protocol":"No","safety device type according to IEC 61508-2":"Type B","operating power at AC-3 at 400 V rated value":"3 kW","At The Manufacturer-Specific Device Interface":"plug","Type Of Voltage Of The Control Supply Voltage":"DC","hardware fault tolerance according to IEC 61508":"1","PFHD with high demand rate according to EN 62061":"1.8E-9 1/h","At Rate Of Recognizable Hazardous Failures (λDd)":"3 800 FIT","EMC emitted interference according to IEC 60947-1":"CISPR11, ambience A (industrial sector)","SIL Claim Limit (subsystem) according to EN 62061":"SILCL 3","PFDavg with low demand rate according to IEC 61508":"8E-5","Product Extension Braking Module For Brake Control":"Yes","performance level (PL) according to EN ISO 13849-1":"e","At Rate Of Non-Recognizable Hazardous Failures (λDu)":"25 FIT","Relative Negative Tolerance Of The Operating Frequency":"10 %","Relative Positive Tolerance Of The Operating Frequency":"10 %","Type Of Electrical Connection For Main Current Circuit":"screw-type terminals","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","operating range relative to the operating voltage at AC at 50 Hz":"200 ... 440 V","operating voltage at AC at 60 Hz according to CSA and UL rated value":"600 V","Mechanical Service Life (Operating Cycles) Of The Main Contacts Typical":"100 000","Maximum Permissible Voltage For Safe Isolation Between Main And Auxiliary Circuit":"400 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"2.4 ... 8 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,038.86","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=403654&mlfb=3RK1301-0BB13-1AA4","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RK1301-0BB13-1AA4/alternatives.json"},"ai":{"faq":[{"question":"What is the MTTFd and MTBF for this motor starter?","answer":"MTTFd is 31 a and MTBF is 11 a. The 31 a MTTFd supports SIL 2 / PL d safety function requirements."},{"question":"What network protocols does 3RK1301-0BB13-1AA4 support?","answer":"It supports both PROFINET and PROFIBUS DP protocols, giving flexibility for integration into Siemens or third-party automation architectures."},{"question":"Where can I buy 3RK1301-0BB13-1AA4 and how is it quoted?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the short-circuit rating of this reversing starter?","answer":"Rated short-circuit current is 50 kA at 400 V, meaning it can be placed on a supply with fault current up to that level without an upstream current-limiting device."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RK1301-0BB13-1AA4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RK1301-0BB13-1AA4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}