{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RK1301-0FB00-0AA2","brand":"Siemens","brandSlug":"siemens","productSlug":"3RK1301-0FB00-0AA2","canonicalUrl":"https://aoctrl.com/siemens/3RK1301-0FB00-0AA2","factsUrl":"https://aoctrl.com/api/mcp/products/3RK1301-0FB00-0AA2","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC motor starter, direct starter, 3RK1301-0FB00-0AA2, 24 V DC, CLASS 10, 50 kA at 400 V, PROFINET/PROFIBUS DP.","salesMarkdown":"## SIMATIC direct starter — 3RK1301-0FB00-0AA2 The Siemens 3RK1301-0FB00-0AA2 is a SIMATIC direct starter motor starter, designed for direct-on-line starting of three-phase motors. The unit is pluggable on a terminal module, so it swaps without disturbing the power wiring. Rated 50 kA at 400 V — that is the short-circuit breaking capacity at the main incoming supply level. For a panel fed from a 400 V transformer with an SCCR requirement above 50 kA, this starter coordinates cleanly without needing upstream fuses to clip the fault current. The 24 V DC control supply (20.4 to 28.8 V range) is standard for modern PLC cabinets; the unit pulls its logic power from the same 24 V bus as the rest of the SIMATIC I/O. Operating frequency is rated at a maximum of 750 1/h — that is about one start every 4.8 seconds. Fine for most conveyor and fan duty; not suited for high-cycle indexing or rapid reversing (reverse starting is explicitly not supported). Mounting is vertical or horizontal, and the 45 mm width and 120 mm depth fit standard 45 mm DIN-rail spacing. ## Network integration — PROFINET and PROFIBUS DP This starter supports both PROFINET and PROFIBUS DP protocols natively. The digital I/O map is 1 byte input and 1 byte output — enough for start/stop feedback, fault status, and a few diagnostic bits. No additional gateway or communication module is needed; it connects directly to the PLC via the network cable. Shock resistance is 5 g for 11 ms, vibration resistance 2 g — suitable for panel mounting in industrial environments with moderate vibration. Degree of pollution is 3 at 400 V and 2 at 500 V per IEC 60664, which covers most factory floor conditions (conductive dust, occasional condensation).","metaTitle":"Siemens 3RK1301-0FB00-0AA2 SIMATIC Motor Starter, CLASS 10,","metaDescription":"Siemens 3RK1301-0FB00-0AA2 SIMATIC motor starter, direct start, CLASS 10, 50 kA at 400 V, 24 V DC, PROFINET/PROFIBUS DP. Current lifecycle. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Remote I/O & Fieldbus Modules"],"specifications":{"Depth":"120 mm","Width":"45 mm","at DC":"24 ... 24 V","title":"3RK1301-0FB00-0AA2","Height":"265 mm","Trip Class":"CLASS 10","description":"DS1-X for ET 200S Standard DOL starter expandable Setting range 0.35...0.5 A AC-3, 0.12 kW / 400 V Electromechanical starter for brake control module","Direct Start":"Yes","Of The Inputs":"1 byte","During Storage":"-40 ... +70 °C","Of The Outputs":"1 byte","lifecycle_stage":"current","During Operation":"0 ... 60 °C","During Transport":"-40 ... +70 °C","Fastening Method":"pluggable on terminal module","Reverse Starting":"No","Shock Resistance":"5g / 11 ms","Mounting Position":"vertical, horizontal","PROFINET protocol":"Yes","at DC rated value":"20.4 ... 28.8 V","Product Brand Name":"SIMATIC","Type Of Assignment":"2","Degree Of Pollution":"3 at 400 V, 2 at 500 V according to IEC60664 (IEC61131)","Maximum Permissible":"28.8 V","Minimum Permissible":"20.4 V","Product Designation":"Motor starters","With Bypass Circuit":"4.1184 W","PROFIBUS DP protocol":"Yes","Vibration Resistance":"2g","at 400 V rated value":"50 kA","Design Of The Product":"direct starter","For Main Energy Infeed":"screw-type terminals","Without Bypass Circuit":"4.118 W","supply voltage 1 at DC":"24 ... 24 V","Number Of Digital Inputs":"0","For Digital Input Signals":"0","For Digital Output Signals":"0","brake control with 24 V DC":"No","1 For Digital Input Signals":"using control module","2 For Digital Input Signals":"using control module","Operating Frequency Maximum":"750 1/h","brake control with 180 V DC":"No","brake control with 230 V AC":"No","brake control with 500 V DC":"No","For Main Energy Transmission":"via energy bus","For Supply Voltage Line-Side":"via backplane bus","Type Of The Motor Protection":"bimetal","at AC-3 at 400 V rated value":"0.5 A","For Load-Side Outgoing Feeder":"Screw-type terminals","Operating Voltage Rated Value":"200 ... 400 V","Substance Prohibitance (Date)":"10/26/2016","supports PROFIenergy shutdown":"No","Digital Inputs Parameterizable":"No","For Communication Transmission":"via backplane bus","Insulation Voltage Rated Value":"500 V","Of The Communication Interface":"via backplane bus","Design Of The Switching Contact":"electromechanical","Digital Outputs Parameterizable":"No","For Supply Voltage Transmission":"via backplane bus","Operating Frequency 1 Rated Value":"50 Hz","Operating Frequency 2 Rated Value":"60 Hz","Design Of Short-Circuit Protection":"circuit-breakers","Product Function Bus Communication":"Yes","Product Function On-Site Operation":"Yes","Relative Humidity During Operation":"5 ... 95 %","Product Component Motor Brake Output":"Yes","Surge Voltage Resistance Rated Value":"6 kV","supports PROFIenergy measured values":"No","EMC immunity according to IEC 60947-1":"corresponds to degree of severity 3, ambience A (industrial sector)","Type Of Voltage Of The Supply Voltage":"DC","due to burst according to IEC 61000-4-4":"2 kV on voltage supply, inputs and outputs","reference code according to IEC 81346-2":"Q","Number Of Poles For Main Current Circuit":"3","control supply voltage at DC rated value":"20.4 ... 28.8 V","Product Function Short Circuit Protection":"Yes","design of the interface PROFINET protocol":"Yes","with low demand rate according to SN 31920":"100 FIT","protocol is supported AS-Interface protocol":"No","with high demand rate according to SN 31920":"75 %","operating power at AC-3 at 400 V rated value":"0.12 kW","At The Manufacturer-Specific Device Interface":"plug","Type Of Voltage Of The Control Supply Voltage":"DC","EMC emitted interference according to IEC 60947-1":"CISPR11, ambience A (industrial sector)","Product Extension Braking Module For Brake Control":"Yes","Relative Negative Tolerance Of The Operating Frequency":"10 %","Relative Positive Tolerance Of The Operating Frequency":"10 %","Type Of Electrical Connection For Main Current Circuit":"screw-type terminals","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","operating range relative to the operating voltage at AC at 50 Hz":"200 ... 440 V","operating voltage at AC at 60 Hz according to CSA and UL rated value":"600 V","Mechanical Service Life (Switching Cycles) Of The Main Contacts Typical":"100 000","power loss [W] for rated value of the current without load current share typical":"4.12 W","Maximum Permissible Voltage For Safe Isolation Between Main And Auxiliary Circuit":"400 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.35 ... 0.5 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$411.48","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1f364642fd5f31cab1654dcf6dd146b4.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=162336&mlfb=3RK1301-0FB00-0AA2"},"ai":{"faq":[{"question":"What is the short-circuit breaking capacity of 3RK1301-0FB00-0AA2?","answer":"Rated 50 kA at 400 V. This is the maximum fault current the starter can safely interrupt at that voltage level."},{"question":"What network protocols does this motor starter support?","answer":"It supports both PROFINET and PROFIBUS DP natively, with a 1-byte input and 1-byte output data map."},{"question":"What is the control voltage for 3RK1301-0FB00-0AA2?","answer":"24 V DC nominal, with an operating range of 20.4 to 28.8 V DC."},{"question":"How do I get pricing and availability for 3RK1301-0FB00-0AA2?","answer":"This part is sourced and quoted to order against an RFQ. Submit a request for current pricing and availability, which is confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RK1301-0FB00-0AA2","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RK1301-0FB00-0AA2 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}