{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RK1304-0HS00-8AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RK1304-0HS00-8AA0","canonicalUrl":"https://aoctrl.com/siemens/3RK1304-0HS00-8AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3RK1304-0HS00-8AA0","rawCanonicalId":null},"summary":{"shortDescription":"ET 200pro ASm 400 V Disconnection module 400 V to 25 A for safe switching-off up to Category 3/4 Han Q4/2","salesMarkdown":null,"metaTitle":"3RK1304-0HS00-8AA0 - Siemens","metaDescription":"ET 200pro ASm 400 V Disconnection module 400 V to 25 A for safe switching-off up to Category 3/4 Han Q4/2","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Remote I/O & Fieldbus Modules"],"specifications":{"Depth":"150 mm","MTTFd":"100 a","Width":"110 mm","at DC":"24 ... 24 V","Height":"230 mm","Safe State":"Load circuit open","Of The Inputs":"1 byte","During Storage":"-40 ... +70 °C","Of The Outputs":"0 byte","Type Of Voltage":"AC","lifecycle_stage":"current","During Operation":"-25 ... +55 °C","During Transport":"-40 ... +70 °C","Fastening Method":"screw fixing","Shock Resistance":"15g / 11 ms","Mounting Position":"any","PROFINET protocol":"Yes","at DC rated value":"20.4 ... 28.8 V","Product Brand Name":"SIMATIC","Type Of Assignment":"1","Degree Of Pollution":"3","Maximum Permissible":"28.8 V","Minimum Permissible":"20.4 V","Product Designation":"Motor starters","protection class IP":"IP65","PROFIBUS DP protocol":"Yes","Vibration Resistance":"2g","Design Of The Product":"safety disconnecting module","For Main Energy Infeed":"socket according to ISO23570","supply voltage 1 at DC":"24 ... 24 V","Number Of Digital Inputs":"0","For Digital Input Signals":"0","For Digital Output Signals":"0","at AC at 400 V rated value":"25 A","brake control with 24 V DC":"No","1 For Digital Input Signals":"M12 socket","2 For Digital Input Signals":"M12 socket","3 For Digital Input Signals":"M12 socket","4 For Digital Input Signals":"M12 socket","Safe failure fraction (SFF)":"99 %","brake control with 180 V DC":"No","brake control with 230 V AC":"No","brake control with 400 V AC":"No","brake control with 500 V DC":"No","For Main Energy Transmission":"socket according to ISO23570","For Supply Voltage Line-Side":"via backplane bus","at AC-3 at 400 V rated value":"25 A","For Load-Side Outgoing Feeder":"socket according to ISO23570","Operating Voltage Rated Value":"200 ... 400 V","Substance Prohibitance (Date)":"05/28/2009","supports PROFIenergy shutdown":"No","Digital Inputs Parameterizable":"No","Insulation Voltage Rated Value":"400 V","Design Of The Switching Contact":"electromechanical","Digital Outputs Parameterizable":"No","For Supply Voltage Transmission":"via backplane bus","Product Function Bus Communication":"Yes","Product Function On-Site Operation":"No","Relative Humidity During Operation":"5 ... 95 %","Product Component Motor Brake Output":"No","Surge Voltage Resistance Rated Value":"6 kV","category according to EN ISO 13849-1":"4","supports PROFIenergy measured values":"No","Type Of Voltage Of The Supply Voltage":"DC","stop category according to EN 60204-1":"0","reference code according to IEC 81346-2":"Q","Number Of Poles For Main Current Circuit":"3","control supply voltage at DC rated value":"20.4 ... 28.8 V","Product Function Short Circuit Protection":"No","Touch Protection Against Electrical Shock":"finger-safe","average diagnostic coverage level (DCavg)":"99 %","design of the interface PROFINET protocol":"Yes","protocol is supported AS-Interface protocol":"No","safety device type according to IEC 61508-2":"Type A","At The Manufacturer-Specific Device Interface":"optical interface","Type Of Voltage Of The Control Supply Voltage":"DC","hardware fault tolerance according to IEC 61508":"1","PFHD with high demand rate according to EN 62061":"5.35E-11 1/h","SIL Claim Limit (subsystem) according to EN 62061":"SILCL 3","performance level (PL) according to EN ISO 13849-1":"e","Type Of Electrical Connection For Main Current Circuit":"tab terminals","Installation Altitude At Height Above Sea Level Maximum":"3 500 m","Type Of Electrical Connection Of The Communication Interface":"via backplane bus","operating range relative to the operating voltage at AC at 50 Hz":"200 ... 440 V","operating voltage at AC at 60 Hz according to CSA and UL rated value":"600 V","Maximum Permissible Voltage For Safe Isolation Between Main And Auxiliary Circuit":"400 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"25 ... 25 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=93831&mlfb=3RK1304-0HS00-8AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RK1304-0HS00-8AA0/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RK1304-0HS00-8AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RK1304-0HS00-8AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}