{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RK1305-0AS01-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RK1305-0AS01-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3RK1305-0AS01-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3RK1305-0AS01-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3RK1305-0AS01-0AA0 — now in phase-out and being discontinued. Supplied from remaining channel stock; full specifications, lifecycle and same-series options are below.","salesMarkdown":"## Overview The 3RK1305-0AS01-0AA0 is a Siemens SIRIUS M200D communication module for PROFIBUS DP, designed to connect M200D motor starters to a PROFIBUS DP fieldbus network. It carries two M12 bus connectors with loop-through, two 7/8\" power connectors for 24 V DC supply with loop-through, and an integrated bus terminating resistor that can be activated via a technology module 3RK1395. Rated IP65 with screw fixing, the module is built for distributed installation directly on the machine frame, and is officially classified as phase-out by Siemens with discontinuation scheduled for 2025-08-01. This module acts as the PROFIBUS DP interface for a SIRIUS M200D motor starter cluster. The two M12 bus connectors allow a daisy-chain loop-through topology, simplifying cabling on long machine lines. The integrated bus terminating resistor, enabled through the optional 3RK1395 technology module, eliminates the need for a separate terminator at the end of the segment. Power is supplied at 24 V DC via two 7/8\" connectors with loop-through, maintaining a single power feed for multiple starters. The module's shock rating of 12 g / 11 ms reflects its suitability for high-vibration environments such as conveyor systems and packaging machinery. ## Applications The M200D communication module is used in distributed motor control applications where individual motor starters are mounted near the driven equipment rather than in a central cabinet. Typical installations include automotive assembly lines, material handling systems, and packaging machines where PROFIBUS DP is the chosen fieldbus. Siemens has classified the 3RK1305-0AS01-0AA0 as phase-out, with a formal discontinuation date of 2025-08-01. After this date, the module will no longer be manufactured or available through standard Siemens channels. Buyers with active BOMs or installed bases should evaluate last-time-buy quantities or identify a migration path to a current communication interface, such as a PROFINET variant in the M200D family.","metaTitle":"Siemens 3RK1305-0AS01-0AA0 M200D PROFIBUS Communication Module","metaDescription":"Siemens 3RK1305-0AS01-0AA0 SIRIUS M200D communication module for PROFIBUS DP, 24 V DC, IP65, 12g shock, phase-out 2025-08-01.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"NRND","categoryPath":["Remote I/O & Fieldbus Modules"],"specifications":{"Depth":"32mm","Width":"174mm","Height":"139mm","During Storage":"-40 ... +70°C","lifecycle_stage":"current","During Operation":"-25 ... +55°C","During Transport":"-40 ... +70°C","Fastening Method":"screw fixing","Shock Resistance":"12g / 11 ms","Mounting Position":"vertical, horizontal, flat","at DC rated value":"24V","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"Communication module","protection class IP":"IP65","Vibration Resistance":"7 mm / 2g","Design Of The Product":"communication module","Mounting Position Recommended":"horizontal","For Communication Transmission":"M12 socket","Insulation Voltage Rated Value":"30V","For Auxiliary And Control Circuit":"connector","Product Function Bus Communication":"Yes","Relative Humidity During Operation":"10 ... 95%","Surge Voltage Resistance Rated Value":"800V","EMC immunity according to IEC 60947-1":"corresponds to degree of severity 3, ambience A (industrial sector)","Type Of Voltage Of The Supply Voltage":"DC","at DC rated value maximum permissible":"28.8V","at DC rated value minimum permissible":"20.4V","control circuit interface with IO link":"No","reference code according to EN 61346-2":"Q","protocol is supported PROFINET protocol":"No","protocol is supported PROFIBUS DP protocol":"Yes","protocol is supported AS-Interface protocol":"No","Control Circuit Interface To Parallel Wiring":"No","design of the interface PROFIBUS DP protocol":"Yes","Type Of Voltage Of The Control Supply Voltage":"DC","design of the interface AS-Interface protocol":"No","EMC emitted interference according to IEC 60947-1":"CISPR11, ambience A (industrial sector)","Installation Altitude At Height Above Sea Level Maximum":"2 000m","Type Of Electrical Connection Of The Communication Interface":"M12 plug"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$148.59","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5cfb9f90fc532611ddd44c2a64801c0c.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=245387&mlfb=3RK1305-0AS01-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RK1305-0AS01-0AA0/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RK1305-0AS01-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RK1305-0AS01-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}