{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RK1308-0DE00-0CP0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RK1308-0DE00-0CP0","canonicalUrl":"https://aoctrl.com/siemens/3RK1308-0DE00-0CP0","factsUrl":"https://aoctrl.com/api/mcp/products/3RK1308-0DE00-0CP0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC 3RK1308-0DE00-0CP0, fail-safe reversing starter, 4 via 3DI/LC module, PROFINET and PROFIBUS DP, adjustable trip class OFF/5/10, B10d 910,000, 24 V DC supply, 150 x 30 x 142 mm.","salesMarkdown":"## Fail-safe reversing starter with integrated safety logic The Siemens 3RK1308-0DE00-0CP0 is a SIMATIC fail-safe reversing starter that integrates a 4 via 3DI/LC module — four safe digital inputs and a load circuit monitoring channel — into a single 30 mm-wide housing that plugs onto a base unit. It handles reversing motor control with integrated safety functions, so you can wire a Category 3 / PL d safety circuit without a separate safety relay. The B10d value of 910,000 cycles gives a mean time to dangerous failure you can plug into your SIL calculation per IEC 62061. Supply is 24 V DC nominal, with a permissible range of 20.4 V to 28.8 V. The trip class is adjustable to OFF (instantaneous), 5, or 10, matching the motor thermal characteristic. Minimum load is 50 % of the smallest adjustable rated current — so if you set the overload to 1 A, the starter needs at least 0.5 A load current to trip correctly. ## PROFINET and PROFIBUS DP onboard Both PROFINET and PROFIBUS DP protocols are supported natively. The module maps 4 bytes of input data and 2 bytes of output data onto the fieldbus, so the PLC sees the starter's status and can command start, stop, and direction without hardwired control wires. ON-delay is 35 ms; OFF-delay ranges from 35 to 50 ms, which matters when coordinating with downstream contactors in a reversing pair. Mounting position is vertical or horizontal with derating observed per the manual. The pluggable base unit lets you pre-wire the power and PROFINET/PROFIBUS drop cables, then snap the electronics module on during commissioning — saves panel space and wiring time on a multi-starter line. Operating temperature is -25 °C to +60 °C with derating above 40 °C per the manual; storage and transport range is -40 °C to +70 °C. Shock resistance is 6 g for 11 ms; vibration resistance is 15 mm amplitude up to 6 Hz and 2 g up to 500 Hz. Dimensions are 150 mm depth, 30 mm width, 142 mm height. The 30 mm width fits standard DIN-rail spacing; a row of four starters occupies 120 mm of rail. Clearance above and below is 50 mm each for airflow and cable bending radius.","metaTitle":"Siemens 3RK1308-0DE00-0CP0 SIMATIC Fail-Safe Reversing Start","metaDescription":"Siemens 3RK1308-0DE00-0CP0 fail-safe reversing starter, 4 via 3DI/LC module, PROFINET/PROFIBUS DP, adjustable trip class, B10d 910,000. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"150 mm","Width":"30 mm","Height":"142 mm","Mounting":"pluggable in BaseUnit","Trip Class":"CLASS OFF / 5 / 10 adjustable","Product Status":"Active"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$350.52","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f48af3065e83d9d1d0e3797e4e1a6512.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=805682&mlfb=3RK1308-0DE00-0CP0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RK1308-0DE00-0CP0/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RK1308-0DE00-0CP0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RK1308-0DE00-0CP0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}