{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RK1315-6KS71-2AA3","brand":"Siemens","brandSlug":"siemens","productSlug":"3RK1315-6KS71-2AA3","canonicalUrl":"https://aoctrl.com/siemens/3RK1315-6KS71-2AA3","factsUrl":"https://aoctrl.com/api/mcp/products/3RK1315-6KS71-2AA3","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS direct starter, 3RK1315-6KS71-2AA3, CLASS 10, IP65, 24 V DC, AS-Interface, 4 digital inputs, 1 digital output.","salesMarkdown":"The Siemens SIRIUS 3RK1315-6KS71-2AA3 is a direct motor starter — a self-contained unit that combines a contactor and overload relay in one IP65 housing, designed for starting and protecting three-phase motors up to 0.75 kW at 400 V or 0.7 hp at 460/480 V. ## Integration and connectivity Communication runs over AS-Interface, a two-wire bus that carries both power and data to the starter — no separate control cable needed for the coil. Device addressing is done via an M12 plug on the unit. The main power circuit connects through a HAN Q4/2 plug conforming to ISO 23570, so the power cable is a factory-made harness, not field-wired into the housing. Four digital inputs and one digital output are available for local sensors or actuators. Supply voltage is 24 V DC nominal, with a permissible range of 20.4 to 28.8 V. The unit accepts screw fixing and can be mounted vertically, horizontally, or flat — the recommended orientation is horizontal for optimal heat dissipation. Panel space should be checked against these dimensions before committing the cutout. The unit withstands vibration of 7 mm / 2g and shock of 12g for 11 ms, making it suitable for mounting on machinery that sees moderate mechanical stress. The ON-delay is 25 ms and the OFF-delay is 35 ms — these are fixed, not adjustable, so sequence timing in the PLC program must account for them if the starter is used in a fast interlock chain.","metaTitle":"Siemens 3RK1315-6KS71-2AA3 SIRIUS Direct Starter, CLASS 10,","metaDescription":"Siemens SIRIUS 3RK1315-6KS71-2AA3 direct motor starter. CLASS 10 trip, IP65 enclosure, AS-Interface, 4 DI / 1 DO. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"NRND","categoryPath":["Remote I/O & Fieldbus Modules"],"specifications":{"Depth":"159 mm","Width":"294 mm","at DC":"20.4 ... 28.8 V","title":"3RK1315-6KS71-2AA3","Height":"215 mm","Trip Class":"CLASS 10","Recommended":"horizontal","description":"SIRIUS motor starter M200D AS-i Communication: AS-Interface DOL starter Basic Electronic switching AC-3, 0.75KW / 400 V 0.15 A...2.00 A Electronic overload protection Thermistor: THERMOCLICK / PTC with brake contact 400 V AC 2DI AS-i + 2DI / 1DO on device Han Q4/2 - Han Q8/0 with manual on-site operation and key-operated switch","Direct Start":"Yes","ON-delay time":"25 ms","During Storage":"-40 ... +70 °C","OFF-delay time":"35 ms","lifecycle_stage":"current","During Operation":"-25 ... +55 °C","During Transport":"-40 ... +70 °C","Fastening Method":"screw fixing","Reverse Starting":"No","Shock Resistance":"12g / 11 ms","Mounting Position":"vertical, horizontal, flat","On-Site Operation":"Yes","PROFINET protocol":"No","at DC rated value":"20.4 ... 28.8 V","Product Brand Name":"SIRIUS","Type Of Assignment":"1","Degree Of Pollution":"3","Maximum Permissible":"31.6 V","Minimum Permissible":"26.5 V","Product Designation":"Motor starters","protection class IP":"IP65","PROFIBUS DP protocol":"No","Vibration Resistance":"7 mm / 2g","at 400 V rated value":"0.75 kW","at 500 V rated value":"750 W","AS-Interface protocol":"Yes","Design Of The Product":"direct starter","For Device Addressing":"M12 plug","supply voltage 1 at DC":"24 V","For Main Current Circuit":"plug according to ISO 23570, HAN Q4/2","Number Of Digital Inputs":"4","at 460/480 V rated value":"0.7 hp","For Digital Input Signals":"4","Number Of Digital Outputs":"1","For Digital Output Signals":"1","at AC at 400 V rated value":"2 A","brake control with 24 V DC":"No","1 For Digital Input Signals":"M12 socket","2 For Digital Input Signals":"M12 socket","3 For Digital Input Signals":"M12 socket","4 For Digital Input Signals":"M12 socket","brake control with 180 V DC":"No","brake control with 230 V AC":"Yes","brake control with 400 V AC":"Yes","brake control with 500 V DC":"No","1 For Digital Output Signals":"M12 socket","For Supply Voltage Line-Side":"M12 plug","In Standby Mode Of Operation":"100 mA","Type Of The Motor Protection":"full motor protection","at AC-3 at 400 V rated value":"2 A","Operating Voltage Rated Value":"200 ... 440 V","Substance Prohibitance (Date)":"07/01/2006","Digital Inputs Parameterizable":"No","Insulation Voltage Rated Value":"500 V","Design Of The Switching Contact":"solid-state / thyristor / 2 phases","Digital Outputs Parameterizable":"No","For Auxiliary And Control Circuit":"connector","Between Main And Auxiliary Circuit":"400 V","Design Of Short-Circuit Protection":"circuit-breakers","Product Function Bus Communication":"Yes","Relative Humidity During Operation":"10 ... 95 %","supply voltage 1 at DC rated value":"30 V","Product Component Motor Brake Output":"Yes","Surge Voltage Resistance Rated Value":"6 000 V","Between Control And Auxiliary Circuit":"24 V","EMC immunity according to IEC 60947-1":"corresponds to degree of severity 3, ambience A (industrial sector)","Type Of Voltage Of The Supply Voltage":"DC","due to burst according to IEC 61000-4-4":"2 kV network connection / 1 kV control connection","Number Of Poles For Main Current Circuit":"3","control supply voltage at DC rated value":"20.4 ... 28.8 V","Product Function Short Circuit Protection":"Yes","Touch Protection Against Electrical Shock":"finger-safe","in switching state ON with bypass circuit":"2.1888 W","in switching state OFF with bypass circuit":"1.9584 W","protocol is supported AS-Interface protocol":"Yes","Control Circuit Interface To Parallel Wiring":"No","At The Manufacturer-Specific Device Interface":"optical interface","Type Of Voltage Of The Control Supply Voltage":"DC","EMC emitted interference according to IEC 60947-1":"CISPR11, ambience A (group 2)","Product Extension Braking Module For Brake Control":"No","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","product function control circuit interface with IO link":"No","Type Of Electrical Connection Of The Communication Interface":"M12 plug","full-load current (FLA) for 3-phase AC motor at 480 V rated value":"1.6 A","operating voltage at AC at 60 Hz according to CSA and UL rated value":"480 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.15 ... 2 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/fdce8980fcf77f7d2cb46c9b2ab02a66.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=115231&mlfb=3RK1315-6KS71-2AA3"},"ai":{"faq":[{"question":"What compliance documentation does Siemens provide for 3RK1315-6KS71-2AA3?","answer":"As a SIRIUS product, it carries CE marking for the European market and is designed to meet relevant IEC/EN standards for motor starters. Specific declarations (RoHS, REACH, UL) are available from Siemens on request."},{"question":"What are the key dimensions of 3RK1315-6KS71-2AA3?","answer":"Width 294 mm, height 215 mm, depth 159 mm. Mounting is by screw fixing in any orientation (vertical, horizontal, flat), with horizontal recommended."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RK1315-6KS71-2AA3","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RK1315-6KS71-2AA3 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-20T14:41:02.429Z","lastPublished":"2026-07-20T14:41:02.429Z","indexable":true}}