{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RK1315-6NS71-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RK1315-6NS71-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3RK1315-6NS71-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3RK1315-6NS71-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS direct starter, 3RK1315-6NS71-0AA0, 4 kW at 400 V, Trip Class 10, IP65, AS-Interface, 4 digital inputs, 159 x 294 x 215 mm.","salesMarkdown":"## What this SIRIUS direct starter does The Siemens 3RK1315-6NS71-0AA0 is a SIRIUS direct starter rated for 4 kW at 400 V and 4 kW at 500 V, with a Trip Class 10 overload protection curve — meaning it trips within 10 seconds at 7.2× rated current, sized for standard induction motor starts without nuisance tripping on normal acceleration. It communicates via AS-Interface (not PROFIBUS or PROFINET) and provides 4 digital inputs for local sensors or pushbuttons, addressed through an M12 plug. ## Supply and control voltage The control supply is 24 V DC nominal, with a permissible range of 20.4 to 28.8 V DC, and a maximum of 31.6 V DC — stay within that window to avoid damaging the AS-Interface electronics. ON-delay is 25 ms, OFF-delay is 35 ms — fast enough for most conveyor and pump sequencing, but not for safety-rated stop categories that need faster break times. ## Environmental limits and mounting Shock rated at 12g for 11 ms, vibration at 7 mm / 2g — it holds up on a vibrating conveyor or crusher frame. Mounting is vertical, horizontal, or flat — screw-fixing through the 294 mm wide × 215 mm high × 159 mm deep body. The main circuit connects via a HAN Q4/2 plug per ISO 23570.","metaTitle":"Siemens 3RK1315-6NS71-0AA0 SIRIUS Direct Starter, 4 kW, IP65","metaDescription":"Siemens SIRIUS 3RK1315-6NS71-0AA0 direct starter, 4 kW at 400 V, Trip Class 10, IP65, AS-Interface, 4 digital inputs. Current lifecycle stage. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"NRND","categoryPath":["Remote I/O & Fieldbus Modules"],"specifications":{"Depth":"159 mm","Width":"294 mm","at DC":"20.4 ... 28.8 V","Height":"215 mm","Trip Class":"CLASS 10","Recommended":"horizontal","Direct Start":"Yes","ON-delay time":"25 ms","During Storage":"-40 ... +70 °C","OFF-delay time":"35 ms","lifecycle_stage":"current","During Operation":"-25 ... +55 °C","During Transport":"-40 ... +70 °C","Fastening Method":"screw fixing","Reverse Starting":"No","Shock Resistance":"12g / 11 ms","Mounting Position":"vertical, horizontal, flat","On-Site Operation":"No","PROFINET protocol":"No","at DC rated value":"20.4 ... 28.8 V","Product Brand Name":"SIRIUS","Type Of Assignment":"1","Degree Of Pollution":"3","Maximum Permissible":"31.6 V","Minimum Permissible":"26.5 V","Product Designation":"Motor starters","protection class IP":"IP65","PROFIBUS DP protocol":"No","Vibration Resistance":"7 mm / 2g","at 400 V rated value":"4 kW","at 500 V rated value":"4 000 W","AS-Interface protocol":"Yes","Design Of The Product":"direct starter","For Device Addressing":"M12 plug","supply voltage 1 at DC":"24 V","For Main Current Circuit":"plug according to ISO 23570, HAN Q4/2","Number Of Digital Inputs":"4","at 220/230 V rated value":"2 hp","at 460/480 V rated value":"5 hp","For Digital Input Signals":"4","Number Of Digital Outputs":"1","For Digital Output Signals":"1","at AC at 400 V rated value":"9 A","brake control with 24 V DC":"No","1 For Digital Input Signals":"M12 socket","2 For Digital Input Signals":"M12 socket","3 For Digital Input Signals":"M12 socket","4 For Digital Input Signals":"M12 socket","brake control with 180 V DC":"No","brake control with 230 V AC":"No","brake control with 400 V AC":"No","brake control with 500 V DC":"No","1 For Digital Output Signals":"M12 socket","For Supply Voltage Line-Side":"M12 plug","In Standby Mode Of Operation":"0.1 A","Type Of The Motor Protection":"full motor protection","at AC-3 at 400 V rated value":"9 A","Operating Voltage Rated Value":"200 ... 440 V","Substance Prohibitance (Date)":"07/01/2006","Digital Inputs Parameterizable":"No","Insulation Voltage Rated Value":"500 V","Design Of The Switching Contact":"solid-state / thyristor / 2 phases","Digital Outputs Parameterizable":"No","For Auxiliary And Control Circuit":"connector","Between Main And Auxiliary Circuit":"400 V","Design Of Short-Circuit Protection":"circuit-breakers","Product Function Bus Communication":"Yes","Relative Humidity During Operation":"10 ... 95 %","supply voltage 1 at DC rated value":"30 V","Product Component Motor Brake Output":"No","Surge Voltage Resistance Rated Value":"6 000 V","Between Control And Auxiliary Circuit":"24 V","EMC immunity according to IEC 60947-1":"corresponds to degree of severity 3, ambience A (industrial sector)","Type Of Voltage Of The Supply Voltage":"DC","due to burst according to IEC 61000-4-4":"2 kV network connection / 1 kV control connection","Number Of Poles For Main Current Circuit":"3","control supply voltage at DC rated value":"20.4 ... 28.8 V","Product Function Short Circuit Protection":"Yes","Touch Protection Against Electrical Shock":"finger-safe","in switching state ON with bypass circuit":"2.1888 W","in switching state OFF with bypass circuit":"1.9584 W","protocol is supported AS-Interface protocol":"Yes","Control Circuit Interface To Parallel Wiring":"No","At The Manufacturer-Specific Device Interface":"optical interface","Type Of Voltage Of The Control Supply Voltage":"DC","EMC emitted interference according to IEC 60947-1":"CISPR11, ambience A (group 2)","Product Extension Braking Module For Brake Control":"No","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","product function control circuit interface with IO link":"No","Type Of Electrical Connection Of The Communication Interface":"M12 plug","full-load current (FLA) for 3-phase AC motor at 480 V rated value":"7.6 A","operating voltage at AC at 60 Hz according to CSA and UL rated value":"480 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"1.5 ... 9 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/bb21b2657d7724978820ec964248abef.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=189603&mlfb=3RK1315-6NS71-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RK1315-6NS71-0AA0/alternatives.json"},"ai":{"faq":[{"question":"What communication protocol does this starter use?","answer":"It uses AS-Interface for control communication; it does not support PROFIBUS DP or PROFINET."},{"question":"What is the IP rating and mounting style?","answer":"IP65 enclosure, screw-fixing to a flat surface, recommended horizontal orientation. Dimensions are 294 mm wide × 215 mm high × 159 mm deep."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RK1315-6NS71-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RK1315-6NS71-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}