{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RK1315-6NS71-1AA3","brand":"Siemens","brandSlug":"siemens","productSlug":"3RK1315-6NS71-1AA3","canonicalUrl":"https://aoctrl.com/siemens/3RK1315-6NS71-1AA3","factsUrl":"https://aoctrl.com/api/mcp/products/3RK1315-6NS71-1AA3","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS reversing starter, 3RK1315-6NS71-1AA3, 4 kW at 400 V, CLASS 10, IP65, AS-Interface, 24 V DC.","salesMarkdown":"Power supply is 24 V DC nominal (20.4 to 28.8 V range), and the control interface is AS-Interface — the unit addresses via an M12 plug. The main current circuit connects through a HAN Q4/2 connector per ISO 23570, so you're looking at a pre-wired, plug-and-play device for the motor leads. Four digital inputs are on board for limit switches, emergency stops, or sensor feedback. ## Panel and machine integration Mounting is screw fixing, and the unit can be installed vertically, horizontally, or flat — so you have flexibility for tight machine frames. The footprint is 294 mm wide, 215 mm high, and 159 mm deep. That's a substantial block; plan your gland plate and cable entry accordingly. Vibration resistance is 2g at 7 mm amplitude, and shock resistance is 12g for 11 ms — it'll hold up on a packaging machine or conveyor drive end.","metaTitle":"Siemens 3RK1315-6NS71-1AA3 SIRIUS Reversing Starter, 4 kW, I","metaDescription":"Siemens SIRIUS 3RK1315-6NS71-1AA3 reversing motor starter. 4 kW at 400 V, CLASS 10 trip, IP65, AS-Interface, 24 V DC. Active production. RFQ for lead time.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"NRND","categoryPath":["Remote I/O & Fieldbus Modules"],"specifications":{"Depth":"159 mm","Width":"294 mm","at DC":"20.4 ... 28.8 V","Height":"215 mm","Trip Class":"CLASS 10","Recommended":"horizontal","Direct Start":"No","ON-delay time":"25 ms","During Storage":"-40 ... +70 °C","OFF-delay time":"35 ms","lifecycle_stage":"current","During Operation":"-25 ... +55 °C","During Transport":"-40 ... +70 °C","Fastening Method":"screw fixing","Reverse Starting":"Yes","Shock Resistance":"12g / 11 ms","Mounting Position":"vertical, horizontal, flat","On-Site Operation":"No","PROFINET protocol":"No","at DC rated value":"20.4 ... 28.8 V","Product Brand Name":"SIRIUS","Type Of Assignment":"1","Degree Of Pollution":"3","Maximum Permissible":"31.6 V","Minimum Permissible":"26.5 V","Product Designation":"Motor starters","protection class IP":"IP65","PROFIBUS DP protocol":"No","Vibration Resistance":"7 mm / 2g","at 400 V rated value":"4 kW","at 500 V rated value":"4 000 W","AS-Interface protocol":"Yes","Design Of The Product":"reversing starter","For Device Addressing":"M12 plug","supply voltage 1 at DC":"24 V","For Main Current Circuit":"plug according to ISO 23570, HAN Q4/2","Number Of Digital Inputs":"4","at 220/230 V rated value":"2 hp","at 460/480 V rated value":"5 hp","For Digital Input Signals":"4","Number Of Digital Outputs":"1","For Digital Output Signals":"1","at AC at 400 V rated value":"9 A","brake control with 24 V DC":"No","1 For Digital Input Signals":"M12 socket","2 For Digital Input Signals":"M12 socket","3 For Digital Input Signals":"M12 socket","4 For Digital Input Signals":"M12 socket","brake control with 180 V DC":"No","brake control with 230 V AC":"Yes","brake control with 400 V AC":"Yes","brake control with 500 V DC":"No","1 For Digital Output Signals":"M12 socket","For Supply Voltage Line-Side":"M12 plug","In Standby Mode Of Operation":"0.1 A","Type Of The Motor Protection":"full motor protection","at AC-3 at 400 V rated value":"9 A","Operating Voltage Rated Value":"200 ... 440 V","Substance Prohibitance (Date)":"07/01/2006","Digital Inputs Parameterizable":"No","Insulation Voltage Rated Value":"500 V","Design Of The Switching Contact":"solid-state / thyristor / 2 phases","Digital Outputs Parameterizable":"No","For Auxiliary And Control Circuit":"connector","Between Main And Auxiliary Circuit":"400 V","Design Of Short-Circuit Protection":"circuit-breakers","Product Function Bus Communication":"Yes","Relative Humidity During Operation":"10 ... 95 %","supply voltage 1 at DC rated value":"30 V","Product Component Motor Brake Output":"Yes","Surge Voltage Resistance Rated Value":"6 000 V","Between Control And Auxiliary Circuit":"24 V","EMC immunity according to IEC 60947-1":"corresponds to degree of severity 3, ambience A (industrial sector)","Type Of Voltage Of The Supply Voltage":"DC","due to burst according to IEC 61000-4-4":"2 kV network connection / 1 kV control connection","Number Of Poles For Main Current Circuit":"3","control supply voltage at DC rated value":"20.4 ... 28.8 V","Product Function Short Circuit Protection":"Yes","Touch Protection Against Electrical Shock":"finger-safe","in switching state ON with bypass circuit":"6.9408 W","in switching state OFF with bypass circuit":"1.9584 W","protocol is supported AS-Interface protocol":"Yes","Control Circuit Interface To Parallel Wiring":"No","At The Manufacturer-Specific Device Interface":"optical interface","Type Of Voltage Of The Control Supply Voltage":"DC","EMC emitted interference according to IEC 60947-1":"CISPR11, ambience A (group 2)","Product Extension Braking Module For Brake Control":"No","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","product function control circuit interface with IO link":"No","Type Of Electrical Connection Of The Communication Interface":"M12 plug","full-load current (FLA) for 3-phase AC motor at 480 V rated value":"7.6 A","operating voltage at AC at 60 Hz according to CSA and UL rated value":"480 V","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"1.5 ... 9 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=335426&mlfb=3RK1315-6NS71-1AA3","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RK1315-6NS71-1AA3/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this reversing starter?","answer":"Rated 4 kW at 400 V, CLASS 10 trip, IP65 enclosure, 24 V DC supply (20.4 to 28.8 V range), AS-Interface protocol, four digital inputs, and dimensions of 294 x 215 x 159 mm (W x H x D)."},{"question":"Does this part drop into a panel designed for a Siemens PLC like the 6ES7517?","answer":"No. The 6ES7517 series are SIMATIC S7-1500 CPUs, not motor starters. They serve completely different functions and have different wiring, mounting, and communication interfaces. This reversing starter is a standalone motor control device, not a PLC module."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RK1315-6NS71-1AA3","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RK1315-6NS71-1AA3 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}