{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RK1325-6LS41-1AA5","brand":"Siemens","brandSlug":"siemens","productSlug":"3RK1325-6LS41-1AA5","canonicalUrl":"https://aoctrl.com/siemens/3RK1325-6LS41-1AA5","factsUrl":"https://aoctrl.com/api/mcp/products/3RK1325-6LS41-1AA5","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS reversing motor starter, 3RK1325-6LS41-1AA5, IP65, AS-Interface, 5.5 kW at 400 V, trip classes 5/10/15/20.","salesMarkdown":"## SIRIUS reversing starter — panel-mount, AS-Interface controlled The Siemens 3RK1325-6LS41-1AA5 is a SIRIUS reversing motor starter in an IP65 enclosure, rated 5.5 kW at 400 V and configurable for trip classes 5, 10, 15, or 20. It communicates via AS-Interface protocol, addressed through an M12 plug, and accepts a 24 V DC supply (20.4–28.8 V range). The unit is screw-fixed into the panel and can be mounted vertically, horizontally, or flat — the manufacturer recommends horizontal orientation for best thermal performance. The 5.5 kW rating at 400 V AC-3 duty tells you the starter can switch a 3-phase induction motor of that output under normal starting conditions; the same unit also carries ratings of 3 hp at 230 V, 7.5 hp at 480 V, and 10 hp at 600 V for North American line voltages. Trip class selection (5, 10, 15, 20) sets the thermal overload curve — class 10 matches standard motor protection for most pumps and fans; class 20 allows longer inrush for high-inertia loads like centrifuges. The reversing function means two contactors are interlocked inside the same housing, so a single command flips motor rotation without external interlocking wiring. The AS-Interface connection carries both power and data on a single two-wire cable, reducing field wiring compared to a parallel I/O run. Four digital inputs are available on the module for local limit switches or pushbuttons. ## Mechanical fit and environmental limits Dimensions are 294 mm wide, 215 mm tall, and 159 mm deep — this is a wide-format reversing starter, so verify DIN-rail clearance or backplate space before committing. Screw fixing is the only fastening method; no snap-on DIN rail clip is used. Shock resistance is rated at 12g for 11 ms, and vibration resistance at 7 mm / 2g — adequate for most industrial machinery but check against your specific machine's environment. ## Switching times and pollution degree ON-delay is 85 ms, OFF-delay is 65 ms — these are the internal response times from command to main contact closure. The maximum permissible supply voltage is 31.6 V DC, with a minimum of 26.5 V DC for reliable operation.","metaTitle":"Siemens 3RK1325-6LS41-1AA5 SIRIUS Reversing Starter, 5.5 kW","metaDescription":"Siemens 3RK1325-6LS41-1AA5 SIRIUS reversing motor starter. IP65, AS-Interface, trip class 5-20. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"NRND","categoryPath":["Remote I/O & Fieldbus Modules"],"specifications":{"Depth":"159 mm","Width":"294 mm","at DC":"20.4 ... 28.8 V","Height":"215 mm","Trip Class":"CLASS 5, 10, 15, 20","Recommended":"horizontal","Direct Start":"No","ON-delay time":"85 ms","During Storage":"-40 ... +70 °C","OFF-delay time":"65 ms","lifecycle_stage":"current","During Operation":"-25 ... +55 °C","During Transport":"-40 ... +70 °C","Fastening Method":"screw fixing","Reverse Starting":"Yes","Shock Resistance":"12g / 11 ms","Mounting Position":"vertical, horizontal, flat","On-Site Operation":"No","PROFINET protocol":"No","at DC rated value":"20.4 ... 28.8 V","Product Brand Name":"SIRIUS","Type Of Assignment":"1","Degree Of Pollution":"3","Maximum Permissible":"31.6 V","Minimum Permissible":"26.5 V","Product Designation":"Motor starters","protection class IP":"IP65","PROFIBUS DP protocol":"No","Vibration Resistance":"7 mm / 2g","at 400 V rated value":"5.5 kW","at 500 V rated value":"5 500 W","AS-Interface protocol":"Yes","Design Of The Product":"reversing starter","For Device Addressing":"M12 plug","supply voltage 1 at DC":"24 V","For Main Current Circuit":"plug according to ISO 23570, HAN Q4/2","Number Of Digital Inputs":"4","at 220/230 V rated value":"3 hp","at 460/480 V rated value":"7.5 hp","at 575/600 V rated value":"10 hp","For Digital Input Signals":"4","Number Of Digital Outputs":"1","For Digital Output Signals":"1","at AC at 400 V rated value":"12 A","brake control with 24 V DC":"No","1 For Digital Input Signals":"M12 socket","2 For Digital Input Signals":"M12 socket","3 For Digital Input Signals":"M12 socket","4 For Digital Input Signals":"M12 socket","brake control with 180 V DC":"Yes","brake control with 230 V AC":"No","brake control with 400 V AC":"No","brake control with 500 V DC":"No","1 For Digital Output Signals":"M12 socket","For Supply Voltage Line-Side":"M12 plug","In Standby Mode Of Operation":"0.1 A","Type Of The Motor Protection":"full motor protection","at AC-3 at 400 V rated value":"12 A","Operating Voltage Rated Value":"200 ... 440 V","Substance Prohibitance (Date)":"07/01/2006","Digital Inputs Parameterizable":"Yes","Insulation Voltage Rated Value":"500 V","Design Of The Switching Contact":"electromechanical","Digital Outputs Parameterizable":"Yes","For Auxiliary And Control Circuit":"connector","Between Main And Auxiliary Circuit":"400 V","Design Of Short-Circuit Protection":"circuit-breakers","Product Function Bus Communication":"Yes","Relative Humidity During Operation":"10 ... 95 %","supply voltage 1 at DC rated value":"30 V","Product Component Motor Brake Output":"Yes","Surge Voltage Resistance Rated Value":"6 000 V","Between Control And Auxiliary Circuit":"24 V","EMC immunity according to IEC 60947-1":"corresponds to degree of severity 3, ambience A (industrial sector)","Type Of Voltage Of The Supply Voltage":"DC","due to burst according to IEC 61000-4-4":"2 kV network connection / 1 kV control connection","Number Of Poles For Main Current Circuit":"3","control supply voltage at DC rated value":"20.4 ... 28.8 V","Product Function Short Circuit Protection":"Yes","Touch Protection Against Electrical Shock":"finger-safe","in switching state ON with bypass circuit":"4.1184 W","in switching state OFF with bypass circuit":"2.0736 W","protocol is supported AS-Interface protocol":"Yes","Control Circuit Interface To Parallel Wiring":"No","At The Manufacturer-Specific Device Interface":"optical interface","Type Of Voltage Of The Control Supply Voltage":"DC","EMC emitted interference according to IEC 60947-1":"CISPR11, ambience A (industrial sector)","Product Extension Braking Module For Brake Control":"No","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","product function control circuit interface with IO link":"No","Type Of Electrical Connection Of The Communication Interface":"M12 plug","full-load current (FLA) for 3-phase AC motor at 480 V rated value":"11 A","operating voltage at AC at 60 Hz according to CSA and UL rated value":"600 V","Mechanical Service Life (Switching Cycles) Of The Main Contacts Typical":"10 000 000","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"1.5 ... 12 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9cb618114fd9a8946d01be39494ba8d5.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=107786&mlfb=3RK1325-6LS41-1AA5","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RK1325-6LS41-1AA5/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RK1325-6LS41-1AA5 and get current pricing?","answer":"This part is sourced to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What does the IP65 rating mean for this reversing starter?","answer":"IP65 means dust-tight and protected against low-pressure water jets — suitable for washdown areas or outdoor panels without an additional enclosure."},{"question":"What trip classes are available on 3RK1325-6LS41-1AA5?","answer":"The starter is configurable for trip classes 5, 10, 15, or 20, selected to match the motor's thermal characteristics."},{"question":"What communication protocol does this starter use?","answer":"It uses AS-Interface protocol, addressed via an M12 plug, carrying both power and data on a single two-wire cable."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RK1325-6LS41-1AA5","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RK1325-6LS41-1AA5 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}