{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RK1335-0AS01-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RK1335-0AS01-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3RK1335-0AS01-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3RK1335-0AS01-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3RK1335-0AS01-0AA0 — now in phase-out and being discontinued. Supplied from remaining channel stock; full specifications, lifecycle and same-series options are below.","salesMarkdown":"## Overview The 3RK1335-0AS01-0AA0 is a Siemens SIRIUS M200D communication module for PROFINET, order code 3RK1335-0AS01-0AA0, providing the network interface for M200D motor starters. It carries two M12 bus connectors with loop-through and two 7/8\" power connectors for 24 V DC supply, all housed in an IP65 enclosure for direct machine-mount installation. This module acts as the PROFINET gateway for a SIRIUS M200D motor starter cluster. The two M12 bus connectors provide a loop-through topology — the incoming PROFINET cable connects to one port, and the second port feeds the next device in the line, simplifying cabling on multi-motor assemblies. The 24 V DC supply enters through the 7/8\" connectors, also looped through, so a single power drop can feed several starters. Rated IP65, the module withstands washdown and dust exposure common on conveyor and packaging lines. The 12g / 11 ms shock rating means it survives the vibration and impact typical of machine-mounted installations without losing connection. ## Applications M200D communication modules are used in distributed motor control applications — conveyor systems, packaging machinery, material handling, and pump stations — where the motor starter is mounted close to the motor rather than in a central cabinet. The PROFINET interface integrates with Siemens controllers over industrial Ethernet. Siemens has classified the 3RK1335-0AS01-0AA0 as phase-out, with a discontinuation date of 2025-08-01. After that date, Siemens will no longer manufacture or support the module. Buyers should evaluate last-time-buy quantities or consider the successor technology module (3RK1395*) that the product description references as compatible. Sourcing through surplus or broker channels may be necessary after the cut-off.","metaTitle":"Siemens 3RK1335-0AS01-0AA0 M200D PROFINET Communication Module","metaDescription":"Siemens SIRIUS M200D communication module 3RK1335-0AS01-0AA0 for PROFINET, IP65, 24 V DC, 2x M12, 2x 7/8\", phase-out 2025-08-01.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"NRND","categoryPath":["Remote I/O & Fieldbus Modules"],"specifications":{"Depth":"32mm","Width":"174mm","Height":"139mm","During Storage":"-40 ... +70°C","lifecycle_stage":"current","During Operation":"-25 ... +55°C","During Transport":"-40 ... +70°C","Fastening Method":"screw fixing","Shock Resistance":"12g / 11 ms","Mounting Position":"vertical, horizontal, flat","at DC rated value":"24V","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"Communication module","protection class IP":"IP65","Vibration Resistance":"7 mm / 2g","Design Of The Product":"communication module","Mounting Position Recommended":"horizontal","For Communication Transmission":"M12 socket","Insulation Voltage Rated Value":"30V","For Auxiliary And Control Circuit":"connector","Product Function Bus Communication":"Yes","Relative Humidity During Operation":"10 ... 95%","Surge Voltage Resistance Rated Value":"800V","EMC immunity according to IEC 60947-1":"corresponds to degree of severity 3, ambience A (industrial sector)","Type Of Voltage Of The Supply Voltage":"DC","at DC rated value maximum permissible":"28.8V","at DC rated value minimum permissible":"20.4V","control circuit interface with IO link":"No","reference code according to EN 61346-2":"Q","protocol is supported PROFINET protocol":"Yes","protocol is supported PROFIBUS DP protocol":"No","protocol is supported AS-Interface protocol":"No","Control Circuit Interface To Parallel Wiring":"No","design of the interface PROFIBUS DP protocol":"No","Type Of Voltage Of The Control Supply Voltage":"DC","design of the interface AS-Interface protocol":"No","EMC emitted interference according to IEC 60947-1":"CISPR11, ambience A (industrial sector)","Installation Altitude At Height Above Sea Level Maximum":"2 000m","Type Of Electrical Connection Of The Communication Interface":"M12 socket"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$194.31","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=227737&mlfb=3RK1335-0AS01-0AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RK1335-0AS01-0AA0/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RK1335-0AS01-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RK1335-0AS01-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}