{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RK1395-6KS41-3AD5-Z E09","brand":"Siemens","brandSlug":"siemens","productSlug":"3RK1395-6KS41-3AD5-Z-E09","canonicalUrl":"https://aoctrl.com/siemens/3RK1395-6KS41-3AD5-Z-E09","factsUrl":"https://aoctrl.com/api/mcp/products/3RK1395-6KS41-3AD5-Z%20E09","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS M200D reversing starter, 3RK1395-6KS41-3AD5-Z E09, AC-3 0.75 kW / 400 V, 0.15–2.00 A, electronic OL, 4 DI / 2 DO, Han Q4/2–Q8/0, PROFIBUS/PROFINET, NRND.","salesMarkdown":"The Siemens 3RK1395-6KS41-3AD5-Z E09 is a SIRIUS M200D technology module configured as a reversing starter. It switches motor loads under AC-3 duty at 0.75 kW on a 400 V three-phase line, with the adjustable current range set between 0.15 A and 2.00 A. Electronic overload protection is onboard, and the module accepts THERMOCLICK or PTC thermistor inputs for motor temperature monitoring. The unit includes a brake contact rated for 180 V DC, plus 4 digital inputs and 2 digital outputs. Connectivity is via Han Q4/2 and Han Q8/0 mixed-power/data connectors, and the module communicates over PROFIBUS or PROFINET when paired with a 3RK1305* communication module. Manual on-site operation is provided, along with a key-operated switch (CES locking system) to prevent unauthorized access. This makes the starter suited for safety-guarded machinery where local lockout is required. The AC-3 rating at 0.75 kW / 400 V defines the motor switching capability for squirrel-cage induction motors — the dominant load type in conveyors, pumps, and fans. The 0.15–2.00 A adjustment range means it covers small motors up to roughly 0.75 kW at 400 V; if your motor draws above 2.00 A full-load, this starter is undersized. Electronic overload protection with THERMOCLICK/PTC input means the module reads motor thermistor directly, tripping on overtemperature rather than relying solely on thermal replica curves. This is useful for motors in high-duty-cycle or frequent-start applications where I²t models lag. The 180 V DC brake contact handles DC injection brakes common on small reversing drives. The 4 DI / 2 DO count supports local start/stop, interlock, and status feedback without an extra I/O block. The Han Q4/2 and Han Q8/0 connectors carry both power and fieldbus in a single hybrid cable, reducing wiring time compared to separate motor and network runs. Because it requires a 3RK1305* communication module for PROFIBUS or PROFINET, the system integrator must account for that additional component in the BOM. The key-operated CES lock satisfies machinery directive requirements for local isolation on safety circuits.","metaTitle":"Siemens 3RK1395-6KS41-3AD5-Z E09 M200D Reversing Starter, NR","metaDescription":"Siemens SIRIUS M200D reversing starter, 0.75 kW at 400 V, 0.15–2.00 A, electronic OL, PROFIBUS/PROFINET. NRND status — sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"NRND","categoryPath":["Remote I/O & Fieldbus Modules"],"specifications":{"Group Code":"R711","Product Group":"3722","Product class":"A: Standard product which is a stock item could be returned within the returns guidelines/period.","Quantity Unit":"1 Piece","Product Family":"Ordering Data Overview","lifecycle_stage":"current","Packaging Quantity":"1","Export Control Regulations":"AL : N / ECCN : 9N9999","Packaging dimensions (L x W x H)":"377.00 x 287.00 x 221.00 mm","Compliance with the substance restrictions according to RoHS directive":"Since: 01-07-06","REACH Art. 33 Duty to inform according to the current list of candidates":"Lead CAS-No. 7439-92-1 > 0,1 % (w / w)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/319ab7f3506bbe41f584de39bd8d8584.pdf","sourceUrl":"https://sieportal.siemens.com/en-ae/products-services/detail/3RK1395-6KS41-3AD5-ZE09?tree=CatalogTree","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RK1395-6KS41-3AD5-Z%20E09/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation is available for this part?","answer":"RoHS compliance is declared effective July 1, 2006. The part contains lead above 0.1% by weight (CAS 7439-92-1), declared under REACH Article 33. Export control classification is AL: N / ECCN: 9N9999."},{"question":"What is the group code and product group for this component?","answer":"The group code is R711 and the product group is 3722."},{"question":"What are the key functional ratings of this reversing starter?","answer":"It is rated AC-3 at 0.75 kW / 400 V with an adjustable current range of 0.15 A to 2.00 A. It includes electronic overload protection with THERMOCLICK/PTC input, a 180 V DC brake contact, 4 digital inputs, and 2 digital outputs. Connectivity is via Han Q4/2 and Han Q8/0 connectors."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RK1395-6KS41-3AD5-Z-E09","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RK1395-6KS41-3AD5-Z-E09 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}